3RA1423-8XC21-1AC2 - CONTACTOR COMBINATION, STAR-DELTA (PREASSEMBLED) FRONT-MOUNTED ON TIME RELAY, AC-3 11KW/400 V, 3-POLE, SIZE S0,S0,S0, EL.LOCK. DEVICE, SCREW CONNECTION, AC 24V, 50/60HZ (siemens) - Quad Industry GmbH

Артикул: 3RA1423-8XC21-1AC2
Наименование: CONTACTOR COMBINATION, STAR-DELTA (PREASSEMBLED) FRONT-MOUNTED ON TIME RELAY, AC-3 11KW/400 V, 3-POLE, SIZE S0,S0,S0, EL.LOCK. DEVICE, SCREW CONNECTION, AC 24V, 50/60HZ (siemens)
Производитель: Siemens


Наименование продукта
CONTACTOR COMBINATION, STAR-DELTA (PREASSEMBLED) FRONT-MOUNTED ON TIME RELAY, AC-3 11KW/400 V, 3-POLE, SIZE S0,S0,S0, EL.LOCK. DEVICE, SCREW CONNECTION, AC 24V, 50/60HZ
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2001-01-01
CONTACTOR COMBINATION, STAR-DELTA (PREASSEMBLED) FRONT-MOUNTED ON TIME RELAY, AC-3 11KW/400 V, 3-POLE, SIZE S0,S0,S0, EL.LOCK. DEVICE, SCREW CONNECTION, AC 24V, 50/60HZ
 
General details:
product brand name   SIRIUS
product designation   contactor assembly
Product function   wye-delta-contactor
Size of the contactor   S0, S0, S0
Protection class IP / on the front   IP20
Degree of pollution   3
Insulation voltage / with degree of pollution 3 / rated value V 690
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature    
  • during operating
°C -25 +60
  • during storage
°C -55 +80
  • during transport
°C -55 +80
Item designation    
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  K
  • according to DIN EN 61346-2
  Q
Mechanical operating cycles as operating time    
  • of the main contacts / typical
  10,000,000
  • of the auxiliary contacts / typical
  10,000,000
  • of the contactor with added auxiliary switch block / typical
  10,000,000
 
Main circuit:
Number of poles / for main current circuit   3
Number of NC contacts / for main contacts   0
Operating voltage / at AC-3 / rated value / maximum V 690
Operating current / at AC-3 / at 400 V / rated value A 25
Service power / at AC-3    
  • at 400 V / rated value
kW 11
  • at 500 V / rated value
kW 15.6
  • at 690 V / rated value
kW 19
 
Steuerstromkreis/Ansteuerung:
Design of activation   conventional
Design of the surge suppressor   without
Type of voltage / of the controlled supply voltage   AC
Control supply voltage frequency    
  • 1 / rated value
Hz 50
  • 2 / rated value
Hz 60
Control supply voltage / 1    
  • at 50 Hz / for AC / rated value
V 24
  • at 60 Hz / for AC / rated value
V 24
operating range factor control supply voltage rated value / of the magnet coil    
  • at 50 Hz
   
  • for AC
  0.8 1.1
  • at 60 Hz
   
  • for AC
  0.85 1.1
  • for DC
  0.8 1.1
 
Auxiliary circuit:
Product extension / auxiliary switch   Yes
Number of NC contacts / for auxiliary contacts    
  • instantaneous switching
  4
  • lagging switching
  0
Number of NO contacts / for auxiliary contacts    
  • instantaneous switching
  4
  • leading switching
  0
 
Short-circuit:
   
Design of the fuse link    
  • for short-circuit protection of the auxiliary switch / required
  fuse gL/gG: 10 A
  • for short-circuit protection of the main circuit
   
  • with type of assignment 1 / required
  fuse gL/gG: 63 A
  • at type of coordination 2 / required
  fuse gL/gG: 25 A
 
Einbau/Befestigung/Abmessung:
   
Built in orientation   with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back
Type of mounting   screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Width mm 158
Height mm 88
Depth mm 135
Distance, to be maintained, to the ranks assembly / sidewards mm 0
Distance, to be maintained, to earthed part / sidewards mm 0
Distance, to be maintained, conductive elements    
  • sidewards
mm 0
 
Anschlüsse/Klemmen
Design of the electrical connection / for main current circuit   screw-type terminals
 
Approbationen/ Zertifikate
   
Verification of suitability   CE / UL / CCC / GL / LRS / BV / DNV / RMRS / RINA / PRS / ABS
General Product Approval Declaration of Conformity
GOST EC-Declaration of Conformity        
Shipping Approval
BV / Bureau Veritas GL / Germanischer Lloyd LRS / Lloyds Register of Shipping RINA / Registro Italiano Navale RMRS / Russian Maritime Register  
other
Confirmation other Environmental Confirmations      
 
Sicherheitstechnische Merkmale
   
Contact reliability / of the auxiliary contacts   1 faulty switching per 100 million (17 V, 1 mA)
 
Further information:
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrial-controls/mall
CAx-Online-Generator
http://www.siemens.com/cax
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
http://support.automation.siemens.com/WW/view/en/3RA1423-8XC21-1AC2/all
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RA1423-8XC21-1AC2
 