21AD0
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
21AD014GJAYNAND0NNNN-ND-B0-C1-P6-S12
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 14 Amps (014), 10 HP Normal Duty, NEMA Type 12 (G), Door Mounted N4X/12 Full Numeric LCD HIM, NEMA 12 (J), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6), 800F Drive Alarm P.L. (-S12)
|
Allen-Bradley
|
|
21AD022A3AYNADC0NNNN-HD-B0-C1-J1-P3
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), DeviceNET - DPI Module (D), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power On Aux. Contact (-J1), Control Power for program options only (-C1), Drive Circuit Breaker (-P3)
|
Allen-Bradley
|
|
21AD022A3AYNADC0NNNN-ND-B0-C1-L1-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), DeviceNET - DPI Module (D), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), No Input Protection (-P1), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
|
21AD022A3AYNADD0NNNN-ND-B0-C1-L1-P6-S1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), DeviceNET - DPI Module (D), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
|
21AD022A3AYNAED0NNNN-HD-B0-C5-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), Ethernet/IP - DPI Module (E), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), No Input Protection (-P1)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-HD-B0-C1-L2-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), No Input Protection (-P1), Line Reactor, Mtd & Wired, 3%, Output (-L2)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-HD-B0-C1-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), No Input Protection (-P1)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-HD-B0-C1-P3
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-HD-B0-C1-P6-S1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-HD-B0-C1-P6-S1-S9
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1), 800F Run P.L. (-S9)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-HD-B0-C5-P2
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), Drive Input Fuses (-P2)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-ND-B0-C1-L1-L2-P3
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3), Line Reactor, Mtd & Wired, 3%, Input (-L1), Line Reactor, Mtd & Wired, 3%, Output (-L2)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-ND-B0-C1-L1-P6
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-ND-B0-C1-P3
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-ND-B0-C1-P3-P11
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3), Drive Input Contactor (-P11)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-ND-B0-C1-P6
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6)
|
Allen-Bradley
|
|
21AD022A3AYNANC0NNNN-ND-B0-C5-P6
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), Drive Disconnect Switch (-P6)
|
Allen-Bradley
|
|
21AD022A3AYNANC1NNNN-HD-B0-C1-L2-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, with Encoder (1), No Bypass (-B0), Control Power for program options only (-C1), No Input Protection (-P1), Line Reactor, Mtd & Wired, 3%, Output (-L2)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-HD-B0-C1-J4-M3-P6
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Drive Run Aux. Contact (-J4), Control Power for program options only (-C1), Drive/Bypass Motor Run Time Meter (M3), Drive Disconnect Switch (-P6)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-HD-B0-C1-L1-P3-S18
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3), 800F Speed Pot - 1 Turn (-S18), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-HD-B0-C1-L1-P6
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Disconnect Switch (-P6), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-HD-B0-C1-L2-P3-S1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1), Line Reactor, Mtd & Wired, 3%, Output (-L2)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-HD-B0-C5-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 10 HP Heavy Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), No Input Protection (-P1)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-ND-B0-C1-J2-J4-P6
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Drive Fault Aux. Contact (-J2), Drive Run Aux. Contact (-J4), Control Power for program options only (-C1), Drive Disconnect Switch (-P6)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-ND-B0-C1-L1-P3
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-ND-B0-C1-L2-P2
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Input Fuses (-P2), Line Reactor, Mtd & Wired, 3%, Output (-L2)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-ND-B0-C1-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), No Input Protection (-P1)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-ND-B0-C1-P3
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), Drive Circuit Breaker (-P3)
|
Allen-Bradley
|
|
21AD022A3AYNAND0NNNN-ND-B0-C5-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), No Input Protection (-P1)
|
Allen-Bradley
|
|
21AD022A3AYNAPC0NNNN-ND-B0-C1-L1-P1
|
PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 22 Amps (022), 15 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), Second Environment Filter per CE EMC directive (89/336/EEC) (A), Profibus DP (P), Enhanced Control 24VDC Basic I/O (C), Enhanced Control, without Encoder (0), No Bypass (-B0), Control Power for program options only (-C1), No Input Protection (-P1), Line Reactor, Mtd & Wired, 3%, Input (-L1)
|
Allen-Bradley
|
Òîâàðû
301 - 330 èç 1214
Íà÷àëî
|
Ïðåä.
|
9
10
11
12
13
|
Ñëåä. |
Êîíåö
|