21AD8P0A3AYNNND0NNNN-ND-B0-C5-L1-P1-S1-S9-S10 - PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 8 Amps (8P0), 5 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), without CE compliant filter (N), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), No Input Protection (-P1), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1), 800F Run P.L. (-S9), 800F Drive Fault P.L. (-S10), Line Reactor, Mtd & Wired, 3%, Input (-L1) - Quad Industry GmbH

Артикул: 21AD8P0A3AYNNND0NNNN-ND-B0-C5-L1-P1-S1-S9-S10
Наименование: PowerFlex70 AC Configured Drive, 480 VAC, 3 PH (D), 8 Amps (8P0), 5 HP Normal Duty, IP20 / NEMA Type 1 (A), LCD Display, Full Numeric Keypad (3), Brake IGBT Installed (Y), Without Drive Mounted Brake Resistor (N), without CE compliant filter (N), No Communication Module (N), Enhanced Control 115VAC Basic I/O (D), Enhanced Control, without Encoder (0), No Bypass (-B0), User Supplied 120VAC Control Power (-C5), No Input Protection (-P1), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1), 800F Run P.L. (-S9), 800F Drive Fault P.L. (-S10), Line Reactor, Mtd & Wired, 3%, Input (-L1)
Производитель: Allen-Bradley




BASE DRIVE INFORMATION
Input Voltage
480 VAC, 3 PH (D)
Drive Duty Cycle
Normal Duty Cycle (-ND)
Current Rating
8 Amps (8P0)
Enclosure
IP20 / NEMA Type 1 (A)
Frame Size
Frame Size B
Please Note:
Any photos in this documentation are representative of the products supplied and may not be that of the actual unit shipping
INSTALLED OPTIONS
Human Interface Module
LCD Display, Full Numeric Keypad (3)
Documentation
User Manual (A)
Brake IGBT
Brake IGBT Installed (Y)
Brake Resistor
Without Drive Mounted Brake Resistor (N)
Filter Options
without CE compliant filter (N)
Internal Communication Module
No Communication Module (N)
Control and I/O
Enhanced Control 115VAC Basic I/O (D)
Feedback option
Enhanced Control, without Encoder (0)
SYSTEM OPTIONS
Bypass Options
No Bypass (-B0)
Input Power Devices
No Input Protection (-P1)
Power Filtering
Line Reactor, Mtd & Wired, 3%, Input (-L1)
Control Power
User Supplied 120VAC Control Power (-C5)
Operator Devices
800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1)
800F Run P.L. (-S9)
800F Drive Fault P.L. (-S10)






Specification Sheet
Configured Drive Storage Instructions
Dimension Drawing (DWG)
Dimension Drawing (PDF)


21AD8P0A3AYNNND0NNNNNDB0C5L1P1S1S9S10
21AD8-P0A3A-YNNND0NNNNNDB0C5L1P1S1S9S10
21A-D8P0A3AYNNND0NNNNNDB0C5L1P1S1S9S10
21AD8 P0A3A YNNND0NNNNNDB0C5L1P1S1S9S10
21A D8P0A3AYNNND0NNNNNDB0C5L1P1S1S9S10

Назад в раздел