1SBT1

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
1SBT172000R9945 CS2000-9945 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT172000R9944 CS2000-9944 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT172000R0004 CS2000BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT172000R0003 CS2000BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R9943 CS1000-9943 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R9942 CS1000-9942 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R9941 CS1000-9941 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R9940 CS1000-9940 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R0004 CS1000BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R0003 CS1000BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R0002 CS1000BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT171000R0001 CS1000BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170503R0004 CS503BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170503R0003 CS503BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170503R0002 CS503BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170503R0001 CS503BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170500R9913 CS500-9913 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170500R0004 CS500BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170500R0003 CS500BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170500R0002 CS500BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170500R0001 CS500BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170300R0004 CS300BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170300R0003 CS300BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170300R0002 CS300BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT170300R0001 CS300BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.) ABB
1SBT130100R0002 EL100P2BB (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Primary bar included. Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT130100R0001 EL100P2 (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor (the temperature of the primary conductor in contact with the case must not exceed 100 °C) Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT191000R9888 ESM1000-9888 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT191000R9887 ESM1000-9887 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT191000R9886 ESM1000-9886 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT191000R0003 ESM1000C (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT191000R0002 ESM1000S (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT191000R0001 ESM1000F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT152000R8000 ES2000-8000 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT152000R0003 ES2000C (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R9680 ES1000-9680 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R9679 ES1000-9679 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R9678 ES1000-9678 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R9677 ES1000-9677 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R9676 ES1000-9676 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R9675 ES1000-9675 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R0003 ES1000S (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R0002 ES1000F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT151000R0001 ES1000C (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150500R9674 ES500-9674 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150500R9673 ES500-9673 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150500R9672 ES500-9672 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150500R0003 ES500S (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150500R0002 ES500F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150500R0001 ES500C (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150300R0003 ES300S (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150300R0002 ES300F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150300R0001 ES300C (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150100R0002 ES100F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT150100R0001 ES100C (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT135100R0001 EL50P1 (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor (the temperature of the primary conductor in contact with the case must not exceed 100 °C) Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT135100R0004 EL55P2BB (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Primary bar included. Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT135100R0002 EL55P2 (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor (the temperature of the primary conductor in contact with the case must not exceed 100 °C) Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT135100R0003 EL50P1BB (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Primary bar included. Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT132500R0002 EL25P1BB (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Primary bar included. Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT132500R0001 EL25P1 (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor (the temperature of the primary conductor in contact with the case must not exceed 100 °C) Secondary connection: 3 soldering pins. Suitable for PCB mounting.) ABB
1SBT152000R0002 ES2000S (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT152000R0001 ES2000F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT152000R9725 ES2000-9725 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.) ABB
1SBT160050R0001 VS50B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT160500R0001 VS500B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT161000R0001 VS1000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT161500R0001 VS1500B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT160125R0001 VS125B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT160250R0001 VS250B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT162000R0001 VS2000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT164200R0001 VS4200B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT164000R0001 VS4000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.) ABB
1SBT163000R0001 VS3000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.) ABB

Òîâàðû 1 - 74 èç 74