Êàòàëîã Abb
EM0
EM01
EM010
EM010
Àðòèêóë
Íàèìåíîâàíèå
Ïðîèçâîäèòåëü
EM010-9394
EM010-9394 (Sensor for AC, DC or pulsating voltage measurement. The EM010 range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. The internal electrostatic screen between the primary and secondary is linked to the terminal "E". The heatsink for the integrated input resistance RE is connected to the marked earth terminal marked on the sensor. Protection of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2.8 N.m. The primary resistance R is made up of the integrated input resistance RE in series with the resistance RP of the primary winding: R = RE + RP. Options: - Other connection types - Other temperature operating ranges. For other options please contact us. Suitable for Industrial and Railway applications.)
ABB
EM010-9320
EM010-9320 (Sensor for AC, DC or pulsating voltage measurement. The EM010 range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. The internal electrostatic screen between the primary and secondary is linked to the terminal "E". The heatsink for the integrated input resistance RE is connected to the marked earth terminal marked on the sensor. Protection of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2.8 N.m. The primary resistance R is made up of the integrated input resistance RE in series with the resistance RP of the primary winding: R = RE + RP. Options: - Other connection types - Other temperature operating ranges. For other options please contact us. Suitable for Industrial and Railway applications.)
ABB
EM010-9239
EM010-9239 (Sensor for AC, DC or pulsating voltage measurement. The EM010 range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. The internal electrostatic screen between the primary and secondary is linked to the terminal "E". The heatsink for the integrated input resistance RE is connected to the marked earth terminal marked on the sensor. Protection of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2.8 N.m. The primary resistance R is made up of the integrated input resistance RE in series with the resistance RP of the primary winding: R = RE + RP. Options: - Other connection types - Other temperature operating ranges. For other options please contact us. Suitable for Industrial and Railway applications.)
ABB
EM010-9238
EM010-9238 (Sensor for AC, DC or pulsating voltage measurement. The EM010 range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. The internal electrostatic screen between the primary and secondary is linked to the terminal "E". The heatsink for the integrated input resistance RE is connected to the marked earth terminal marked on the sensor. Protection of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2.8 N.m. The primary resistance R is made up of the integrated input resistance RE in series with the resistance RP of the primary winding: R = RE + RP. Options: - Other connection types - Other temperature operating ranges. For other options please contact us. Suitable for Industrial and Railway applications.)
ABB
EM010-9237
EM010-9237 (Sensor for AC, DC or pulsating voltage measurement. The EM010 range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. The internal electrostatic screen between the primary and secondary is linked to the terminal "E". The heatsink for the integrated input resistance RE is connected to the marked earth terminal marked on the sensor. Protection of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2.8 N.m. The primary resistance R is made up of the integrated input resistance RE in series with the resistance RP of the primary winding: R = RE + RP. Options: - Other connection types - Other temperature operating ranges. For other options please contact us. Suitable for Industrial and Railway applications.)
ABB