7TCA1
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TCA119130R0040
|
EM FLUO FIT- 5W.+PLATE 2X36W
|
ABB
|
|
7TCA119130R0039
|
EM FLUO FIT- 5W.+PLATE 2X18W
|
ABB
|
|
7TCA119130R0038
|
EM FLUO FIT- 5W.+PLATE-1X58W
|
ABB
|
|
7TCA119130R0037
|
EM FLUO FIT- 5W.+PLATE-1X36W
|
ABB
|
|
7TCA119130R0036
|
EM FLUO FIT- 5W.+PLATE 1X18W
|
ABB
|
|
7TCA119130R0035
|
EM FLUO FIT-5 WIRES2X18W (Emergency fluorescent fixture, 5 wire loop - 2x18W - electronic ballast 110-260V 50-60Hz - 3hr battery - self test - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0034
|
EM FLUO FIT-5 WIRES1X58W (Emergency fluorescent fixture, 5 wire loop - 1x58W - electronic ballast 110-260V 50-60Hz - 3hr battery - self test - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - LCIE15 ATEX 1010X, IECEx LCIE 15.0018X, II 3 GD, Ex nA IICT4 Gc, Ex tc IIIC T65Dc (-40C to +40C), Ex nA IIC T3 Gc, Ex tc IIIC T85Dc (-40C to +60C) IP66)
|
ABB
|
|
7TCA119130R0033
|
EM FLUO FIT-5 WIRES-1X36W (Emergency fluorescent fixture, 5 wire loop - 1x36W - electronic ballast 110-260V 50-60Hz - 3hr battery - self test - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0032
|
EM FLUO FIT-5 WIRES1X18W (Emergency fluorescent fixture, 5 wire loop - 1x18W - electronic ballast 110-260V 50-60Hz - 3hr battery - self test - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0031
|
EM FLUO FIT-5 WIRES2X58W (Emergency fluorescent fixture, 5 wire loop - 2x58W - electronic ballast 110- 260V 50-60Hz - 3hr battery - self test- includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - LCIE15 ATEX 1010X, IECEx LCIE 15.0018X, II 3 GD, Ex nA IICT4 Gc, Ex tc IIIC T65Dc (-40C to +40C), Ex nA IIC T3 Gc, Ex tc IIIC T85Dc (-40C to +60C) IP66)
|
ABB
|
|
7TCA119130R0030
|
EM FLUO FIT- 5W.-PLATE-1X58W (Emergency fluorescent fixture, 5 wire loop - continuity plate - 1x58W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nickel-plated brass M20 cable gland diam 6-12mm/8 5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - LCIE15 ATEX 1010X, IECEx LCIE 15 0018X, II 3 GD, Ex nA IICT4 Gc, Ex tc IIIC T65Dc (-40C to -40C), Ex nA IIC T3 Gc, Ex tc IIIC T85Dc (-40C to -60C) IP66)
|
ABB
|
|
7TCA119130R0029
|
EM FLUO FIT- 5W.-PLATE-2X58W (Emergency fluorescent fixture, 5 wire loop - continuity plate - 2x58W - electronic ballast 220- 240V 50-60Hz - 3hr battery - includes - one nickel-plated brass M20 cable gland diam 6-12mm/8 5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - LCIE15 ATEX 1010X, IECEx LCIE 15 0018X, II 3 GD, Ex nA IICT4 Gc, Ex tc IIIC T65Dc (-40C to -40C), Ex nA IIC T3 Gc, Ex tc IIIC T85Dc (-40C to -60C) IP66)
|
ABB
|
|
7TCA119130R0028
|
EM FLUO FIT- 5W.-PLATE-1X36W (Emergency fluorescent fixture, 5 wire loop - continuity plate 1x36W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nickel-plated brass M20 cable gland diam 6-12mm/8 5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0027
|
EM FLUO FIT- 5W.-PLATE 1X18W (Emergency fluorescent fixture, 5 wire loop - continuity plate 1x18W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nickel-plated brass M20 cable gland diam 6-12mm/8 5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0026
|
EM Fluo fit-5 wires2x58W (Emergency fluorescent fixture, 5 wire loop - 2x58W - electronic ballast 220- 240V 50-60Hz - 3hr battery - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - LCIE15 ATEX 1010X, IECEx LCIE 15 0018X, II 3 GD, Ex nA IICT4 Gc, Ex tc IIIC T65Dc (-40C to -40C), Ex nA IIC T3 Gc, Ex tc IIIC T85Dc (-40C to -60C) IP66)
|
ABB
|
|
7TCA119130R0025
|
EM FLUO FIT- 5W.-PLATE 2X18W (Emergency fluorescent fixture, 5 wire loop - continuity plate - 2x18W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nickel-plated brass M20 cable gland diam 6-12mm/8 5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0024
|
EM FLUO FIT- 5W.-PLATE 2X36W (Emergency fluorescent fixture, 5 wire loop - continuity plate - 2x36W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nickel-plated brass M20 cable gland diam 6-12mm/8 5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0022
|
EM FLUO FIT-5 WIRES1X18W (Emergency fluorescent fixture, 5 wire loop - 1x18W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119130R0002
|
EM Fluo fit-5 wires2x18W (Emergency fluorescent fixture, 5 wire loop - 2x18W - electronic ballast 220-240V 50-60Hz - 3hr battery - includes - one nylon M20 cable gland diam 6 - 12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0098
|
FLUO FIT-5 WIRES2X36W-M25 (Fluorescent Fixture, 5 Wire Loop - 2x36W - Electronic Ballast 110-260V 50-60Hz - Includes - One M25 Nylon Cable Gland Diam 8-17,5mm, Two M25 Nylon Stopping Plugs and Two Zinc-Plated Steel Brackets for Ceiling Mounting (V015) - Lamps Not Supplied - LCIE 15ATEX 1010X, IECEx LCIE 15.0018X, II 3 GD, Ex NA IICT4 Gc, Ex Tc IIIC T65Dc (-40C to +40C), Ex NA IICT5 Gc, Ex Tc IIIC T85Dc (-40C to +60C) IP66)
|
ABB
|
|
7TCA119120R0097
|
FLUO FIT-5 WIRES-2X18W-M25 (Fluorescent Fixture, 5 Wire Loop - 2x18W - Electronic Ballast 110-260V 50-60Hz - Includes - One M25 Nylon Cable Gland Diam 8-17,5mm, Two M25 Nylon Stopping Plugs and Two Zinc-Plated Steel Brackets for Ceiling Mounting (V015) - Lamps Not Supplied - LCIE 15ATEX 1010X, IECEx LCIE 15.0018X, II 3 GD, Ex NA IICT4 Gc, Ex Tc IIIC T65Dc (-40C to +40C), Ex NA IICT5 Gc, Ex Tc IIIC T85Dc (-40C to +60C) IP66)
|
ABB
|
|
7TCA119120R0096
|
FLUO FIT-5 W-THROUGH-2X18W (Fluorescent fixture, 5 wire through - 2x18W - electronic ballast 110-260V 50-60Hz - includes - two nylon M20 cable glands diam 6 - 12mm, one M20 nylon stopping plug and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0095
|
FLUO FIT-5W-THROUGH-PLATE-1X58W (Fluorescent fixture, 5 wire through - 2 continuity plates - 1x58W - electronic ballast 110-260V 50-60Hz - includes - two nickel-plated brass M20 cable glands diam int. 6-12mm/ext 8,5-16mm, one M20 nylon stopping plug and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0094
|
FLUO FIT-5 WIRES-PLATE-1X58W (Fluorescent fixture, 5 wire loop - continuity plate 1x58W - electronic ballast 110-260V 50-60Hz - includes - one nickel-plated brass M20 cable gland diam int. 6-12mm/ext 8,5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0093
|
FLUO FIT-5 W-THROUGH 1X58W (Fluorescent fixture, 5 wire through - 1x58W - electronic ballast 110-260V 50-60Hz - includes - two nylon M20 cable glands diam 6 - 12mm, one M20 nylon stopping plug and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0092
|
FLUO FIT-5W-THROUGH-PLATE-1X36W (Fluorescent fixture, 5 wire through - 2 continuity plates - 1x36W - electronic ballast 110-260V 50-60Hz - includes - two nickel-plated brass M20 cable glands diam int. 6-12mm/ext 8,5-16mm, one M20 nylon stopping plug and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0091
|
FLUO FIT-5 WIRES-PLATE-1X36W (Fluorescent fixture, 5 wire loop - continuity plate 1x36W - electronic ballast 110-260V 50-60Hz - includes - one nickel-plated brass M20 cable gland diam int. 6-12mm/ext 8,5-16mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0090
|
FLUO FIT-5 W-THROUGH 1X36W (Fluorescent fixture, 5 wire through - 1x36W - electronic ballast 110-260V 50-60Hz - includes - two nylon M20 cable glands diam 6 - 12mm, one M20 nylon stopping plug and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
|
7TCA119120R0089
|
Fluo fit-5 wires-plate-1x18W
|
ABB
|
|
7TCA119120R0088
|
FLUO FIT-5 W-THROUGH1X18W (Fluorescent fixture, 5 wire through - 1x18W - electronic ballast 110-260V 50-60Hz - includes - two nylon M20 cable glands diam 6 - 12mm, one M20 nylon stopping plug and two zinc-plated steel brackets for ceiling mounting (V015) - Lamps not supplied - Ex II 3 G, Ex nR IIC T4 Gc for -40C to 60C, Ex nR IIC T5 Gc for -40C to 35C, Ex II 3 D, Ex tc IIIC T100C to T135C Dc IP66, IEC 60529 (2001) IP66)
|
ABB
|
Òîâàðû
7861 - 7890 èç 8231
Íà÷àëî
|
Ïðåä.
|
261
262
263
264
265
|
Ñëåä. |
Êîíåö
|