7TAA1

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
7TAA122370R0009 3-WAY L-KIT,600A DB,35KV (600 Amp, 35kV, 600 Series Deadbreak 3-Way L-Kit. Does not include cable adapters or compression lugs, must be ordered separately.) ABB
7TAA122370R0006 L-KIT,2 WAY,600A DB,35KV (600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.) ABB
7TAA122370R0005 L-KIT,2 WAY,600A DB,35KV (600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Cold-Shrinkable Jacket Seal Included.) ABB
7TAA122370R0004 L-KIT,2 WAY,600A DB, 35KV (600 Amp, 35kV, 600 Series Deadbreak 2-Way L-Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.) ABB
7TAA122370R0003 2-WAY L-KIT,600A DB,35KV (600 Amp, 35kV, 600 Series Deadbreak 2-Way L-Kit. Does not include cable adapters or compression lugs, must be ordered separately.) ABB
7TAA122370R0002 L-KIT,2 WAY,600A DB,35KV (600 Amp, DeadBreak, 35KV, 2-Way L-Kit, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.) ABB
7TAA122370R0001 L-KIT,2 WAY,600A DB,35KV (600 Amp, DeadBreak, 35KV, 2-Way L-Kit, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Cold-Shrinkable Jacket Seal Included.) ABB
7TAA122360R0002 BUSHING EXTENDER W/N STUD (35kV 600 Series Deadbreak Bushing Extender (without Stud)) ABB
7TAA122360R0000 35KV600A DEADBRK BUSHING EXTEND (35kV 600 Series Deadbreak Bushing Extender (with Stud)) ABB
7TAA122350R0005 35KV DB ELBOW HOUSING (35kv Dead Break Elbow Housing) ABB
7TAA122350R0004 600 SERIES DIRECT TEST ELBOW (600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.) ABB
7TAA122350R0003 DIRECT TEST ELBOW, 35KV, 600A DB (Direct Test Elbow, 35kv, 600 Amp Dead Break) ABB
7TAA122350R0002 CABLE ACCESSORIES 600A 35KV (35kV 600 Series Deadbreak Direct Test Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.) ABB
7TAA122350R0001 DIRECT TEST ELBOW, 35KV, 600A DB (600 Amp, 35KV, Direct Test Elbow, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.) ABB
7TAA122350R0000 DIRECT TEST ELBOW, 35KV, 600A DB (Direct Test Elbow, 35kv, 600 Amp Dead Break) ABB
7TAA122340R0002 PARK BUSH, INSUL, 600A, 35KV W/STUD (35kV 600 Series Deadbreak Insulated Parking Bushing, with Stud.) ABB
7TAA122340R0001 35KV JUNCTION STAND OFF PLUGS (35kV 600 Series Deadbreak Insulated Parking Bushing, Factory assembled Stud, which is not field removable.) ABB
7TAA122340R0000 STAND-OFF PLUG-35KV (35kV 600 Series Deadbreak Insulated Parking Bushing) ABB
7TAA122320R0050 35KV,200A, TWO POINT JUNCTION W-CS (35kV 600 Series Deadbreak 2-Point Junction, No Bracket, with customer specific modifications) ABB
7TAA122320R0049 35KV 200A, FOUR POINT JUNCTION W-CS (35kV 600 Series Deadbreak 4-Point Junction, No Bracket, with customer specific modifications) ABB
7TAA122320R0048 35KV 200A THREE POINT JUNCTION W-CS (35kV 600 Series Deadbreak 3-point Junction, No Bracket, with customer specific modifications) ABB
7TAA122320R0043 BRACKET FOR JUNC,2PT,600A,35KV (Bracket For Junc, 2pt, 600 Amp, 35kv) ABB
7TAA122320R0008 JUNCT, 4PT, 600A DB, 35KV W/ADJ BKT (35kV 600 Series Deadbreak 4-Point Junction, with adjustable bracket.) ABB
7TAA122320R0007 600 AMP JUNCTION AL (35kV 600 Series Deadbreak 4-Point Junction, No Bracket) ABB
7TAA122320R0006 JUNCT, 3T, 600A DB, 35KV W/ADJ BKT (600 Amp Elbow Connector, 3-Way Junction, DeadBreak, 35KV, Rubber Junction with Stainless Steel Mounting Plate, Back Plate and adjustable Mounting Bracket) ABB
7TAA122320R0005 600 AMP JUNCTION AL (35kV 600 Series Deadbreak 3-point Junction, No Bracket) ABB
7TAA122320R0004 JUNCT, 2PT, 600A DB, 35KV W/BKT & U (600 Amp Elbow Connector, 2-Way Junction, DeadBreak, 35KV, Rubber Junction with Stainless Steel Mounting Plate, Back Plate and adjustable Mounting Bracket) ABB
7TAA122320R0003 35KV 600A DEADBRK 4PT JUNCTION (35kV 600 Series Deadbreak 4-Point Junction) ABB
7TAA122320R0002 35KV 600A DEADBRK 3PT JUNCTION (35kV 600 Series Deadbreak 3-point Junction) ABB
7TAA122320R0001 JUNCT, 2PT, 600A DB, 35KV NO BKT (35kV 600 Series Deadbreak 2-Point Junction, No Bracket) ABB

Òîâàðû 7621 - 7650 èç 15795
Íà÷àëî | Ïðåä. | 253 254 255 256 257 | Ñëåä. | Êîíåö | Âñå