7TAA1

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
7TAA137230R0028 EXPPRF COMBO FVNR 480V 100HP SIZE4 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 100 HP, 480 Volts, NEMA Size 4, Thermal Magnetic Circuit Breaker: 200 Amps, 480 Volts, Overall Dimensions: Width 12 Inches, Length 36 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0027 EXPPRF COMBO FVNR 480V 75HP SIZE4 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 75 HP, 480 Volts, NEMA Size 4, Thermal Magnetic Circuit Breaker: 175 Amps, 480 Volts, Overall Dimensions: Width 12 Inches, Length 36 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0026 EXPPRF COMBO FVNR 240V 40HP SIZE4 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 40 HP, 240 Volts, NEMA Size 4, Thermal Magnetic Circuit Breaker: 175 Amps, 240 Volts, Overall Dimensions: Width 12 Inches, Length 36 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0025 EXPPRF COMBO MCP 600V 50HP SIZE2 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing with Motor Circuit Protectors, Motor Starter: Maximum 50 HP, 600 Volts, NEMA Size 3, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0024 EXPPRF COMBO FVNR 600V 30HP SIZE3 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 30 HP, 600 Volts, NEMA Size 3, Thermal Magnetic Circuit Breaker: 70 Amps, 600 Volts, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0023 EXPPRF COMBO FVNR 600V 50HP SIZE3 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 50 HP, 600 Volts, NEMA Size 3, Thermal Magnetic Circuit Breaker: 100 Amps, 600 Volts, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0022 EXPPRF COMBO FVNR 480V 30HP SIZE3 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 30 HP, 480 Volts, NEMA Size 3, Thermal Magnetic Circuit Breaker: 70 Amps, 480 Volts, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0021 EXPPRF COMBO FVNR 480V 50HP SIZE3 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 50 HP, 480 Volts, NEMA Size 3, Thermal Magnetic Circuit Breaker: 100 Amps, 480 Volts, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0020 EXPPRF COMBO FVNR 240V 30HP SIZE3 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 30 HP, 240 Volts, NEMA Size 3, Thermal Magnetic Circuit Breaker: 125 Amps, 240 Volts, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0019 EXPPRF COMBO FVNR 240V 20HP SIZE3 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 20 HP, 240 Volts, NEMA Size 3, Thermal Magnetic Circuit Breaker: 100 Amps, 240 Volts, Overall Dimensions: Width 12 Inches, Length 24 Inches, Depth 8 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0018 EXPPRF COMBO MCP 600V 25HP SIZE2 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing with Motor Circuit Protectors, Motor Starter: Maximum 25 HP, 600 Volts, NEMA Size 2, Overall Dimensions: Width 7 Inches, Length 27 Inches, Depth 6 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0017 EXPPRF COMBO FVNR 600V 25HP SIZE2 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 25 HP, 600 Volts, NEMA Size 2, Thermal Magnetic Circuit Breaker: 70 Amps, 600 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0016 EXPPRF COMBO FVNR 480V 25HP SIZE2 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 25 HP, 480 Volts, NEMA Size 2, Thermal Magnetic Circuit Breaker: 70 Amps, 480 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0015 EXPPRF COMBO FVNR 240V 10HP SIZE2 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 10 HP, 240 Volts, NEMA Size 2, Thermal Magnetic Circuit Breaker: 70 Amps, 240 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0014 EXPPRF COMBO FVNR 240V 15HP SIZE2 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 15 HP, 240 Volts, NEMA Size 2, Thermal Magnetic Circuit Breaker: 100 Amps, 240 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0013 EXPPRF COMBO MCP 480/600V 10HP SIZ0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing with Motor Circuit Protectors, Motor Starter: Maximum 10 HP, 480/600 Volts, NEMA Size 1, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0012 EXPPRF COMBO MCP 480/600V 5HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing with Motor Circuit Protectors, Motor Starter: Maximum 5 HP, 480/600 Volts, NEMA Size 0, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0011 EXPPRF COMBO MCP 480/600V 2HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing with Motor Circuit Protectors, Motor Starter: Maximum 2 HP, 480/600 Volts, NEMA Size 0, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0010 EXPPRF COMBO MCP 480/600V 1HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing with Motor Circuit Protectors, Motor Starter: Maximum 1 HP, 480/600 Volts, NEMA Size 0, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0009 EXPPRF COMBO FVNR 600V 10HP SIZE1 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 10 HP, 600 Volts, NEMA Size 1, Thermal Magnetic Circuit Breaker: 30 Amps, 600 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0008 EXPPRF COMBO FVNR 600V 5HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 5 HP, 600 Volts, NEMA Size 0, Thermal Magnetic Circuit Breaker: 20 Amps, 600 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0007 EXPPRF COMBO FVNR 600V 20HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 2 HP, 600 Volts, NEMA Size 0, Thermal Magnetic Circuit Breaker: 15 Amps, 600 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0006 EXPPRF COMBO FVNR 480V 10HP SIZE1 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 10 HP, 480 Volts, NEMA Size 1, Thermal Magnetic Circuit Breaker: 30 Amps, 480 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0005 EXPPRF COMBO FVNR 480V 5HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 5 HP, 480 Volts, NEMA Size 0, Thermal Magnetic Circuit Breaker: 20 Amps, 480 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0004 EXPPRF COMBO FVNR 480V 2HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 2 HP, 480 Volts, NEMA Size 0, Thermal Magnetic Circuit Breaker: 15 Amps, 480 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0003 EXPPRF COMBO FVNR 240V 7.5HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 7-1/2 HP, 240 Volts, NEMA Size 1, Thermal Magnetic Circuit Breaker: 50 Amps, 240 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0002 EXPPRF COMBO FVNR 240V 5HP SIZE1 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 5 HP, 240 Volts, NEMA Size 1, Thermal Magnetic Circuit Breaker: 30 Amps, 240 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0001 EXPPRF COMBO FVNR 240V 3HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 3 HP, 240 Volts, NEMA Size 0, Thermal Magnetic Circuit Breaker: 20 Amps, 240 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137230R0000 EXPPRF COMBO FVNR 240V 2HP SIZE0 (Explosionproof Combination Motor Starter Enclosure, Full Voltage Non-Reversing, Motor Starter: Maximum 2 HP, 240 Volts, NEMA Size 0, Thermal Magnetic Circuit Breaker: 15 Amps, 240 Volts, Overall Dimensions: Width 6 Inches, Length 23 Inches, Depth 5 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB
7TAA137200R0004 EXPPRF COMBO STARTER ENCLOSURE 5 (Explosionproof Combination Starter, Enclosure Only, Full Voltage Non-Reversing, Includes Handle and Reset Button, Overall Dimensions: Width 16 Inches, Length 46 Inches, Depth 10 Inches, UL, CSA, cULus, NEMA 4, 7BCD, 9EFG, Approved for Class I, II, and III Hazardous Locations, Copper-Free Aluminum) ABB

Òîâàðû 3721 - 3750 èç 15795
Íà÷àëî | Ïðåä. | 123 124 125 126 127 | Ñëåä. | Êîíåö Âñå