7TAA1
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA123830R0183
|
TRANS CBL JT SHLD ST4 SZ3 42P HS4J (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Copper, Connector Size Code 42P, Heatsink Size 4, Heatsink Bore Code J- Bore Diameter 1.250 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0182
|
TRANS CBL JT SHLD ST4 SZ3 38P HS3F (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Copper, Connector Size Code 38P, Heatsink Size 3, Heatsink Bore Code F- Bore Diameter 1.015 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0181
|
TRANS CBL JT SHLD ST4SZ3 36P HS3F (_138 Kv, Transmission Cable Joint, Splice)
|
ABB
|
|
7TAA123830R0180
|
TRANS CBL JT SHLD ST4 SZ3 33P HS4 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Copper,, Connector Size Code 33P, Heatsink Size 4, Heatsink Bore Code D- Bore Diameter 0.843 inches, Type Shield - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0179
|
TRANS CBL JT SHLD ST4 SZ3 31P HS4 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Copper, Connector Size Code 31P, Heatsink Size 4, Heatsink Bore Code C - Bore Diameter 0.750 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 6 with Split Bolts quantity 12, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0178
|
TRANS CBL JT SHLD ST4 SZ3 31P HS4C (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Copper, Connector Size Code 31P, Heatsink Size 4, Heatsink Bore Code C - Bore Diameter 0.750 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0177
|
TRANS CBL JT SHLD ST4 SZ3 39P HS3 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Copper, Connector Size Code 39P, Heatsink Size 3, Heatsink Bore Code G - Bore Diameter 1.125 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0176
|
TRANS CBL JT SHLD ST4 SZ3 36P HS5F (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 3, Connector Type Aluminum, Connector Size Code 36P, Heatsink Size 5, Heatsink Bore Code F - Bore Diameter 1.015 inches, Type Shield - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot quantity 2 with Split Bolts quantity 4, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0175
|
TRANS CBL JT SHLD ST4 SZ7 59P HS0 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 7, Connector Type Copper/No Connector required, Connector Size Code 59P, Heatsink Size 0 not included, Heatsink Bore Code 0 - not included, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0174
|
TRANS CBL JT SHLD ST4 SZ4 36P HS0 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 4, Connector Type Copper/No Connector required, Connector Size Code 36P, Heatsink Size 0 not included, Heatsink Bore Code 0 - not included, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0173
|
138TCJS44246P5LBFNA-CSMEA (138 kV, TCJ - Transmission Cable Joint, Housing Type S - Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch))
|
ABB
|
|
7TAA123830R0172
|
TRANS CBL JT SHLD ST4 SZ6 57P HS65 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 57P, Heatsink Size 65, Heatsink Bore Code V - 6 Stainless Cable Ties, Split Bolts quantity 4, Type Shield - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 6 with Split Bolts quantity 12, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0171
|
TRANS CBL JT SHLD ST4 SZ6 46P HS5L (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 4, Connector Type Copper, Connector Size Code 46P, Heatsink Size 5, Heatsink Bore Code L - 1.406 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 4 with Split Bolts quantity 8, Armour Kit - not required, Outer Jacket Restoration Kit - Jacket Tape 10 Rolls, Customer Special Modifications)
|
ABB
|
|
7TAA123830R0170
|
138TCJS44242P5JENNB-CS1088 SPLICE (138 kV, TCJ - Transmission Cable Joint, Housing Type S - Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch), with Customer Specific Modifications - The heat shrink tubing must have separators to prevent the heat gluing them together due to high heat environment.)
|
ABB
|
|
7TAA123830R0169
|
138TCJS45246P55LBNNB-CS1088 SPLICE (138 kV, TCJ - Transmission Cable Joint, Housing Type S - Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch), with Customer Specific Modifications - The heat shrink tubing must have separators to prevent the heat gluing them together due to high heat environment.)
|
ABB
|
|
7TAA123830R0168
|
138TCJS45B53P6RBNNB,SPLICE138KV (138 kV, TCJ - Transmission Cable Joint, Housing Type S - Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch))
|
ABB
|
|
7TAA123830R0167
|
TRANS CBL JT SHLD ST4 SZ6 54P HS65 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 54P, Heatsink Size 65, Heatsink Bore Code S - 1.750 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0166
|
TRANSMISSION CABLE JOINT (138 KV, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4)
|
ABB
|
|
7TAA123830R0164
|
TRANSMISSION SPLICE 138KV (138 KV, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4)
|
ABB
|
|
7TAA123830R0163
|
TRANSMISSION SPLICE 138KV (138 KV, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4)
|
ABB
|
|
7TAA123830R0161
|
TRANS CBLE JT SHLD SHIELDBRK ST4 (138 KV, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4)
|
ABB
|
|
7TAA123830R0115
|
TRANS CBL JT SHLD ST4 SZ6 46P HS0 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 5, Connector Type Copper/No Connector required, Connector Size Code 46P, Heatsink Size 0 not included, Heatsink Bore Code 0 - not included, Type Shield - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0114
|
TRANS CBL JT SHLD ST4 SZ6 53P HS0 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 53P, Heatsink Size 0 not included, Heatsink Bore Code 0 - not included, Type Shield - Lead, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0113
|
TRANS CBL JT SHLD ST4 SZ6 55P HS0 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 55P, Heatsink Size 0 not included, Heatsink Bore Code 0 - not included, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0112
|
TRANS CBL JT SHLD ST4 SZ6 54P HS0 (138 Kv, Transmission Cable Joint, Housing Type - ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 54P, Heatsink Size 0 not included, Heatsink Bore Code 0 - not included, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0107
|
TRANS CBL JT NSHLD ST4 SZX 36P HSX (138 Kv, Transmission Cable Joint, Housing Type - Non-ShieldBreak, Housing Style 4, Housing Size X - not included within kit, Connector Type Aluminum/No Connector required, Connector Size Code 36P, Heatsink Size X - not included within kit, Heatsink Bore Code X - not included within kit, Type Shield - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 1 with Split Bolts quantity 4, Armour Kit - not required, Outer Jacket Restoration Kit - not included within kit)
|
ABB
|
|
7TAA123830R0106
|
TRANSMISSION SPICE, 138KV (138 Kv, Transmission Cable Joint, Housing Type - Non-ShieldBreak, Housing Style 4, Housing Size X - not included within kit, Connector Type Aluminum/No Connector required, Connector Size Code 36P, Heatsink Size N - N/R, Heatsink Bore Code 0 - not included, Type Shield - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 1 with Split Bolts quantity 4, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
|
7TAA123830R0105
|
138 TRANSMISSION CABLE JOINT (138 Kv, Transmission Cable Joint, Housing Type - Non-ShieldBreak, Housing Style 4, Housing Size 7, Connector Type Copper/No Connector required, Connector Size Code 00P -not included, Heatsink Size 0 - not included, Heatsink Bore Code 0 - not included, Type Shield - Unknown, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0104
|
TRANS CBL JT NSHLD ST4 SZ6 00P (138 Kv, Transmission Cable Joint, Housing Type - Non-ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 00P -not included, Heatsink Size 0 - not included, Heatsink Bore Code 0 - not included, Type Shield - Unknown, Metallic Screen Continuity Kit - not required, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package, Customer Special Modifications - IEC Labels/Tapes)
|
ABB
|
|
7TAA123830R0103
|
TRANS CBL JT NSHLD ST4 SZ6 54P HS6 (138 Kv, Transmission Cable Joint, Housing Type - Non-ShieldBreak, Housing Style 4, Housing Size 6, Connector Type Copper/No Connector required, Connector Size Code 54P, Heatsink Size 6, Heatsink Bore Code S - 1.750 inches, Type Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable 6 foot quantity 3 with Split Bolts quantity 12, Armour Kit - not required, Outer Jacket Restoration Kit - Heat Shrink Standard Package)
|
ABB
|
Òîâàðû
3391 - 3420 èç 15795
Íà÷àëî
|
Ïðåä.
|
112
113
114
115
116
|
Ñëåä. |
Êîíåö
|