7TCA2

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
7TCA297090R0082 STAINLESSS STEEL 1/2NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 20mm, 1/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Stainless Steel with Epoxy Resin Barrier) ABB
7TCA297090R0081 1/2NPT SS FLAMEPROOF FOR 20MM CONDU (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 20mm, 1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Stainless Steel with Epoxy Resin Barrier) ABB
7TCA297090R0080 STAINLESS STEEL 1/2NPT TO 3/8NPT (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 20mm, 3/8 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Stainless Steel with Epoxy Resin Barrier) ABB
7TCA297090R0079 1/2NPT SS FLAMEPROOF FOR 16MM CONDU (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 16mm, 1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Stainless Steel with Epoxy Resin Barrier) ABB
7TCA297090R0078 NICKLE PLATED BRASS 2 NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 63mm, 2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0077 2 NPT NICKEL FLAMEP ROOF GLAND (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 63mm, 2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0076 NICKLE PLATED BRASS1.1/2NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 50mm, 1-1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0075 1.1/2 NPT NICKEL FLAMEP ROOF GLAND (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 50mm, 1-1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0074 NICKLE PLATED BRASS1.1/4NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 40mm, 1-1/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0073 1.1/4 NPT NICKEL FLAMEP ROOF GLAND (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 40mm, 1-1/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0072 NICKLE PLATED BRASS 1 NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 32mm, 1 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0071 1 NPT NICKEL FLAMEPROOF (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 32mm, 1 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0070 PLATED 90 DEGREE 1 INCH NPT (Liquid Tight Fitting for Conduit, ATEX Flameproof 90 Degree Elbow Gland, External Male Thread, Conduit Size 32mm, 1 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0069 NICKLE PLATED BRASS 3/4NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 25mm, 3/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0068 3/4NPT NICKEL FLAMEPROOF (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 25mm, 3/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0067 PLATED 90 DEGREE 3/4NPT (Liquid Tight Fitting for Conduit, ATEX Flameproof 90 Degree Elbow Gland, External Male Thread, Conduit Size 25mm, 3/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0066 NICKLE PLATED BRASS 1/2NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 20mm, 1/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0065 1/2NPT NICKEL FLAMEPROOF FOR 20MM C (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 20mm, 1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0064 90DEG 1/2 GLAND 20MM CONDUIT (Liquid Tight Fitting for Conduit, ATEX Flameproof 90 Degree Elbow Gland, External Male Thread, Conduit Size 20mm, 1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0063 UNIVERSAL 1/2NPT NP M16 FEMALE THRE (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 20mm, 3/8 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0062 1/2NPT NICKEL FLAMEPROOF FOR 16MM C (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 16mm, 1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Nickel Plated Brass with Epoxy Resin Barrier) ABB
7TCA297090R0061 BRASS 2NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 63mm, 2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0060 2 NPT FLAMEPROOF GLAND (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 63mm, 2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0059 BRASS 1.1/2NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 50mm, 1-1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0058 1.1/ 2NPT FLAMEPROOF (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 50mm, 1-1/2 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0057 BRASS 1.1/4NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 40mm, 1-1/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0056 1.1/ 4NPT FLAMEPROOF (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 40mm, 1-1/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0055 BRASS 1NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 32mm, 1 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0054 1 NPT FLAMEPROOF GLAND FOR M32 COND (Liquid Tight Fitting for Conduit, ATEX Flameproof G1 Gland, Straight with External Male Thread, Conduit Size 32mm, 1 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div2 ABCD, Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB
7TCA297090R0053 BRASS 3/4NPT FITTING (Liquid Tight Fitting for Conduit, Universal Gland, Straight with External Male Thread, Conduit Size 25mm, 3/4 Inch NPT Thread, CSA, Group I & II, Zones 1, 2, 21 and 22, Class I Div1 BCD (Rigid Conduit Only), Class II Div1 EFG, Brass with Epoxy Resin Barrier) ABB

Òîâàðû 2101 - 2130 èç 10158
Íà÷àëî | Ïðåä. | 69 70 71 72 73 | Ñëåä. | Êîíåö Âñå