7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA266430R0052
|
BUS SUPPORT 6 IPS 10 3/8 BC (Aluminum EHV Welded Substation Bus Support - Pipe to Bolt Circle - Double Ring - Rigid or Slip Fit - 500kV Maximum - 6 inch NPS Pipe to 10-3/8 inch Bolt Circle)
|
ABB
|
|
7TAA266430R0051
|
WELDED VERTICAL BUS SUPPORT (Aluminum EHV Welded Substation Bus Support - Pipe to Bolt Circle - Vertical Take-off - 500kV Maximum - 6 inch NPS Pipe to 5 inch Bolt Circle)
|
ABB
|
|
7TAA266430R0050
|
BLTD EXPANSION TERM PIPE TO FLAT (Aluminum EHV Bolted Substation Terminal - Pipe to Pad - Expansion Style - Center-formed Pad Perpendicular to Shunt Plane - 345kV Maximum (using Hardware Shields, sold separately) - 4 inch NPS Pipe to 4 inch NPS Pipe, 90 Degree Bend, EH - Schedule 80 Pipe)
|
ABB
|
|
7TAA266430R0049
|
ALUMINUM TERMINAL W/90 DEG. PAD (Aluminum EHV Bolted Substation Terminal - Pipe to Pad - 90 Degree - 500kV Maximum (using Hardware Shields, sold separately) - 6 inch NPS Pipe to 4X4 inch, 4-hole Pad)
|
ABB
|
|
7TAA266430R0048
|
EHV BOLTED ELBOW 90 DEGREE,5 SPSAL (Aluminum EHV Bolted Substation Coupler - Pipe to Pipe - 90 Degree - 500kV Maximum - 5 inch NPS Pipe to 5 inch NPS Pipe)
|
ABB
|
|
7TAA266430R0047
|
90 DEG BOLTED ELBOW FOR 4 IN PIPE (Aluminum EHV Bolted Substation Coupler - Pipe to Pipe - 90 Degree - 500kV Maximum - 4 inch NPS Pipe to 4 inch NPS Pipe)
|
ABB
|
|
7TAA266430R0046
|
BOLTED TERMINAL TWO CABLES TO FLAT (Aluminum EHV Bolted Substation Terminal - 2 Cables to Pad - Straight - Center-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1000-1272 AAC 795 (30/19), 874.5, 900 (54/7), 954-1113 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0045
|
BOLTED TERMINAL 2 CABLES TO FLAT (Aluminum EHV Bolted Substation Terminal - 2 Cables to Pad - 90 Degree - Center-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1000-1272 AAC 795 (30/19), 874.5, 900 (54/7), 954-1113 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0044
|
BOLTED TERMINAL TWO CABLES TO FLAT (Aluminum EHV Bolted Substation Terminal - 2 Cables to Pad - 45 Degree - Center-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1000-1272 AAC 795 (30/19), 874.5, 900 (54/7), 954-1113 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0043
|
EHV BOLTED TERMINAL (Aluminum EHV Bolted Substation Terminal - 2 Cables to Pad - Straight - Center-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1000-1272 AAC 795 (30/19), 874.5, 900 (54/7), 954-1113 ACSR to 4X4 inch, 4-hole Pad)
|
ABB
|
|
7TAA266430R0042
|
EHV CONN BOLTED CABLE TO CABLE (Aluminum EHV Bolted Substation Tee Connector - Cable to Cable - Straight - 500kV Maximum - 3007.5-3500 AAC to 1590-1600 AAC 1351.5 (54/19), 1431, 1510.5 (45/7) ACSR)
|
ABB
|
|
7TAA266430R0041
|
EHV BOLTED TERMINAL (Aluminum EHV Bolted Substation Terminal - Cable to Pad - Straight - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1700-2000 AAC 1510.5 (54/19), 1590-1780 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0040
|
EHV BOLTED TERMINALS (Aluminum EHV Bolted Substation Terminal - Cable to Pad - 90 Degree - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1700-2000 AAC 1510.5 (54/19), 1590-1780 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0039
|
EH-1292-B-45-SSB, BOLTED TERM. CABL (Aluminum EHV Bolted Substation Terminal - Cable to Pad - 45 Degree UP Bend - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1700-2000 AAC 1510.5 (54/19), 1590-1780 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0038
|
BOLTED TERMINAL CABLE TO FLAT (Aluminum EHV Bolted Substation Terminal - Cable to Pad - Straight - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1000-1272 AAC 795 (30/19), 874.5, 900 (54/7), 954-1113 ACSR to 4X4 inch, 4-hole Pad, SSB - Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0037
|
230KV BOLTED CONN (230 kV, Cornoa Free Terminal Connector, Bolted, Tinned for 795 to 4 Hole Nema Pad)
|
ABB
|
|
7TAA266430R0036
|
SUBSTATION CONNECTOR (Aluminum EHV Bolted Substation Terminal - Cable to Pad - 90 Degree Bend - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 874.5-954 AAC 715.5 (30/19), 795 (45/7,54/7,24/7,26/7), 900 (45/7) ACSR to 4X4 inch, 4-hole Pad)
|
ABB
|
|
7TAA266430R0020
|
EH-5294
|
ABB
|
|
7TAA266430R0019
|
AL EHV Term 90Deg 3-1/2 Pipes (Aluminum EHV Bolted Substation Terminal - Pipe to Pad - Expansion Style - Center-formed Pad Perpendicular to Shunt Plane - 345kV Maximum (using Hardware Shields, sold separately) - 3 1/2 inch NPS Pipe to 3 1/2 inch NPS Pipe, 90 Degree Bend)
|
ABB
|
|
7TAA266430R0018
|
AL BOLTED EXPS TERM TYPE AFF-CT-CF (Aluminum Bolted Expansion Terminal, Pipe to Flat (345kV Nominal System Voltage) - Type AFF-CT-CF SPS 3-1/2, Number of Conductors 4, 4 x 4 inch 4 Hole NEMA Flat)
|
ABB
|
|
7TAA266430R0017
|
AL BOLTED TERMINAL 90 DEG AVP-90-CF (Aluminum 90 Degree Bolted Terminal, Pipe to Flat - Type AVP-90-CF, SPS 3-1/2, 4 x 4 inch 4 Hole NEMA Flat)
|
ABB
|
|
7TAA266430R0016
|
AL EHV Term 90Deg 954 AAC - 4NN (Aluminum EHV Bolted Substation Terminal - 2 Cables to Pad - 90 Degree - Center-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 874.5-954 AAC 715.5 (30/19), 795 (45/7,54/7,24/7,26/7), 900 (45/7) ACSR to 4X4 inch, 4-hole Pad)
|
ABB
|
|
7TAA266430R0015
|
ALUM BOLTED TERMINAL AGL-2-CF 4HOLE (Aluminum Bolted Terminal, Two Cables to Flat - Type AGL-2-CF, Cable 874-954 AAC 795-900 ACSR, 4 X 4 inch 4 Hole NEMA Flat)
|
ABB
|
|
7TAA266430R0014
|
ALUM BOLTED TERMINAL AGL-CF (Aluminum Bolted Terminal, Cable to Flat - Type AGL-CF, Cable 3000 AAC, 4 X 4 inch 4 Hole Nema Flat, with Stainless Steel Bolt, Lock Washer and Silicon Bronze Nut)
|
ABB
|
|
7TAA266430R0013
|
ALUM BOLTED TERMINAL AGL-CF (Aluminum Bolted Terminal, Cable to Flat - Type AGL-CF, Cable 2500 AAC, 4 X 4 inch 4 Hole Nema Flat)
|
ABB
|
|
7TAA266430R0012
|
ALUM BOLTED TERMINAL AGL-CF (Aluminum Bolted Terminal, Cable to Flat - Type AGL-CF, Cable 2300 AAC 2167 ACSR, 4 X 4 inch 4 Hole Nema Flat)
|
ABB
|
|
7TAA266430R0011
|
ALUM BOLTED TERMINAL AGL-CF (Aluminum Bolted Terminal, Cable to Flat - Type AGL-CF, Cable 2000 AAC 1590-1780 ACSR, 4 X 4 inch 4 Hole Nema Flat)
|
ABB
|
|
7TAA266430R0010
|
AL EHV Term 90Deg 1510.5AAC 4NN (Aluminum EHV Bolted Substation Terminal - Cable to Pad - 90 Degree - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1300-1510.5 AAC 1192.5-1272, 1351.5 (45/7), 1361 ACSR to 4X4 inch, 4-hole Pad)
|
ABB
|
|
7TAA266430R0009
|
ALUM BOLTED TERMINAL AGL-CF (Aluminum Bolted Terminal, Cable to Flat - Type AGL-CF, Cable 1351-1510 AAC 1272 ACSR, 4 X 4 inch 4 Hole Nema Flat)
|
ABB
|
|
7TAA266430R0008
|
AL EHV Term 90Deg 1272AAC-4NN (Aluminum EHV Bolted Substation Terminal - Cable to Pad - 90 Degree - Side-formed Pad - 500kV Maximum (using Hardware Shields, sold separately) - 1000-1272 AAC 795 (30/19), 874.5, 900 (54/7), 954-1113 ACSR to 4X4 inch, 4-hole Pad)
|
ABB
|
Òîâàðû
15181 - 15210 èç 23691
Íà÷àëî
|
Ïðåä.
|
505
506
507
508
509
|
Ñëåä. |
Êîíåö
|