7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA266250R0163
|
CABLE SPACER (Bolted Aluminum Connector, Type ACS2, Cable Spacer, Two Cables, Cable Size 250 - ACC 2000-2500, ACSR 2156-2167, Cable Diameter 1.630-1.824, Length 8 inches. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. EH is for Galvanized Hardware.)
|
ABB
|
|
7TAA266250R0162
|
BUS SUPPORT,CABLE (Aluminum Bolted Substation Cable Spacer (2 Cables) - Cable to Cable - 1100-2500AAC 1113-2300ACSR to)
|
ABB
|
|
7TAA266250R0161
|
BOLTED AL CABLE SPACE (Bolted Aluminum Connector, Type ACS2, Cable Spacer, Two Cables, Cable Size 200 - ACC 1500-2000, ACSR 1272-1780, Cable Diameter 1.382-1.632, Length 8 inches. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. EH is for Galvanized Hardware.)
|
ABB
|
|
7TAA266250R0160
|
CABLE SPACER W/HDG HDW (Bolted Aluminum Connector, Type ACS2, Cable Spacer, Two Cables, Cable Size 200 - ACC 1500-2000, ACSR 1272-1780, Cable Diameter 1.382-1.632, Length 4 inches. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. EH is for Galvanized Hardware.)
|
ABB
|
|
7TAA266250R0159
|
CABLE SPACER W/HDG HDW (Bolted Aluminum Connector, Type ACS2, Cable Spacer, Two Cables, Cable Size 160 - ACC 1250-1600, ACSR 1113-1431, Cable Diameter 1.288-1.427, Length 4 inches. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. EH is for Galvanized Hardware.)
|
ABB
|
|
7TAA266250R0158
|
BOLTED AL. CABLE SPACER (Aluminum Bolted Substation Cable Spacer with Pad - Cable to Cable - 1250-1600 AAC 1113-1431 ACSR to 4 X 4 Inch 4 hole Pad)
|
ABB
|
|
7TAA266250R0157
|
CABLE SPACER 2-1590 AAC 16 SPACING (Bolted Aluminum Connector, Type ACS2, Cable Spacer, Two Cables, Cable Size 160 - ACC 1250-1600, ACSR 1113-1431, Cable Diameter 1.288-1.427, Length 16 inches. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1.)
|
ABB
|
|
7TAA266250R0156
|
AL Cable Spacer 2X 1250 AAC -4N (Bolted Aluminum, Cable Spacer, 2 Cables. Cable Size AAC 900-1250, ACSR 715.5-1113. Cable Diameter 1.081 inch to 1.293 inch. Length 8 inches. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. 3 Inch 4-Hole NEMA Flat.)
|
ABB
|
|
7TAA266250R0154
|
FLAT ALUM BAR 7.5 LONG W 4 HOLE (Flat Aluminum Bar 3 inches wide by 7.5 long with 4-Hole NEMA pad on each end.)
|
ABB
|
|
7TAA266250R0152
|
BUS BAR EXTENSION (Bus Bar Extension, Copper Bar with 6 inch 6-Hole Pad on one End and 4 inch 4 Hole Pad on other End. Rated to 4000 Amps.)
|
ABB
|
|
7TAA266250R0151
|
BOLTED ALUM.MULTI PAD BUS EHV (Bolted Aluminum Multi Pad Bus, Extra High Voltage, 4 X 6 inch Wide Pad, 4 X 4 inch pad)
|
ABB
|
|
7TAA266250R0150
|
ABY.5-4NN-4NN-16.75 HOMAC SUBSTATIO
|
ABB
|
|
7TAA266250R0117
|
BA-1159
|
ABB
|
|
7TAA266250R0116
|
AWGS2-4N G
|
ABB
|
|
7TAA266250R0115
|
AL 3/4 in Ground Stud-4NN Pad 45Deg (Aluminum Welded Substation Ground Stud - Ground Stud to Nema Pad - 3/4 inch Diameter Stud - 230kV Maximum - 4X4 inch, 4-hole Pad, 90 Degree Bend)
|
ABB
|
|
7TAA266250R0114
|
AL 3/4 in Ground Stud-4N Pad 45Deg (Aluminum Welded Substation Ground Stud - Ground Stud to Nema Pad - 3/4 inch Diameter Stud - 230kV Maximum - 3X3 inch, 4-hole Pad, 45 Degree Bend)
|
ABB
|
|
7TAA266250R0113
|
AL WELDED SUBSTA GRND STUD 3/4IN (Aluminum Welded Substation Ground Stud (3/4 inch Diameter Stud) - Ground Stud to Nema Pad - 3 X 3 inch 4 hole Pad)
|
ABB
|
|
7TAA266250R0112
|
Hot Clamp GND Stud 11N (Grounding Stud for Extension Studs for Hot Clamps, for use with Schedule 40 and 80 tube. 11N - is a 2 Hold Pad, but Holes are side to side instead of inline. (Basically two 1-hole pads side-to-side but the same pad.))
|
ABB
|
|
7TAA266250R0111
|
AL BOLTED FLEX STRAP CONNCTR STRT (Aluminum Bolted Flexible Strap Connector (Straight) - 4 inch 4-Hole NEMA Pad, Thickness 1/4 inch)
|
ABB
|
|
7TAA266250R0109
|
AL BOLTED SUBSTA PARALLEL GRV CLMP (Aluminum Bolted Substation Parallel Groove Clamp (Non U-bolt Style) - Cable to Cable - 1113-2500 AAC 1431-2300 ACSR to 1113-2500 AAC 1431-2300 ACSR)
|
ABB
|
|
7TAA266250R0108
|
APP3-143-80 (Aluminum Parallel Clamp, Cable to Cable, Main 874-1272, Tap 556-800, 1/2 inch Bolt, Length 4-7/8 inches.)
|
ABB
|
|
7TAA266250R0107
|
APP3-143-50 (GB-3671) (Aluminum Parallel Clamp, Cable to Cable, Main 874-1272, Tap 350-500, 1/2 inch Bolt, Length 4-7/8 inches.)
|
ABB
|
|
7TAA266250R0106
|
APP3-143-4/0 (Aluminum Parallel Clamp, Cable to Cable, Main 874-1272, Tap 3/0-4/0, 1/2 inch Bolt, Length 4-7/8 inches.)
|
ABB
|
|
7TAA266250R0105
|
APP3-143-2/0 (GB-3668) (Aluminum Parallel Clamp, Cable to Cable, Main 874-1272, Tap 1/0-2/0, 1/2 inch Bolt, Length 3-1/2 inches.)
|
ABB
|
|
7TAA266250R0104
|
AL BOLTED SUBSTA PARALLEL GRV CLMP (Aluminum Bolted Substation Parallel Groove Clamp (Non U-bolt Style) - Cable to Cable - 1000-1431 AAC 874-1272 ACSR to 1000-1431 AAC 874-1272 ACSR)
|
ABB
|
|
7TAA266250R0103
|
AL BOLTED SUBSTATION END CAP BELL (Aluminum Bolted Substation End Cap/Corona Bell (Drive Fit) - Pipe - 6 inch Pipe to)
|
ABB
|
|
7TAA266250R0102
|
AL BOLTED SUBSTATION END CAP BELL (Aluminum Bolted Substation End Cap/Corona Bell (Drive Fit) - Pipe - 5 inch Pipe to)
|
ABB
|
|
7TAA266250R0101
|
AL BOLTED SUBSTATION END CAP BELL (Aluminum Bolted Substation End Cap/Corona Bell (Drive Fit) - Pipe - 4 inch Pipe to)
|
ABB
|
|
7TAA266250R0100
|
AL BOLTED SUBSTATION END CAP BELL (Aluminum Bolted Substation End Cap/Corona Bell (Drive Fit) - Pipe - 3-1/2 inch Pipe)
|
ABB
|
|
7TAA266250R0099
|
AL BOLTED SUBSTATION END CAP BELL (Aluminum Bolted Substation End Cap/Corona Bell (Drive Fit) - Pipe - 3 inch Pipe to)
|
ABB
|