7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA261280R0051
|
Mech Conn 4 Towers 750 mcm Rockets (Mechanical Connector Compounded, 4 Towers (750 MCM) With Rockets)
|
ABB
|
|
7TAA261280R0050
|
Mech Conn 4 Tower 750mcm Rocket 4IN (Mechanical Connector Compounded, 4 Towers (750 MCM) With 4 Inch Wide Pad With 4 Holes, Rockets)
|
ABB
|
|
7TAA261280R0049
|
Mech Conn 3 Towers 750 mcm Rockets (Mechanical Connector Compounded 3 Towers (750 MCM) With Rockets)
|
ABB
|
|
7TAA261280R0048
|
Mech Conn 2 Towers 750 mcm Rockets (Mechanical Connector Compounded 2 Towers (750 MCM) With Rockets)
|
ABB
|
|
7TAA261280R0047
|
FS AL TFR Conn #6-350 6 Cond Right (Flood Seal, Aluminum Transformer Connector, #6 - 350 kcmil, Stud 5/8 inch, Six Connector, Option R - Right Hand Feed)
|
ABB
|
|
7TAA260520R0004
|
Copper Disconnect Link
|
ABB
|
|
7TAA260520R0002
|
Aluminum Mechanical Fuse Clip
|
ABB
|
|
7TAA260520R0001
|
3737-20 SUB FINISHED CAP (Submersible Rocket, EPDM Rubber, Double In-Line Unit, Overall Diameter .968 inch, Overall Length 2.859 inch, 3 outlets, Outside Diameter .437, .343 and .250 inch. Length .641, .375 and .187 inch.)
|
ABB
|
|
7TAA260520R0000
|
3737-19 SUB FINISHED ROCKET (Submersible Rocket, EPDM Rubber, Double In-Line Unit, Overall Diameter 1.062 inch, Overall Length 3.700 inch, 3 outlets, Outside Diameter .437, .343 and .250 inch. Length .641, .375 and .187 inch.)
|
ABB
|
|
7TAA260100R0032
|
ALUM MECHANICAL SPLICE 2 WIRE (Aluminum Mechanical Splice, Double Screws, 18 Inches Long, 2 Wire)
|
ABB
|
|
7TAA260100R0027
|
FLOOD SEAL MECH.SPLICE KIT 500 TIN (Flood Seal, Aluminum Mechanical Splice kit, Marked for Conductor Ranges 2/0-500 kcmil, Aluminum and Copper, Tin Plated, 7-1/2 inch long connector, 2 screws per side.)
|
ABB
|
|
7TAA260100R0025
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Tin Plated Aluminum Mechanical Splice Two-Wire Kits, conductor range 250-750 connector length 16-1/16 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0024
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 250-750 connector length 16-1/16 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0023
|
FS AL MECH SPLICE KIT #2-500 (Flood Seal, Aluminum Mechanical Splice kit, #2-500 kcmil, Aluminum and Copper, Aluminum Connector 4.5 inch long with Streetlight option, 1 screw per side)
|
ABB
|
|
7TAA260100R0022
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 2-500 connector length 16 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0021
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 2-500 connector length 12 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0020
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 2-500 connector length 7-1/2 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0019
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 2-500 connector length 4 3/16 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0018
|
FS AL MECH SPLICE KIT (Flood Seal, Aluminum Mechanical Splice kit, 1.81 inch long connector, #10 wire, 4 sides, 2 screws per side.)
|
ABB
|
|
7TAA260100R0017
|
ALUM MECHANICAL SPLICE 3WIRE KIT (Aluminum Flood-Seal Mechanical Splice Three-Wire Kits, conductor range side A 6-350, side B 1/0-4/0 with 6-14 solid tap, outlets accommodate 3 Wires)
|
ABB
|
|
7TAA260100R0016
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 4-4/0 connector length 2in, screws per side 1)
|
ABB
|
|
7TAA260100R0015
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 4 inch, screws per side 1)
|
ABB
|
|
7TAA260100R0014
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 18 inch, screws per side 1)
|
ABB
|
|
7TAA260100R0013
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 12 inch, screws per side 2)
|
ABB
|
|
7TAA260100R0012
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 12 inch, screws per side 1)
|
ABB
|
|
7TAA260100R0011
|
FS AL MECH SPLICE #6-350 (Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long)
|
ABB
|
|
7TAA260100R0010
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 2-9/16 inch, screws per side 1)
|
ABB
|
|
7TAA260100R0009
|
ALUM MECHANICAL SPLICE 2WIRE KIT (Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 14-2/0 connector length 1-1/2 inch, slotted screw, screws per side 1)
|
ABB
|
|
7TAA260080R0104
|
AL FloodSeal Splice Comp 2-350 (Aluminum Flood-Seal Mechanical Splice Compression Type Repair Kit, conductor range 2-350 standard one-hole lugs, cable length 17 1/2 inch)
|
ABB
|
|
7TAA260080R0103
|
Comp Lug Crimped INS Wire Roc/Cap (Compression Lugs Crimped Onto Insulated Wire With Rockets/caps)
|
ABB
|
Òîâàðû
10561 - 10590 èç 23691
Íà÷àëî
|
Ïðåä.
|
351
352
353
354
355
|
Ñëåä. |
Êîíåö
|