7TAA207400R0013
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40248.)
|
ABB
|
|
7TAA207400R0012
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40238.)
|
ABB
|
|
7TAA207400R0011
|
RFCI PHASE C, GREY CASE W/BLK (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase C, Gray case with blk. Customer Specific Modication 40111.)
|
ABB
|
|
7TAA207400R0010
|
RFCI PHASE B, GREY CASE W/ BLK (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase B, Gray case with blk. Customer Specific Modication 40110)
|
ABB
|
|
7TAA207400R0009
|
RFCI PHASE A, GREY CASE W/BLK (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase A, Gray Case with Blk. Customer Specific Modication 40109.)
|
ABB
|
|
7TAA207400R0008
|
RFCI PHASE C, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, Phase C. Customer Specific Modication 40051.)
|
ABB
|
|
7TAA207400R0007
|
RFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase B, Adaptive Trip. Customer Specific Modication 40050.)
|
ABB
|
|
7TAA207400R0006
|
RFCI PHASE C, ADAP DELAY TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase C, Adaptive Delay Trip. Customer Specific Modication 40036.)
|
ABB
|
|
7TAA207400R0005
|
RFCI PHASE B, ADAP DELAY TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase B, Adaptive Delay Trip. Customer Specific Modication 40035.)
|
ABB
|
|
7TAA207400R0004
|
RFCI PHASE A, ADAP DELAY TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase A, Adaptive Delay Trip. Customer Specific Modication 40034.)
|
ABB
|
|
7TAA207400R0003
|
RFCI 303.825 MHZ, PHASE C,ADAP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 303.825 MHZ, Phase C, Adaptive trip. Customer Specific Modication 39997.)
|
ABB
|
|
7TAA207400R0002
|
RFCI 303.825 MHZ, PHASE B,ADAP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 303.825 MHZ, Phase B, Adaptive trip. Customer Specific Modication 39996.)
|
ABB
|
|
7TAA207400R0001
|
RFCI 303.825 MHZ, ADAP TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 303.825 MHZ, Adaptive Trip. Customer Specific Modication 39842.)
|
ABB
|
|
7TAA207400R0000
|
FCI, LED, 600 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. LED, 600 Amps, Undelay. Customer Specific Modication 39750.)
|
ABB
|
|
7TAA201290R0000
|
SEL 651R CONTROL0651R125BAX21113G1
|
ABB
|
|
7TAA201180R0005
|
SEL 651R CONTROL
|
ABB
|
|
7TAA201160R0066
|
SEL 651R CONTROL
|
ABB
|
|
7TAA201160R0009
|
SEL 651R CONTROL
|
ABB
|
|
7TAA200590R0507
|
LINE POST SENSOR, 35KV W/10FTLEADS (35kv, 1301 Line Post Current Sensor with 10 foot leads, carries current.)
|
ABB
|
|
7TAA200590R0502
|
CURRENT SENSOR,35KV W/2-PIN CONNECT (Line Post Current Sensor, 35kV, Unit has coil internally grounded to base, 0.5 foot long cable with 2-pin amphenol connector on the end. Current carrying greater than 1000V. Made in USA. Customer Specific Modifications - CS1948.)
|
ABB
|
|
7TAA200590R0492
|
LINE POST SENSOR 25KV 60FT EXT. (Series 1301 PowerFlex High Accuracy Line-Post Sensors, 25kV, 60 Foot Cable.)
|
ABB
|
|
7TAA200590R0490
|
LINE POST SENSOR 25KV 45FT LEADS (Series 1301 PowerFlex High Accuracy Line-Post Sensors, 25kV, 45 Foot Cable.)
|
ABB
|
|
7TAA200590R0489
|
LINE POST CURRENT SENSOR,35KV (35Kv Fisher Pierce line current sensor (60A/V) with Amphenol connector on base, 16 foot sensor cable terminated at J-box end with 2-Pin MIL-DTL-5015, Type 10SL-4P, male weatherproof threaded connector receptacle wired as : Pin A - Sensor Low is Red, Pin B - Sensor High is Black. Carries current. Made in the USA. Customer Specific Modifications - CS1852.)
|
ABB
|
|
7TAA200590R0486
|
LINE-POST CURRENT SENSOR 15KV 45FT (Series 1301 PowerFlex High Accuracy Line-Post Sensors, 15kV, 45 Foot Cable.)
|
ABB
|
|
7TAA200590R0482
|
LINE POST SENSOR,25KV,W/5FT LEADS (Series 1301 PowerFlex High Accuracy Line-Post Sensors, 25kV, 5 Foot Cable.)
|
ABB
|
|
7TAA200590R0480
|
LINE POST SENSOR ASSEMBLY 15KV 25FT (Series 1301 PowerFlex High Accuracy Line-Post Sensors, 15kV, 25 Foot Cable.)
|
ABB
|
|
7TAA200590R0338
|
RTU RECEIVER, SINGLE OUTPUT (Remote Terminal Unit (RTU) Receiver, Single Output. Made in USA. Fixed Mount. Frequency 312 MHz, Range 100 Foot maximum, Power 9-12VDC, 20mA external, Complies with FCC Part 15 Emissions. RTU/SCADA Radio Receiver with (1) dry contact outputs for Phase A, B and C. With Technical Details on Document 39446.)
|
ABB
|
|
7TAA200590R0337
|
RTU RECEIVER, SINGLE OUTPUT (Remote Terminal Unit (RTU) Receiver, Single Output. Made in USA. Fixed Mount. Frequency 312 MHz, Range 100 Foot maximum, Power 9-12VDC, 20mA external, Complies with FCC Part 15 Emissions. RTU/SCADA Radio Receiver with (3) dry contact outputs for Phase A, B and C. With Technical Details on Document 40319.)
|
ABB
|
|
7TAA200590R0336
|
LINE POST CURRENT SENSOR, 25KV (Line post current sensor, 25kv, the unit has coil internally grounded to base. Base has special labels attached per customers specifications. Base has two pin MS connector attached and mating connector with 20 foot cable attached. Cable has shield needs to be connected to earth to shield cable. unit will also come with Midsun wildlife animal guard, Midsun part number - FPS Cover. This control is used in a system that carries current. Made in the USA. With Technical Details on Document 45144.)
|
ABB
|
|
7TAA200590R0335
|
LINE POST SENSOR,25KV,10FT W/CONNEC (Line Post Current Sensor, 25kV, Unit has coil internally grounded to base, 10 foot long cable with 2-pin amphenol connector on the end. Current carrying. Made in USA. Customer Specific Modifications - CS1748.)
|