7TAA207400R0043
|
RFCI PHASE A, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip))
|
ABB
|
|
7TAA207400R0042
|
FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec, di/dt adaptive trip). Single ultra bright LED display)
|
ABB
|
|
7TAA207400R0041
|
ADAPTIVE TRIP, 100 AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip). 5 ultra bright LEDs display)
|
ABB
|
|
7TAA207400R0040
|
FCI,ADAPTIVE TRIP, 300DI/DT (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 Hour automatic. (Factory Code 3). (Indicator Option X) Temporary fault indicator option - 4 Red, 1 Amber LEDs - standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter. (Factory Code A). (Temporary Fault Reset TIme Option 4) 24 Hours.)
|
ABB
|
|
7TAA207400R0039
|
FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 Hour automatic. (Indicator Option L) Single ultra-bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter, - not available for L Indicator Options.)
|
ABB
|
|
7TAA207400R0038
|
FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset TIme/Delay Option N) 4 hour automatic Reset Time-Delay. (Factory Code 3). (Indicator Option L) Single ultra-bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter, - not available for L Indicator Options. (Factory Code A).)
|
ABB
|
|
7TAA207400R0037
|
FCI, ADAPTIVE TRIP, 4HR TIME (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load curent, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Reset Time-Delay Option T) Manual reset only, most commonly used with Flag model since batteries are not used for indication, requires tool AT2186-10. (Indicator Option L) Single ultra-bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder N) No transmitter, - not available for L Indicator Options. 4 Hour Reset Time.)
|
ABB
|
|
7TAA207400R0036
|
RFCI PHASE C, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase C, Adaptive Trip. Customer Specific Modication 45118)
|
ABB
|
|
7TAA207400R0035
|
EFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase B, Adaptive Trip. Customer Specific Modication 45117)
|
ABB
|
|
7TAA207400R0034
|
RFCI PHASE A, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase A, Adaptive Trip. Customer Specific Modication 45116.)
|
ABB
|
|
7TAA207400R0033
|
FCI,50A TRIP,INRUSH 12HR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp Trip, Inrush 12 Hour delay. Customer Specific Modication 45107.)
|
ABB
|
|
7TAA207400R0032
|
FCI,ADAPTIVE TRIP,DELAY TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, Delay Trip. Customer Specific Modication 45103.)
|
ABB
|
|
7TAA207400R0031
|
FAULT INDICATOR, 50AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp DI/DT. Customer Specific Modication 45101.)
|
ABB
|
|
7TAA207400R0030
|
FAULT INDICATOR, 50AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp DI/DT. Customer Specific Modication 45100.)
|
ABB
|
|
7TAA207400R0029
|
FAULT INDICATOR, 50AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp DI/DT. Customer Specific Modication 45099.)
|
ABB
|
|
7TAA207400R0028
|
FCI, LED, 800 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. LED, 800 Amps, Undelay. Customer Specific Modication 45095.)
|
ABB
|
|
7TAA207400R0027
|
FCI, FIXED TRIP, 800 AMP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Fixed trip, 800 Amp. Customer Specific Modication 45094.)
|
ABB
|
|
7TAA207400R0026
|
FCI,44 KV, BF RESTR., 100A (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 44 Kv, Backfeed Restraint, 100 Amp. Customer Specific Modication 45020.)
|
ABB
|
|
7TAA207400R0025
|
FCI,ADAP TRIP,100A DI/DT,BKFD, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, 100 Amp DI/DT, Backfeed. Customer Specific Modication 45018.)
|
ABB
|
|
7TAA207400R0024
|
FCI,16 HR DELAY,CURRENT RESET, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 16 hour delay, Current Reset. Customer Specific Modication 45011.)
|
ABB
|
|
7TAA207400R0023
|
FCI, LED, 12 HR, 50 A DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. LED, 12 Hour Delay, 50 Amp DI/DT. Customer Specific Modication 45008.)
|
ABB
|
|
7TAA207400R0022
|
FCI, ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip. Customer Specific Modication 40589.)
|
ABB
|
|
7TAA207400R0021
|
RFCI, PHASE IN. C IN. , ADAPT.TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase IN. C IN, Adaptive Trip. Customer Specific Modication 40571.)
|
ABB
|
|
7TAA207400R0020
|
RFCI, PHASE IN. B IN. , ADAPT.TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase IN. B IN, Adaptive Trip. Customer Specific Modication 40570.)
|
ABB
|
|
7TAA207400R0019
|
RFCI, PHASE IN. A IN. , ADAPT.TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase IN. A IN, Adaptive Trip. Customer Specific Modication 40569.)
|
ABB
|
|
7TAA207400R0018
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40491.)
|
ABB
|
|
7TAA207400R0017
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40354.)
|
ABB
|
|
7TAA207400R0016
|
ADAPTIVE & FIXED TRIP FCI, 4HR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive and Fixed trip, 4 hour delay. Customer Specific Modication 40273.)
|
ABB
|
|
7TAA207400R0015
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40250.)
|
ABB
|
|
7TAA207400R0014
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40249.)
|
ABB
|