7TAA207400R0043 RFCI PHASE A, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip)) ABB
7TAA207400R0042 FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec, di/dt adaptive trip). Single ultra bright LED display) ABB
7TAA207400R0041 ADAPTIVE TRIP, 100 AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip). 5 ultra bright LEDs display) ABB
7TAA207400R0040 FCI,ADAPTIVE TRIP, 300DI/DT (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 Hour automatic. (Factory Code 3). (Indicator Option X) Temporary fault indicator option - 4 Red, 1 Amber LEDs - standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter. (Factory Code A). (Temporary Fault Reset TIme Option 4) 24 Hours.) ABB
7TAA207400R0039 FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 Hour automatic. (Indicator Option L) Single ultra-bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter, - not available for L Indicator Options.) ABB
7TAA207400R0038 FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset TIme/Delay Option N) 4 hour automatic Reset Time-Delay. (Factory Code 3). (Indicator Option L) Single ultra-bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter, - not available for L Indicator Options. (Factory Code A).) ABB
7TAA207400R0037 FCI, ADAPTIVE TRIP, 4HR TIME (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load curent, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Reset Time-Delay Option T) Manual reset only, most commonly used with Flag model since batteries are not used for indication, requires tool AT2186-10. (Indicator Option L) Single ultra-bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder N) No transmitter, - not available for L Indicator Options. 4 Hour Reset Time.) ABB
7TAA207400R0036 RFCI PHASE C, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase C, Adaptive Trip. Customer Specific Modication 45118) ABB
7TAA207400R0035 EFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase B, Adaptive Trip. Customer Specific Modication 45117) ABB
7TAA207400R0034 RFCI PHASE A, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase A, Adaptive Trip. Customer Specific Modication 45116.) ABB
7TAA207400R0033 FCI,50A TRIP,INRUSH 12HR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp Trip, Inrush 12 Hour delay. Customer Specific Modication 45107.) ABB
7TAA207400R0032 FCI,ADAPTIVE TRIP,DELAY TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, Delay Trip. Customer Specific Modication 45103.) ABB
7TAA207400R0031 FAULT INDICATOR, 50AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp DI/DT. Customer Specific Modication 45101.) ABB
7TAA207400R0030 FAULT INDICATOR, 50AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp DI/DT. Customer Specific Modication 45100.) ABB
7TAA207400R0029 FAULT INDICATOR, 50AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 50 Amp DI/DT. Customer Specific Modication 45099.) ABB
7TAA207400R0028 FCI, LED, 800 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. LED, 800 Amps, Undelay. Customer Specific Modication 45095.) ABB
7TAA207400R0027 FCI, FIXED TRIP, 800 AMP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Fixed trip, 800 Amp. Customer Specific Modication 45094.) ABB
7TAA207400R0026 FCI,44 KV, BF RESTR., 100A (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 44 Kv, Backfeed Restraint, 100 Amp. Customer Specific Modication 45020.) ABB
7TAA207400R0025 FCI,ADAP TRIP,100A DI/DT,BKFD, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, 100 Amp DI/DT, Backfeed. Customer Specific Modication 45018.) ABB
7TAA207400R0024 FCI,16 HR DELAY,CURRENT RESET, (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 16 hour delay, Current Reset. Customer Specific Modication 45011.) ABB
7TAA207400R0023 FCI, LED, 12 HR, 50 A DI/DT (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. LED, 12 Hour Delay, 50 Amp DI/DT. Customer Specific Modication 45008.) ABB
7TAA207400R0022 FCI, ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip. Customer Specific Modication 40589.) ABB
7TAA207400R0021 RFCI, PHASE IN. C IN. , ADAPT.TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase IN. C IN, Adaptive Trip. Customer Specific Modication 40571.) ABB
7TAA207400R0020 RFCI, PHASE IN. B IN. , ADAPT.TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase IN. B IN, Adaptive Trip. Customer Specific Modication 40570.) ABB
7TAA207400R0019 RFCI, PHASE IN. A IN. , ADAPT.TRIP (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Phase IN. A IN, Adaptive Trip. Customer Specific Modication 40569.) ABB
7TAA207400R0018 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40491.) ABB
7TAA207400R0017 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40354.) ABB
7TAA207400R0016 ADAPTIVE & FIXED TRIP FCI, 4HR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive and Fixed trip, 4 hour delay. Customer Specific Modication 40273.) ABB
7TAA207400R0015 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40250.) ABB
7TAA207400R0014 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40249.) ABB