7TAA207400R0073 FCI, ADAPT TRIP, 24HR RESET (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 hour automatic. (Factory Code 3). (Indicator Option L) Single ultra bright LED standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0072 FCI,BK. FEED,100A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option C) Phase C. (Factory Code A).) ABB
7TAA207400R0071 FCI,BK. FEED,100A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option B) Phase B. (Factory Code A).) ABB
7TAA207400R0070 FCI,BK. FEED,100A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option A) Phase A. (Factory Code A).) ABB
7TAA207400R0069 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option T) Manual Reset Only, most commonly used with Flag model since batteries are not used for indication, requires tool AT2186-10. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0068 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option C) Phase C. (Factory Code A).) ABB
7TAA207400R0067 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option B) Phase B. (Factory Code A).) ABB
7TAA207400R0066 FAULT INDICATORS (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option A) Phase A. (Factory Code A).) ABB
7TAA207400R0065 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator Main Feeder (3 Amp minimum load, 100A increase di/dt adaptive trip, 24-msec. delay for backfeed restraint)) ABB
7TAA207400R0064 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwisw no automatic reset. (Factory Code 3). (Indicator Option T) Strobe Light for applications up to 44kV. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0063 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override 60 seconds after restoration of power. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option C) Phase C. (Factory Code A).) ABB
7TAA207400R0062 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override 60 seconds after restoration of power. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option B) Phase B. (Factory Code A).) ABB
7TAA207400R0061 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override 60 seconds after restoration of power. (Factory Code 3). (Indicator Option R) Radio with single LED for applications up to 69kV. (Transmitter Phase Encoder Option A) Phase A. (Factory Code A).) ABB
7TAA207400R0060 FCI,ADAPTIVE TRIP,300AMP DI/DT (Series 1548 Overhead Faulted Circuit Indicator Main Feeder (3 Amp minimum load, 300A di/dt adaptive trip, 24-msec. delay for backfeed restraint)) ABB
7TAA207400R0059 FCI, ADAPTIVE TRIP, 60 SECONDS (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwise no automatic reset. (Factory Code 3). (Indicator Option T) Strobe Light for applications up to 44kV. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0058 FCI, ADAPTIVE TRIP, 60 SECONDS (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwise no automatic reset. (Factory Code 3). (Indicator Option L) Single ultra bright LED, standard for applications up to 69kV. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0057 FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip)) ABB
7TAA207400R0056 FCI, OVERHEAD, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option T) Strobe Light for applications up to 44kV maximum. (Factory Code 3). (Indicator Option L) Single ultra bright LED, standard for applications up to 69kV. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0055 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option T) Strobe Light for applications up to 44kV maximum. (Transmitter Phase Encoder Option N) No Transmitter.) ABB
7TAA207400R0054 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option T) Strobe Light for applications up to 44kV maximum. (Factory Code 3). (Indicator Option F) Flag for applications up to 44kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0053 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 hour automatic. (Factory Code 3). (Indicator Option L) Single Ultra bright LED, standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0052 FCI, OVERHEAD, STROBE, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option T) Strobe Light, for applications up to 44kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).) ABB
7TAA207400R0051 RFCI PHASE C, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) Radio with single LED, for applications up to 69kV maximum. (Transmitter Phase Encoder Option C) Phase C. (Factory Code A).) ABB
7TAA207400R0050 EFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) Radio with single LED, for applications up to 69kV maximum. (Transmitter Phase Encoder Option B) Phase B. (Factory Code A).) ABB
7TAA207400R0049 RFCI PHASE A, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) Radio with single LED, for applications up to 69kV maximum. (Transmitter Phase Encoder Option A) Phase A. (Factory Code A).) ABB
7TAA207400R0048 FCI, ADAPTIVE TRIP, 4HR TIME (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip)) ABB
7TAA207400R0047 FCI, OVERHEAD, STROBE, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip). Strobe Light) ABB
7TAA207400R0046 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip). Radio with single LED for applications up to 69kV maximum, Tap Transmitter Phase Encoder) ABB
7TAA207400R0045 RFCI PHASE C, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip). Radio with single LED for applications up to 69kV maximum) ABB
7TAA207400R0044 RFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip)) ABB