7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA207400R0115
|
RFCI, PH. A, UNDELY, 400A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 400 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0114
|
FCI,NON-INRUSH UNDELAY,400A (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 400 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0113
|
1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 200 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.)
|
ABB
|
|
7TAA207400R0112
|
1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 200 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.)
|
ABB
|
|
7TAA207400R0111
|
1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 200 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0098
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 400 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single Ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0097
|
FCI, LED, 200 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 200 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single Ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0096
|
FCI, LED, 200 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 200 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single Ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0095
|
FCI, LED, UNDELAY, 100 AMP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option Z - 60 seconds after restoration of power, otherwise no automatic reset. Indicator option L - Single Ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0094
|
FCI, LED, 100 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option T - Manual reset only, requires tool AT2186-10. Indicator option L - Single Ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0093
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option T - Manual reset only, requires tool AT2186-10. Indicator option F - Flag (for applications up to 44kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0092
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N 0 No transmitter.)
|
ABB
|
|
7TAA207400R0091
|
FCI, LED/RADIO,PHASE A 100 A, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option C - 4 hour automatic with current reset override (60 seconds after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0090
|
FCI, UNDELAYED, 50A TRIP, (Series 1548 Overhead Faulted Circuit Indicator (3 Amp minimum load, 50A Fixed Trip, Undelayed current trip))
|
ABB
|
|
7TAA207400R0089
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 50 Amps. Reset Time Delay option N - 24 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0088
|
FCI, LED, 600 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option D - Fixed Trip, 32 msec. delayed trip plus/minus 20 percent, current trip plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 600 Amps. Reset time delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0087
|
FCI, TRIP DELAY, 4HRS (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option D - Fixed Trip, 32 msec. delayed trip plus/minus 20 percent, current trip plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 600 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 seconds after restoration or power). Indicator option T - Strobe light (for applications up to 44kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0086
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option D - Fixed Trip, 32 msec. delayed trip plus/minus 20 percent, current trip plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 300 Amps. Reset time delay option P - 24 hour automatic. Indicator option L - Single ultro bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0085
|
FCI, 200A TRIP, RADIO, TAP, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option D - Fixed Trip, 32 msec. delayed trip plus/minus 20 percent, current trip plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 200 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 seconds after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option T - Tap. Temporary Fault Reset Time option A - Temporary Fault not selected.)
|
ABB
|
|
7TAA207400R0084
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option D - Fixed Trip, 32 msec. delayed trip plus/minus 20 percent, current trip plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 100 Amps. Reset time delay option P - 24 hour automatic. Indicator option L - Single ultro bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0083
|
FCI, LED, 1200 AMPS, UNDELAY, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option D - Fixed Trip, 32 msec. delayed trip plus/minus 20 percent, current trip plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 1200 Amps. Reset time delay option N - 4 hour automatic. Indicator option L - Single ultro bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0082
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator (3 Amp minimum load, 50Amp Fixed Trip, 32 msec. delayed trip +/-20 percent))
|
ABB
|
|
7TAA207400R0081
|
FCI,FIXED TRIP,4HR RESET,CUR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 800 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option T - Tap.)
|
ABB
|
|
7TAA207400R0080
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 800 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.)
|
ABB
|
|
7TAA207400R0079
|
FCI, INRUSH, LED, 600AMP TRIP, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 600 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0078
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 200 Amps. Reset time delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0077
|
FCI, INRUSH, LED, 60 AMP TRIP, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 60 Amps. Reset time delay option P - 24 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0076
|
FAULT INDCIATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 50 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 seconds after restoration of power). Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0075
|
FCI, ADAPTIVE TRIP, MAN. RESET (Series 1548 Overhead Faulted Circuit Indicator Main Feeder (3 Amp minimum load, 100A increase di/dt adaptive trip, 24-msec. delay for backfeed restraint))
|
ABB
|
|
7TAA207400R0074
|
FCI,ADAPTIVE TRIP,DELAY TRIP (Series 1548 Overhead Faulted Circuit Indicator Main Feeder (3 Amp minimum load, 100A increase di/dt adaptive trip, 24-msec. delay for backfeed restraint))
|
ABB
|