7TAA207400R0145 FCI W/75MS BACKFEED RESTRAINT, PH C (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. With 75 MS backfeed restraint, Phase C. Customer Specific Modication 45098.) ABB
7TAA207400R0144 FCI W/75MS BACKFEED RESTRAINT, PH B (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. With 75 MS backfeed restraint, Phase B. Customer Specific Modication 45097.) ABB
7TAA207400R0143 FCI W/75MS BACKFEED RESTRAINT, PH A (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. With 75 MS backfeed restraint, Phase A. Customer Specific Modication 45096.) ABB
7TAA207400R0142 FCI,OVERHEAD,ADAPTIVE TRIP,4HR RSET (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Overhead, Adaptive Trip, 4 hour reset. Customer Specific Modication 45080.) ABB
7TAA207400R0141 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40355.) ABB
7TAA207400R0140 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40353.) ABB
7TAA207400R0139 FCI, ADAPTIVE TRIP, 2 HR DELAY (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, 2 hour delay. Customer Specific Modication 40081.) ABB
7TAA207400R0138 FCI, ADAP TRIP,OVERHEAD, RADIO (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, overhead, Radio. Customer Specific Modication 40049.) ABB
7TAA207400R0137 FCI,ADAP TRIP,OVERHEAD,AUTO RESET (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, Auto Reset, Overhead. Customer Specific Modication 40044.) ABB
7TAA207400R0136 FP SERIES 1548 OVERHEAD FCI (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 39564.) ABB
7TAA207400R0135 FISHER PIERCE OVERHEAD FCI (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 200 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207400R0134 FCI,BK. FEED,300A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option C - Phase C.) ABB
7TAA207400R0133 FCI,BK. FEED,300A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0132 FCI,BK. FEED,300A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option A - Phase A.) ABB
7TAA207400R0131 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option N - No Transmitter.) ABB
7TAA207400R0130 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV manimum). Transmitter Phase Encoder option C - Phase C.) ABB
7TAA207400R0129 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV manimum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0128 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV manimum). Transmitter Phase Encoder option A - Phase A.) ABB
7TAA207400R0127 FAULT INDICATOR (Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required. Available with adaptive trip logic only.) ABB
7TAA207400R0126 FCI,ADAPTIVE TRIP,DELAY TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option P - 24 hour automatic. Indicator option X - Temporary fault indication option 4 red, 1 amber LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter. Temporary Fault Reset Time option 4 - 24 Hours.) ABB
7TAA207400R0125 FCI,FLAG,ADAPTIVE TRIP,24HR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option P - 24 hour automatic. Indicator option F - Flag (for applications up to 44kV maximum). Transmitter Phase Encoder option N - No Transmitter.) ABB
7TAA207400R0124 RFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0123 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.) ABB
7TAA207400R0122 FAULT INDICATOR (Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required. Available with adaptive trip logic only.) ABB
7TAA207400R0121 FCI,ADAPTIVE TRIP, 5-LED, FAST (Series 1514 Faulted Circuit Indicator, Special Application Offering for temporary fault detection where reclose recognition time of 32 msec. is required. Recommended for circuits with fast protection settings capable of opening and reclosing in less that 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Adaptive Trip, 5-LEDs, Fast. Customer Specific Modication 45071.) ABB
7TAA207400R0120 1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option Z - 60 second after restoration of power, otherwise no automatic reset. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.) ABB
7TAA207400R0119 1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option Z - 60 second after restoration of power, otherwise no automatic reset. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0118 1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option Z - 60 second after restoration of power, otherwise no automatic reset. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.) ABB
7TAA207400R0117 RFCI, PH. C, UNDELY, 600A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.) ABB
7TAA207400R0116 FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.) ABB