7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA207400R0145
|
FCI W/75MS BACKFEED RESTRAINT, PH C (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. With 75 MS backfeed restraint, Phase C. Customer Specific Modication 45098.)
|
ABB
|
|
7TAA207400R0144
|
FCI W/75MS BACKFEED RESTRAINT, PH B (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. With 75 MS backfeed restraint, Phase B. Customer Specific Modication 45097.)
|
ABB
|
|
7TAA207400R0143
|
FCI W/75MS BACKFEED RESTRAINT, PH A (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. With 75 MS backfeed restraint, Phase A. Customer Specific Modication 45096.)
|
ABB
|
|
7TAA207400R0142
|
FCI,OVERHEAD,ADAPTIVE TRIP,4HR RSET (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Overhead, Adaptive Trip, 4 hour reset. Customer Specific Modication 45080.)
|
ABB
|
|
7TAA207400R0141
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40355.)
|
ABB
|
|
7TAA207400R0140
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 40353.)
|
ABB
|
|
7TAA207400R0139
|
FCI, ADAPTIVE TRIP, 2 HR DELAY (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, 2 hour delay. Customer Specific Modication 40081.)
|
ABB
|
|
7TAA207400R0138
|
FCI, ADAP TRIP,OVERHEAD, RADIO (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, overhead, Radio. Customer Specific Modication 40049.)
|
ABB
|
|
7TAA207400R0137
|
FCI,ADAP TRIP,OVERHEAD,AUTO RESET (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Adaptive Trip, Auto Reset, Overhead. Customer Specific Modication 40044.)
|
ABB
|
|
7TAA207400R0136
|
FP SERIES 1548 OVERHEAD FCI (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 39564.)
|
ABB
|
|
7TAA207400R0135
|
FISHER PIERCE OVERHEAD FCI (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 200 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.)
|
ABB
|
|
7TAA207400R0134
|
FCI,BK. FEED,300A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option C - Phase C.)
|
ABB
|
|
7TAA207400R0133
|
FCI,BK. FEED,300A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option B - Phase B.)
|
ABB
|
|
7TAA207400R0132
|
FCI,BK. FEED,300A DI/DT,RADI0 (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0131
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0130
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV manimum). Transmitter Phase Encoder option C - Phase C.)
|
ABB
|
|
7TAA207400R0129
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV manimum). Transmitter Phase Encoder option B - Phase B.)
|
ABB
|
|
7TAA207400R0128
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with single LED (for applications up to 69kV manimum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0127
|
FAULT INDICATOR (Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required. Available with adaptive trip logic only.)
|
ABB
|
|
7TAA207400R0126
|
FCI,ADAPTIVE TRIP,DELAY TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option P - 24 hour automatic. Indicator option X - Temporary fault indication option 4 red, 1 amber LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter. Temporary Fault Reset Time option 4 - 24 Hours.)
|
ABB
|
|
7TAA207400R0125
|
FCI,FLAG,ADAPTIVE TRIP,24HR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option P - 24 hour automatic. Indicator option F - Flag (for applications up to 44kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0124
|
RFCI PHASE B, ADAPTIVE TRIP, (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.)
|
ABB
|
|
7TAA207400R0123
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0122
|
FAULT INDICATOR (Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required. Available with adaptive trip logic only.)
|
ABB
|
|
7TAA207400R0121
|
FCI,ADAPTIVE TRIP, 5-LED, FAST (Series 1514 Faulted Circuit Indicator, Special Application Offering for temporary fault detection where reclose recognition time of 32 msec. is required. Recommended for circuits with fast protection settings capable of opening and reclosing in less that 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Adaptive Trip, 5-LEDs, Fast. Customer Specific Modication 45071.)
|
ABB
|
|
7TAA207400R0120
|
1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option Z - 60 second after restoration of power, otherwise no automatic reset. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.)
|
ABB
|
|
7TAA207400R0119
|
1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option Z - 60 second after restoration of power, otherwise no automatic reset. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.)
|
ABB
|
|
7TAA207400R0118
|
1548 FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option Z - 60 second after restoration of power, otherwise no automatic reset. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.)
|
ABB
|
|
7TAA207400R0117
|
RFCI, PH. C, UNDELY, 600A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.)
|
ABB
|
|
7TAA207400R0116
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 600 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
Òîâàðû
5251 - 5280 èç 23691
Íà÷àëî
|
Ïðåä.
|
174
175
176
177
178
|
Ñëåä. |
Êîíåö
|