7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA207400R0175
|
1548,OVERHEAD FCI, 500A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 500 Amps. Reset time delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter. Temporary Fault Reset Time option A - Temporaru Fault not selected.)
|
ABB
|
|
7TAA207400R0174
|
FCI,OVERHEAD,FIXED TRIP,400A,LED (Series 1548 Overhead Faulted Circuit Indicator (3 Amp minimum load, 400A Fixed Trip, Inrush restraint active for 32 msec. from power up))
|
ABB
|
|
7TAA207400R0173
|
FCI, 200A TRIP, 24HR RESET, LED (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 200 Amps. Reset time delay option P - 24 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.)
|
ABB
|
|
7TAA207400R0172
|
FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator (3 Amp minimum load, 200A Fixed Trip, Inrush restraint active for 32 msec. from power up))
|
ABB
|
|
7TAA207400R0171
|
FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 200 Amps. Reset time delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B. Temporary Fault Reset Time option A - Temporaru Fault not selected.)
|
ABB
|
|
7TAA207400R0170
|
FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 200 Amps. Reset time delay option N - 4 hour automatic. Indicator option R - Radio with Single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A. Temporary Fault Reset Time option A - Temporaru Fault not selected.)
|
ABB
|
|
7TAA207400R0169
|
FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 100 Amps. Reset time delay option C - 4 hour automatic with current reset override (50 seconds after restoration of power). Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0168
|
FCI, 1500A FIX TRIP, 4 HR RESET (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 1500 Amps. Reset time delay option C - 4 hour automatic with current reset override (50 seconds after restoration of power). Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0167
|
FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 50 Amps. Reset time delay option Z - 60 seconds after restoration of power, otherwize no automatic reset. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.)
|
ABB
|
|
7TAA207400R0166
|
FCI,100DI/DT,BACKFEED,4HR,STROBE (Series 1548 Overhead Faulted Circuit Indicator Main Feeder (3 Amp minimum load, 100A increase di/dt adaptive trip, 24-msec. delay for backfeed restraint))
|
ABB
|
|
7TAA207400R0165
|
OVERHEAD FCI,ADAPTIVE TRIP,LED (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option L) Single ultra bright LED standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).)
|
ABB
|
|
7TAA207400R0164
|
OH FCI ADAPTIVE TRIP 5 LED (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option J) 5 Ultra bright LEDs display for applications up to 69kV. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).)
|
ABB
|
|
7TAA207400R0163
|
OVERHEAD FAULT CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) radio with SIngle LED for applications up to 69kV. (Transmitter Phase Encoder Option C) Phase C. (Factory Code A).)
|
ABB
|
|
7TAA207400R0162
|
OVERHEAD FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) radio with SIngle LED for applications up to 69kV. (Transmitter Phase Encoder Option B) Phase B. (Factory Code A).)
|
ABB
|
|
7TAA207400R0161
|
OVERHEAD FAULT CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option R) radio with SIngle LED for applications up to 69kV. (Transmitter Phase Encoder Option A) Phase A. (Factory Code A).)
|
ABB
|
|
7TAA207400R0160
|
OVERHEAD FCI W/ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option B) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current, with 24 ms plus/minus 20 percent delay trip - backfeed restraint. (Trip/Current Option D) 300 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Indicator Option L) SIngle Ultra bright LED standard applications up to 69kV. (Transmitter Phase Encoder Option N) No Transmitter.)
|
ABB
|
|
7TAA207400R0159
|
FCI, ADAPTIVE, TEMPORARY FAULT (Series 1548 Overhead Faulted Circuit Indicator Main Feeder (3 Amp minimum load, 300A di/dt adaptive trip, 24-msec. delay for backfeed restraint))
|
ABB
|
|
7TAA207400R0158
|
FP SERIES 1548 OVERHEAD FCI (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwise no automatic reset. (Indicator Option R) Radio with Single LED, standard for applications up to 69kV. (Transmitter Phase Encoder Option C) Phase C.)
|
ABB
|
|
7TAA207400R0157
|
FP SERIES 1548 OVERHEAD FCI (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwise no automatic reset. (Indicator Option R) Radio with Single LED, standard for applications up to 69kV. (Transmitter Phase Encoder Option B) Phase B.)
|
ABB
|
|
7TAA207400R0156
|
FP 1548 OVERHEAD FCI W/ RADIO (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwise no automatic reset. (Indicator Option R) Radio with Single LED, standard for applications up to 69kV. (Transmitter Phase Encoder Option A) Phase A.)
|
ABB
|
|
7TAA207400R0155
|
FCI, ADAPTIVE TRIP, 4 HR RESET TIME (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, otherwise no automatic reset. (Indicator Option L) Single ultra bright LED, standard for applications up to 69kV. (Transmitter Phase Encoder Option N) No Transmitter.)
|
ABB
|
|
7TAA207400R0154
|
OH FCI WITH 24 HR RESET TEMP FALUT (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip))
|
ABB
|
|
7TAA207400R0153
|
OH FCI WITH 24HR AUTO RESET (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option P) 24 hour automatic. (Factory Code 3). (Indicator Option J) 5 Ultra bright LEDs display, for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A).)
|
ABB
|
|
7TAA207400R0152
|
1548 OVERHEAD FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option X) Temporary fault indication option - 4 Red, 1 Amber LEDs - standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No Transmitter. (Factory Code A). (Temporary Fault Reset TIme Option 1) 4 hours.)
|
ABB
|
|
7TAA207400R0151
|
1548 OVERHEAD FCI,ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Indicator Option L) Single ultra bright LED display, standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter.)
|
ABB
|
|
7TAA207400R0150
|
OVERHEAD FCI, ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip))
|
ABB
|
|
7TAA207400R0149
|
FCI, ADAPTIVE TRIP, 100DI/DT, 4HR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option X) Temporary fault indication option - 4 Red, 1 Amber LEDs - standard for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter, - not available for T Indicator Options. (Factory Code A). (Temporary Fault Reset TIme Option 2) 8 hours.)
|
ABB
|
|
7TAA207400R0148
|
FCI, ADAPTIVE TRIP, 100DI/DT, 4HR (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip))
|
ABB
|
|
7TAA207400R0147
|
FAULT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option D) 300 Amp di/dt main feeder applications, Note 3 Amp minimum load required. (Reset Time-Delay Option Z) 60 seconds after restoration of power, othewise no automatic reset. (Factory Code 3). (Indicator Option T) Strobe light - for applications up to 44kV maximum. (Transmitter Phase Encoder Option N) No transmitter, - not available for T Indicator Options. (Factory Code A).)
|
ABB
|
|
7TAA207400R0146
|
FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 45129.)
|
ABB
|