7TAA207410R0001 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 39016.) ABB
7TAA207410R0000 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 38728.) ABB
7TAA207400R0205 FCI 100A DI/DT LABEL (Series 1514 Faulted Circuit Indicator, Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Single Phase, 12 hour time delay with current override reset. Adaptive trip (100 Amp Di/DT) - Sticker saying 100 to distinguish which model. Current carrying greater than 1000 volts. Customer Specific modifications CS1907) ABB
7TAA207400R0204 FCI, 200A, 4-HOUR RESET ONLY, LED (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 200 Amps. Reset time delay option N - 4 hour automatic. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter.) ABB
7TAA207400R0203 FCI OVERHEAD ADAPTIVE TRIP 4HR TIME (Series 1548 Overhead Faulted Circuit Indicators. (Model F) Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. (Factory Code H). (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option N) 4 hour automatic. (Factory Code 3). (Indicator Option J) 5 ultra bright LEDs display, for applications up to 69kV maximum. (Transmitter Phase Encoder Option N) No transmitter. (Factory Code A).) ABB
7TAA207400R0202 FAULTED CIRCUIT INDICATOR (Series 1514 Faulted Circuit Indicator, Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Current-Reset FCI, Single Phase, 4 hour time delay with current override reset. Adaptive trip (100 Amp Di/DT) - Sticker saying 100 to distinguish which model. Current carrying greater than 1000 volts. Customer Specific modifications CS1803) ABB
7TAA207400R0199 OVERHEAD FCI, 800A TRIP, RADIO PH-C (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option C - Fixed Trip Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip Current option is 800 Amps. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option C - Phase C.) ABB
7TAA207400R0198 OVERHEAD FCI, 800A TRIP, RADIO PH-B (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option C - Fixed Trip Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip Current option is 800 Amps. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0197 OVERHEAD FCI, 800A TRIP, RADIO PH-A (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option C - Fixed Trip Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip Current option is 800 Amps. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option A - Phase A.) ABB
7TAA207400R0196 OVERHEAD FCI,TRIP,ADAPTIVE TRIP (Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required. Available with adaptive trip logic only.) ABB
7TAA207400R0195 FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option N - 100 Amp di/dt adaptive trip. Reset TIme/Delay option N - 4 hour automatic. Indicator option T - Strobe light (for applications up to 44kV manimum). Transmitter Phase Encoder option N - No transmitter.) ABB
7TAA207400R0194 1548,OVERHEAD FCI,ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option N - 100 Amp di/dt adaptive trip. Reset TIme/Delay option C - 4 hour automatic with current reset override (60 secodn after restoration of power). Indicator option X - Temporary fault indication option 4 red, 1 amber LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option N - No transmitter. Temporary Fault Reset Time option 1 - 4 hours.) ABB
7TAA207400R0193 OVERHEAD FCI W/ ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option P - 24 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option C - Phase C. Temporary Fault Reset Time option A - Temporary fault not selected.) ABB
7TAA207400R0192 OVERHEAD FCI WITH ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option P - 24 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option B - Phase B. Temporary Fault Reset Time option A - Temporary fault not selected.) ABB
7TAA207400R0191 OVERHEAD FCI W/ ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option B - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current, with 24ms. plus/minus 20 percent delay trip (backfeed restraint). Trip Current option D - 300 Amp di/dt main feeder applications. Reset TIme/Delay option P - 24 hour automatic. Indicator option R - Radio with Single LED (standard for applications up to 69kV manimum). Transmitter Phase Encoder option A - Phase A. Temporary Fault Reset Time option A - Temporary fault not selected.) ABB
7TAA207400R0190 FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option G - Special application offering for temporary fault detection where reclose recognition time of 32 msec. is required, Recommended for circuits with fast protection settings capable of opening and reclosing in less than 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. Trip/Inrush Logic option A - Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 seconds for fault current. Trip Current - Option N - 100 Amp Di/Dt adaptive trip. Reset Time/Delay option T - Manual Reset Only, requires tool AT2186-10. Indicator option L - Single ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter.) ABB
7TAA207400R0189 OVERHEAD FCI FOR 1PH APPLICATIONS (Series 1514 Faulted Circuit Indicator, Special Application Offering for temporary fault detection where reclose recognition time of 32 msec. is required. Recommended for circuits with fast protection settings capable of opening and reclosing in less that 10 cycles. Available with adaptive trip logic only. Requires 8 Amp minimum load current for reset. No current auto reset should be specified. (Trip/Inrush Logic Option A) Adaptive Trip requires 60 second continuous minimum load current, arming time less than 1/4 cycle fault current, loss of current within 60 second of fault current. (Trip/Current Option N) 100 Amp di/dt adaptive trip, Note 3 Amp minimum load required. (Reset Time-Delay Option C) 4 hour automatic with current reset override, 60 seconds after restoration of power. (Factory Code 3). (Indicator Option X) Temporary fault indicator option 4 Red, 1 Amber LEDs, standard for applications up to 69kV maximum. (Transmitter Phase Encoder option N) No Transmitter. (Factory Code A). (Temporary Fault Reset Time Option 1) 4 Hours.) ABB
7TAA207400R0188 FAULT INDICATOR (Series 1514 Faulted Circuit Indicator, Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modification 40339.) ABB
7TAA207400R0187 FCI, 800A FIXED TRIP, 8HR RESET (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic Option C - Fixed Trip, Inrush restraint active for 32 msec. from power up, thereafter, undelayed trip curve plus/minus 10 percent accuracy. Trip/Current - Fixed Current of 800 Amps. Reset time delay option C - 4 hour automatic with current reset override (60 second after restoration of power). Indicator option J - 5 ultra bright LEDs for increased visibility display (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No Transmitter. Customer Specific Modifications CS1732.) ABB
7TAA207400R0186 OVERHEAD FCI,ADAPTIVE TRIP (Series 1548 Overhead Faulted Circuit Indicator Branch Feeder (3 Amp minimum load, 100A increase within 50 msec. di/dt adaptive trip)) ABB
7TAA207400R0185 OVERHEAD FCI W/ FIXED TRIP,1PH APPL (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option Z - 60 seconds after restoration of power, otherwise no automatic reset. Indicator option L - Single Ultra bright LED (standard for applications up to 69kV maximum). Transmitter Phase Encoder option N - No transmitter. Termorary Fault Reset Time option A - Temporary fault not selected.) ABB
7TAA207400R0184 OVERHEAD FCI SERIES 1548 FIXED TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option T - Manual reset only, requires tool AT2186-10. Indicator option F - Flag (for applications up to 44kV maximum). Transmitter Phase Encoder option N - No transmitter.) ABB
7TAA207400R0183 RFCI, PH. C, UNDELAY, 100A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option C - Phase C.) ABB
7TAA207400R0182 FCI, RADIO, 100A, UNDELAYED, 4-HR (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0181 RFCI, PH. B, UNDELAY, 100A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 100 Amps. Reset Time Delay option N - 4 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option A - Phase A.) ABB
7TAA207400R0180 FP SERIES 1548 OVERHEAD FCI (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 1500 Amps. Reset Time Delay option T - Manual Reset only, requires tool AT2186-10. Indicator option F - Flag (for applications up to 44kV maximum). Transmitter Phase Encoder option N - No Transmitter.) ABB
7TAA207400R0179 RFCI, PH. B, UNDELY, 50A TRIP (Series 1548 Overhead Faulted Circuit Indicator, Basic Model Option F - Standard offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3.0 Amp minimum load current required for reset, adaptive and fixed inrush trip logic options available. Trip/Inrush Logic option U - Undelayed current trip plus/minus 10 percent accuracy, standard trip. Trip Current is 50 Amps. Reset Time Delay option N - 24 hour automatic. Indicator option R - Radio with single LED (for applications up to 69kV maximum). Transmitter Phase Encoder option B - Phase B.) ABB
7TAA207400R0178 FAULTED CIRCUIT INDICATOR (Series 1514 Faulted Circuit Indicator, Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Current-Reset FCI, Single Phase, 12 hour time delay with current override reset. Adaptive trip (50 Amp Di/DT) - Sticker saying 50 to distinguish which model. Current carrying greater than 1000 volts. Customer Specific modifications CS1796) ABB
7TAA207400R0177 FCI,ADAPTIVE 100A DI/DT,5 LED,8HR (Series 1548 Overhead Faulted Circuit Indicator, Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. 100 Amp DI/DT adaptive trip, 8 hour reset, 5 LEDS, carries current. Customer Specific modifications CS1793) ABB
7TAA207400R0176 OVERHEAD FCI W/ FIXED TRIP (Series 1548 Overhead Faulted Circuit Indicator (3 Amp minimum load, 800A Fixed Trip, Inrush restraint active for 32 msec. from power up)) ABB