7TAA207410R0031 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option Z - 60 second reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option M - 1.0 Amp (1-5/8 inch sensor with U-Lamination). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.) ABB
7TAA207410R0030 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option Z - 60 second reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option L - 1.5 Amp (2-3/16 inch sensor with U-Lamination). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.) ABB
7TAA207410R0029 FAULT INDICATOR (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator Flag Type. Flag with Manual Reset Delay. Hotstick Mount with Clamp. 60 sec. reset time delay after power restoration.) ABB
7TAA207410R0028 FAULT INDICATOR (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator Flag Type. Flag with Manual Reset Delay. Hotstick Mount with Clamp. 60 sec. reset time delay after power restoration.) ABB
7TAA207410R0027 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option W - 4 Hour reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option M - 1.0 Amp (1-5/8 inch sensor with U-Lamination). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.) ABB
7TAA207410R0026 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option W - 4 Hour reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option L - 1.5 Amp (2-3/16 inch sensor with U-Lamination). SCADA Output option N- No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity -Raised zero reference to 7A.) ABB
7TAA207410R0025 F.I. ADAPTIVE TRIP, 4HR DELAY, (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator Flag Type. Flag with Manual Reset Delay. Hotstick Mount with Clamp. 4 hr reset time delay after power restoration.) ABB
7TAA207410R0024 FAULT INDICATOR (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator Flag Type. Flag with Manual Reset Delay. Hotstick Mount with Clamp. 4 hr reset time delay after power restoration.) ABB
7TAA207410R0023 FCI, FLAG, HOTSTK,4HR RST-PWR, (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option W - 4 Hour reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option A - N.O. (10 foot lead). No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.) ABB
7TAA207410R0022 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option W - 4 Hour reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. No Lead between Sensor and Display. Close Proximity - Raised zero reference to 7A.) ABB
7TAA207410R0021 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option W - 4 Hour reset time delay after power restoration. Sensor Mounting Option T - Integral Hotstick. Reset Current Option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.) ABB
7TAA207410R0020 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option H - Hotstick mount with Clamp. Reset Delay Option R - Manual Reset Only. Sensor Mounting Option T - Integral Hotstick. Reset Current Option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.) ABB
7TAA207410R0019 FAULT INDICATOR (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator Flag Type. Flag with Manual Reset Delay. Hotstick Mount with Clamp. 24 hr reset time delay after power restoration.) ABB
7TAA207410R0018 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option B - Bracket/Surface Mount. Reset Delay Option Z - 60 second reset time delay after power restoration. Sensor Mounting option S - Remote Tie-Wrap. Reset Current option M - 1.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. 10 foot Lead. Close Proximity option N - Standard.) ABB
7TAA207410R0017 FCI, FLAG, BRACKET, 60 SEC. (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option B - Bracket/Surface Mount. Reset Delay Option Z - 60 second reset time delay after power restoration. Sensor Mounting option S - Remote Tie-Wrap. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. 10 foot Lead. Close Proximity option N - Standard.) ABB
7TAA207410R0016 FCI, ADAP TRIP, SCADA OUTPUT, (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option B - Bracket/Surface Mount. Reset Delay Option W - 4 hour reset time after power restoration. Sensor Mounting option S - Remote Tie-Wrap. Current Reset Option L - 1.5 Amp (2-3/16 inch sensor with U-lamination). SCASA Output Option A - N.O. 10 foot lead. Close Proximity Option R - Raised zero reference to 7A.) ABB
7TAA207410R0015 FCI, STD. CLOSE, 10' N.O SCADA (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator Flag Type. Flag with Manual Reset Delay. Bracket Surface Mount. 4 hr reset time delay after power restoration. 10 foot lead length. No SCADA) ABB
7TAA207410R0014 FCI, FLAG, 0 HR. RESET DELAY, (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. 0 Hour reset dealy. Customer Specific Modification 45046.) ABB
7TAA207410R0013 FCI, ADAPTIVE, 300A DI/DT, (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. 300 Amp DI/DT. Customer Specific Modification 45002) ABB
7TAA207410R0012 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 40531.) ABB
7TAA207410R0011 FAULT INDICATOR, 1HR RESET (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. 1 Hour reset. Customer Specific Modification 40427.) ABB
7TAA207410R0010 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 40413.) ABB
7TAA207410R0009 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 40328.) ABB
7TAA207410R0008 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 40301.) ABB
7TAA207410R0007 FCI, ADAPTIVE TRIP, RESET (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 40112.) ABB
7TAA207410R0006 FCI, FLAG, BRACKET, TIE-WRAP, (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Bracket, Tie-Wrap. Customer Specific Modification 39674.) ABB
7TAA207410R0005 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 39548.) ABB
7TAA207410R0004 F.I. ADAPTIVE TRIP, 4HR TIME (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. 4 Hour Time. Customer Specific Modification 39547.) ABB
7TAA207410R0003 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 39476.) ABB
7TAA207410R0002 FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 39040.) ABB