| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA207410R0091
|
FP SERIES 1547 ADAPTIVE TRIP FCI (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI 10 foot Remote Fiber Optic cable display. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option M - 4 hour reset with manual reset. Sensor Mounting option T - Integral Hotstick. Reset Current option L - 1.5 Amp (1-5/8 inch sensor with U-Lamination). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard)
|
ABB
|
|
7TAA207410R0090
|
FCI,ADAPTIVE TRIP,HOTSTICK MOUNTED (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI 10 foot Remote Fiber Optic cable display. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option E - 4 hour reset with current and manual reset override. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard)
|
ABB
|
|
7TAA207410R0089
|
FCI, REMOTE OPTIC, 10', 4HR RESET (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI 10 foot Remote Fiber Optic cable display. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option C - 4 hour reset with current override. Sensor Mounting option T - Integral Hotstick. Reset Current option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0088
|
FAULTED CIRCUIT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Indicator Mounting Option M - Tie-Wrap Mount. Reset Delay Option M - 4 hour reset with manual reset. Sensor Mounting option G - Integral Tie-Wrap. Reset Current option L - 1.5 Amp (2-3/16 inch sensor with U-Lamintaion). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0087
|
FCI, LED, SURFACE MTG, 4 HR RESET (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Indicator Mounting Option M - Tie-Wrap Mount. Reset Delay Option C - 4 hour reset with current override. Sensor Mounting option G - Integral Tie-Wrap. Reset Current option L - 1.5 Amp (2-3/16 inch sensor with U-Lamintaion). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0086
|
ADAPTIVE TRIP FCI (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator LED Type. LED or Remote Fiber Optic Reset Delay. Hotstick Mount with Clamp. 4 hr reset time delay after power restoration.)
|
ABB
|
|
7TAA207410R0085
|
FP SERIES 1547 ADAPTIVE TRIP FCI (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator LED Type. LED or Remote Fiber Optic Reset Delay. Hotstick Mount with Clamp. 4 hr reset time delay after power restoration.)
|
ABB
|
|
7TAA207410R0084
|
FP SERIES 1547 ADAPTIVE TRIP FCI (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option N - 4 hour reset with manual trip and manual reset. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0083
|
FCI, REMOTE OPTIC, 10', 4HR RESET (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option E - 4 hour reset with current and manual reset override. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0082
|
FAULTED CIRCUIT INDICATOR (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator LED Type. LED or Remote Fiber Optic Reset Delay. Hotstick Mount with Clamp. 4 hr with current and manual reset override.)
|
ABB
|
|
7TAA207410R0081
|
FAULT CIRCUIT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option C - 4 hour reset with current override. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0080
|
FP SERIES 1547 ADAPTIVE TRIP FRIC (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Customer Specific Modifications CS1682.)
|
ABB
|
|
7TAA207410R0079
|
FP SERIES 1547 ADAPTIVE TRIP FCI (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI LED type. Customer Specific Modifications 39514.)
|
ABB
|
|
7TAA207410R0078
|
FCI,ADAPTIVE TRIP,FLAG TYPE (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option P - Window/Fluch Mount. Reset Delay Option W - 4 hour reset time delay after power restoration. Sensor Mounting Option S - Remote Tie-Wrap. Reset Current Option L - 1.5 Amp (2-3/16 inch sensor with U-Lamination). SCADA Output option N - No SCADA. 10 foot Lead between Sensor and Display. Close Proximity - Raised zero reference to 7A.)
|
ABB
|
|
7TAA207410R0077
|
FCI, ADAPTIVE, FLAG, FLUSH, 4 HR RS (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option P - Window/Fluch Mount. Reset Delay Option W - 4 hour reset time delay after power restoration. Sensor Mounting Option H - Remote Hotstick. Reset Current Option M - 1.0 Amp (1-5/8 inch sensor with U-Lamination). SCADA Output option B - N.C. - 10 foot lead. 10 foot Lead between Sensor and Display. Close Proximity - Standard.)
|
ABB
|
|
7TAA207410R0076
|
FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option M - Tie-Wrap Mount. Reset Delay Option Z - 60 second reset time delay after power restoration. Sensor Mounting Option G - Integral Tie-Wrap. Reset Current Option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.)
|
ABB
|
|
7TAA207410R0075
|
FAULTED CIRCUIT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option M - Tie-Wrap Mount. Reset Delay Option W - 4 Hour reset time delay after power restoration. Sensor Mounting Option G - Integral Tie-Wrap. Reset Current Option L - 1.5 Amp (2-3/16 inch sensor with U-Lamination). SCADA Output option N - No SCADA. No Lead between Sensor and Display - attached indicatior sensor units. Close Proximity - Standard.)
|
ABB
|
|
7TAA207410R0074
|
ADAPTIVE TRIP FCI,FLAG TYPE (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Indicator Mounting Option B - Bracket/Surface Mount. Reset Delay Option Z - 60 second reset time delay after power restoration. Sensor Mounting option S - Remote Tie-Wrap. Reset Current option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option B - N.C. 15 foot Lead. Close Proximity option N - Standard.)
|
ABB
|
|
7TAA207410R0073
|
FAULTED CIRCUIT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 45158.)
|
ABB
|
|
7TAA207410R0072
|
FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI Flag type. Customer Specific Modification 38649.)
|
ABB
|
|
7TAA207410R0071
|
FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option Z - 60 second reset time delay only. Sensor Mounting option T - Integral Hotstick. Reset Current option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard. Transmitter Phase Encoding option C - Phase C.)
|
ABB
|
|
7TAA207410R0070
|
FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option Z - 60 second reset time delay only. Sensor Mounting option T - Integral Hotstick. Reset Current option B - 2.0 Amp (1-5/9 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard. Transmitter Phase Encoding option B - Phase B.)
|
ABB
|
|
7TAA207410R0069
|
FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option Z - 60 second reset time delay only. Sensor Mounting option T - Integral Hotstick. Reset Current option B - 2.0 Amp (1-5/9 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard. Transmitter Phase Encoding option A - Phase A.)
|
ABB
|
|
7TAA207410R0068
|
4 HR W/CUR RFCI LED,2-3/16 (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option J - 4 hour reset with current override. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard. Transmitter Phase Encoding option C - Phase C.)
|
ABB
|
|
7TAA207410R0067
|
4 HR W/CUR RFCI LED,2-3/16 (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option J - 4 hour reset with current override. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard. Transmitter Phase Encoding option B - Phase B.)
|
ABB
|
|
7TAA207410R0066
|
4 HR W/CUR RFCI LED,2-3/16 (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option J - 4 hour reset with current override. Sensor Mounting option T - Integral Hotstick. Reset Current option D - 3.0 Amp (2-3/16 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard. Transmitter Phase Encoding option A - Phase A.)
|
ABB
|
|
7TAA207410R0065
|
FCI,RADIO,LED,MANUAL TRIP & (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Integral Radio Transmitter LED Type. Radio, LED, Manual Trip. Customer Specific Modifications 39597.)
|
ABB
|
|
7TAA207410R0064
|
FAULT INDICATOR (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator. 10 fit. Remote Fiber Optic cable display (other lengths available). LED or Remote Fiber Optic Reset Delay. Tie-Wrap Mount. 4-hr reset time delay with current and manual reset override.)
|
ABB
|
|
7TAA207410R0063
|
FAULT INDICATOR (Series 1547 Adaptive Trip Underground Faulted Circuit Indicator, Standard FCI 10 foot Remote Fiber Optic cable display. Indicator Mounting Option H - Hotstick Mount with Clamp. Reset Delay Option T - 4 hour reset time dealy with current override, manual trip and manual reset override. Sensor Mounting option T - Integral Hotstick. Reset Current option B - 2.0 Amp (1-5/8 inch sensor). SCADA Output option N - No SCADA. Lead Length option N - None - attached indicator sensor units. Close Proximity option N - Standard)
|
ABB
|
|
7TAA207410R0062
|
FCI, 1.0 AMP RESET, 4HR RESET (Series 1547 Adaptive Trip Faulted Circuit Indicator. Standard Faulted Circuit Indicator LED Type. LED or Remote Fiber Optic Reset Delay. Window/Flush Mount. 4-hr reset time delay with current override. manual trip and manual reset override.)
|
ABB
|