7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA207420R0104
|
FAULT INDICATOR (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.)
|
ABB
|
|
7TAA207420R0103
|
FCI,1 PHASE W/INTEGRAL RADIO/LED (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 60-sec delay after fault occurrence. 1 Phase, Trasmitter Phase Encoding - Option C - Phase C)
|
ABB
|
|
7TAA207420R0102
|
FCI,1 PHASE,INTEGRAL RADIO/LED DISP (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 60-sec delay after fault occurrence. 1 Phase)
|
ABB
|
|
7TAA207420R0101
|
FCI,1PHASE,INTEGRAL RADIO/LED DISP (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 60-sec delay after fault occurrence.)
|
ABB
|
|
7TAA207420R0100
|
FCI,REMOTE LED,50A TRIP, 1.2A RESET (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Remote, 6 foot fiber optic LED display (requires M mounting). M Mounting Option - Tie-wrap mounting (attached indicator/sensors). Trip Settings - 50 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option E - 4 hour reset time delay after fault occurrence with manual rest override. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option G - Sensor attached to indicator, Tie-Wrap Mount. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation. Trasmitter Phase Encoding - Option B - Phase B)
|
ABB
|
|
7TAA207420R0099
|
1514,CURRENT RESET FCI,LED DISPLAY (Series 1514 Current Reset Faulted Circuit Indicator with LED display and Inrush Restraint. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. 4 hr reset time delay after fault occurrence with current reset override upon energization of line. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp.)
|
ABB
|
|
7TAA207420R0098
|
CURRENT RESET FCI,1PH,LED DISPLAY (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -1200 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option M - 4 hour reset time delay after fault occurrence with manual reset override. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option B - Phase B)
|
ABB
|
|
7TAA207420R0097
|
CURRENT RESET FCI,1PH,FLAG DISPLAY (Smartnet Directional Network Faulted Circuit Indicator, Flag Display, Window/flush mounting (remote from sensor), Current Reset FCI, One Phase, Flag Display, 800 Amps, Inrush restraint, 60 second reset time delay after restoration of power. 3 Amp Minimum Reset Current Level, 10 Foot lead length between Sensor and Display. Hotstick clamp attached to sensor (1-5/8 inch and 2-3/16 inch cable only) Maximum cable Diameter is 2-3/16 inch.)
|
ABB
|
|
7TAA207420R0096
|
FCI, 3 PH, FLAG 800A TRIP 1.5A (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0095
|
FAULT INDICATOR (Series 1515 Current Reset Faulted Circuit Indicator with Flag Display. Window/Flush mounting. 800A Fixed Trip Setting. Inrush restraint, no automatic reset, manual reset only. Standard Trip Curve, 10 to 30 sec. delay after restoration of power. 3 Phase)
|
ABB
|
|
7TAA207420R0094
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0093
|
FCI,FLAG,600A TRIP, 60 DELAY (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option H - Hotstick Clamp attached to sensor (1-5/8 inch and 2-3/16 inch cable diameter only). Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0092
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option W - Inrush restraint, 4 hour reset time delay after restoration of power. Minimum Reset Current Level is 1.5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0091
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0090
|
FCI, INRUSH, 0 HR DELAY, (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 400 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option D - 2-3/16 inches.)
|
ABB
|
|
7TAA207420R0089
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 400 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option W - Inrush restraint, 4 hour reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0088
|
FAULT INDICATOR,300AMP,2 HR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). 300 Amp, 2 Hour Delay. Customer Specific Modication 39618.)
|
ABB
|
|
7TAA207420R0087
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Customer Specific Modication 38508.)
|
ABB
|
|
7TAA207420R0086
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Customer Specific Modication 39152.)
|
ABB
|
|
7TAA207420R0085
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 200 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0084
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 1000 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0083
|
FCI, FLAG, 1000 AMP, 12 FT, (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 1000 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option xx - 12. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0082
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, M Mounting Option - Tie-wrap mounting (attached indicator/sensors). Customer Specific Modication 29807.)
|
ABB
|
|
7TAA207420R0081
|
FCI,800 AMP TRIP,1.5 AMP RESET (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0080
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 5. Lead Length between Sensor and Display - Option - 30 foot. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0079
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0078
|
FCI,800A TRIP,STANDARD TRIP (Series 1515 Current Reset Faulted Circuit Indicator with Flag Display and Bracket/surface mounting. 800A Fixed Trip Setting. Inrush restraint, no automatic reset, manual reset only. Standard Trip Curve, 10 to 30 sec. delay after restoration of power. 6 foot lead. 3 Phase)
|
ABB
|
|
7TAA207420R0077
|
FAULT INDICATOR (Series 1515 Current Reset Faulted Circuit Indicator with Flag Display and Bracket/surface mounting. 800A Fixed Trip Setting. Inrush restraint, no automatic reset, manual reset only. Standard Trip Curve, 10 to 30 sec. delay after restoration of power. 3 Phase)
|
ABB
|
|
7TAA207420R0076
|
FCI, 600 AMP TRIP, 3AMP RESET, (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0075
|
FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 5. Lead Length between Sensor and Display - Option - 30 foot. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|