7TAA2
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
7TAA207420R0134
|
FCI,LED,PANEL/FLUSH MTD,4HR & CURRE (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 300 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option C - 4 hour reset time delay after fault occurrence with current rest override upon energization of line. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0133
|
1515, CURRENT RESET FCI,3 PHASE (Series 1515 Current Reset Faulted Circuit Indicator with LED Display and Inrush Restraint and Manual Reset Override. Window/Flush mounting. 200A Fixed Trip Setting. 4 hr reset time delay after fault occurrence. 3 Phase.)
|
ABB
|
|
7TAA207420R0132
|
3-PHASE FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 800 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option N - 4 hour reset time delay after fault occurrence with manual trip and manual reset override. Minimum Reset Current Level is 1.5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0131
|
FP CURRENT RESET 3 PH FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 400 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option W - 4 hour reset time delay after fault occurrence. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0130
|
FP CURRENT-RESET 3-PHASE FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0129
|
FP CURRENT-RESET 3-PHASE FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 300 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0128
|
FP THREE PH FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 5. Lead Length between Sensor and Display - Option xx - 20 foot. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0127
|
FP SERIES CURRENT RESET FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0126
|
1515 CURRENT RESET FCI,3 PHASE (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 300 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option xx - 20 foot. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0125
|
FCI,CURRENT RESET,3-PH,SCADA (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 200 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option N - Inrush restraint, No automatic reset, manual reset only. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0124
|
FCI,600A TRIP,3A RESET,FLAG DISPLAY (Series 1514 Current Reset Faulted Circuit Indicator with Flag Display and Manual Reset Override. Window/Flush mounting. 600A Fixed Trip Setting. Standard Trip Curve, 10 to 30 sec. delay after restoration of power.)
|
ABB
|
|
7TAA207420R0123
|
FCI,FLAG,FLUSH,100A,STD,3A RS, 10FT (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings -100 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0122
|
CURRENT-RESET FCI, 400A TRIP (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, M Mounting Option - Tie-wrap mounting (attached indicator/sensors), Trip Settings -400 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option G - Sensor attached to indicator, Tie-Wrap Mount. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0121
|
FCI, CURRENT-RESET, FLAG DISPLAY (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option P - Inrush restraint, 24 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Customer specific modification 1568.)
|
ABB
|
|
7TAA207420R0120
|
FP SINGLE PHASE CURRENT RESET FCI (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0119
|
FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option P - Inrush restraint, 24 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.)
|
ABB
|
|
7TAA207420R0118
|
FCI,CURRENT RESET,FLAG DISPLAY (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). 200 Amp Trip, Manual Reset only. Carries current. Customer Specific Modication 38721.)
|
ABB
|
|
7TAA207420R0117
|
1514 FCI W/ FLAG, 200A TRIP (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -200 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option N - Inrush restraint, No automatic reset, manual reset only. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0116
|
UNDERGROUND/PADMOUNT FCI (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -100 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option W - Inrush restraint, 4 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0115
|
1PH, CURRENT RESET FCI (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option H - Hotstick Clamp attached to sensor (1-5/8 inch and 2-3/16 inch cable diameter only). Maximum Cable Diameter - Option D - 2-3/16 inches.)
|
ABB
|
|
7TAA207420R0114
|
FCI CURRENT-RESET 1PH 400A TRIP SET (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings -400 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0113
|
FCI,1 PH,FLAG,2 SENSORS, INRUSH (Series 1514 Underground Faulted Circuit Indicator - Single Phase, Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Two sensor input for dual connector applications, 800 Amp trip, Inrush restraint, 3 Amp Reset, 10 foot indicator, Monitors current.)
|
ABB
|
|
7TAA207420R0112
|
CURRENT RESET FCI,FLAG DISPLAY,1 PH (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings -300 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option N - Inrush restraint, No automatic reset, manual reset only. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option B - 1-5/8 inches.)
|
ABB
|
|
7TAA207420R0111
|
FCI, FLAG SURFACE MTG 200A TRIP (Series 1514 Current Reset Faulted Circuit Indicator with Flag display and Manual Set Override. Bracket/surface mounting. 200A Fixed Trip setting.)
|
ABB
|
|
7TAA207420R0110
|
FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag display with monentary (N.O.) SCADA output. H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option P - Inrush restraint, 24 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches.)
|
ABB
|
|
7TAA207420R0109
|
FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Integral Radio/LED display (requires M mounting). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Radio Indication, Inrush Restraint, Manual Trip and Manual Reset Override - Option J - 4 hour reset time delay after fault occurrence with current reset override upon energization of line. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option C - Phase C)
|
ABB
|
|
7TAA207420R0108
|
FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Integral Radio/LED display (requires M mounting). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Radio Indication, Inrush Restraint, Manual Trip and Manual Reset Override - Option J - 4 hour reset time delay after fault occurrence with current reset override upon energization of line. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option B - Phase B)
|
ABB
|
|
7TAA207420R0107
|
FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Integral Radio/LED display (requires M mounting). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Radio Indication, Inrush Restraint, Manual Trip and Manual Reset Override - Option J - 4 hour reset time delay after fault occurrence with current reset override upon energization of line. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option A - Phase A)
|
ABB
|
|
7TAA207420R0106
|
FAULT INDICATORS (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.)
|
ABB
|
|
7TAA207420R0105
|
FAULT INDICATORS (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.)
|
ABB
|