7TAA207420R0134 FCI,LED,PANEL/FLUSH MTD,4HR & CURRE (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 300 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option C - 4 hour reset time delay after fault occurrence with current rest override upon energization of line. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0133 1515, CURRENT RESET FCI,3 PHASE (Series 1515 Current Reset Faulted Circuit Indicator with LED Display and Inrush Restraint and Manual Reset Override. Window/Flush mounting. 200A Fixed Trip Setting. 4 hr reset time delay after fault occurrence. 3 Phase.) ABB
7TAA207420R0132 3-PHASE FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 800 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option N - 4 hour reset time delay after fault occurrence with manual trip and manual reset override. Minimum Reset Current Level is 1.5. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0131 FP CURRENT RESET 3 PH FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , LED Display (non-replaceable battery). B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 400 Amps, Inrush Restraint/Reset Delay Options - LED Display, Inrush Restraint - Option W - 4 hour reset time delay after fault occurrence. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0130 FP CURRENT-RESET 3-PHASE FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0129 FP CURRENT-RESET 3-PHASE FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings - 300 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0128 FP THREE PH FAULT INDICATOR (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 5. Lead Length between Sensor and Display - Option xx - 20 foot. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0127 FP SERIES CURRENT RESET FCI (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option N - 2-5/16 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0126 1515 CURRENT RESET FCI,3 PHASE (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 300 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option xx - 20 foot. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0125 FCI,CURRENT RESET,3-PH,SCADA (Series 1515 Underground Faulted Circuit Indicator - Three Phase (three sensors, one indicator) Unit requires current in all phases to reset. Current Reset Faulted Circuit Indicator. , Flag Display and single (N.O.) latching SCADA output contact, SCADA Contacts 3.0 Amps at 124/250 VAC, 1/10 hp at 250 VAC. B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings - 200 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option N - Inrush restraint, No automatic reset, manual reset only. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option B - 1-5/8 inches.) ABB
7TAA207420R0124 FCI,600A TRIP,3A RESET,FLAG DISPLAY (Series 1514 Current Reset Faulted Circuit Indicator with Flag Display and Manual Reset Override. Window/Flush mounting. 600A Fixed Trip Setting. Standard Trip Curve, 10 to 30 sec. delay after restoration of power.) ABB
7TAA207420R0123 FCI,FLAG,FLUSH,100A,STD,3A RS, 10FT (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, P Mounting Option - Window/flush mounting (remote from sensor). Trip Settings -100 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0122 CURRENT-RESET FCI, 400A TRIP (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, M Mounting Option - Tie-wrap mounting (attached indicator/sensors), Trip Settings -400 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 1.2. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option G - Sensor attached to indicator, Tie-Wrap Mount. Maximum Cable Diameter - Option M - 1-5/8 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0121 FCI, CURRENT-RESET, FLAG DISPLAY (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option P - Inrush restraint, 24 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Customer specific modification 1568.) ABB
7TAA207420R0120 FP SINGLE PHASE CURRENT RESET FCI (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option B - 1-5/8 inches.) ABB
7TAA207420R0119 FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -600 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option P - Inrush restraint, 24 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option L - 2-3/16 inches and has snap-on U lamination for circuit isolation.) ABB
7TAA207420R0118 FCI,CURRENT RESET,FLAG DISPLAY (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). 200 Amp Trip, Manual Reset only. Carries current. Customer Specific Modication 38721.) ABB
7TAA207420R0117 1514 FCI W/ FLAG, 200A TRIP (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -200 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option N - Inrush restraint, No automatic reset, manual reset only. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option B - 1-5/8 inches.) ABB
7TAA207420R0116 UNDERGROUND/PADMOUNT FCI (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -100 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option W - Inrush restraint, 4 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option B - 1-5/8 inches.) ABB
7TAA207420R0115 1PH, CURRENT RESET FCI (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option A - Standard Trip Curve, 10-30 second delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option H - Hotstick Clamp attached to sensor (1-5/8 inch and 2-3/16 inch cable diameter only). Maximum Cable Diameter - Option D - 2-3/16 inches.) ABB
7TAA207420R0114 FCI CURRENT-RESET 1PH 400A TRIP SET (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings -400 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option Z - Inrush restraint, 60 second reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option B - 1-5/8 inches.) ABB
7TAA207420R0113 FCI,1 PH,FLAG,2 SENSORS, INRUSH (Series 1514 Underground Faulted Circuit Indicator - Single Phase, Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Two sensor input for dual connector applications, 800 Amp trip, Inrush restraint, 3 Amp Reset, 10 foot indicator, Monitors current.) ABB
7TAA207420R0112 CURRENT RESET FCI,FLAG DISPLAY,1 PH (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag Display, B Mounting Option - Bracket/surface mounting (remote from sensor). Trip Settings -300 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option N - Inrush restraint, No automatic reset, manual reset only. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option 10 - 10 foot standard. Sensor Termination - Option S - Terminates with remote lead connected to sensor. Maximum Cable Diameter - Option B - 1-5/8 inches.) ABB
7TAA207420R0111 FCI, FLAG SURFACE MTG 200A TRIP (Series 1514 Current Reset Faulted Circuit Indicator with Flag display and Manual Set Override. Bracket/surface mounting. 200A Fixed Trip setting.) ABB
7TAA207420R0110 FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Flag display with monentary (N.O.) SCADA output. H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Flag Display, Manual Reset Override - Option P - Inrush restraint, 24 hour reset time delay after restoration of power. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches.) ABB
7TAA207420R0109 FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Integral Radio/LED display (requires M mounting). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Radio Indication, Inrush Restraint, Manual Trip and Manual Reset Override - Option J - 4 hour reset time delay after fault occurrence with current reset override upon energization of line. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option C - Phase C) ABB
7TAA207420R0108 FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Integral Radio/LED display (requires M mounting). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Radio Indication, Inrush Restraint, Manual Trip and Manual Reset Override - Option J - 4 hour reset time delay after fault occurrence with current reset override upon energization of line. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option B - Phase B) ABB
7TAA207420R0107 FAULTED CIRCUIT INDICATOR (Series 1514 Underground Faulted Circuit Indicator - Single Phase (one sensor, one indicator), Current Reset Faulted Circuit Indicator. , Integral Radio/LED display (requires M mounting). H Mounting Option - Hotstick mounting (attached indicator/sensor) (B and D sensors only, one phase only). Trip Settings -800 Amps, Inrush Restraint/Reset Delay Options - Radio Indication, Inrush Restraint, Manual Trip and Manual Reset Override - Option J - 4 hour reset time delay after fault occurrence with current reset override upon energization of line. Minimum Reset Current Level is 3. Lead Length between Sensor and Display - Option N - None - Attached indicator sensor units, G or T sensor termination. Sensor Termination - Option T - Sensor and indicator attached to Hotstick clamp. Maximum Cable Diameter - Option K - 2-5/16 inches. Trasmitter Phase Encoding - Option A - Phase A) ABB
7TAA207420R0106 FAULT INDICATORS (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.) ABB
7TAA207420R0105 FAULT INDICATORS (Series 1514 Current Reset Faulted Circuit Indicator with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.) ABB