7TAA2

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
7TAA207880R0007 FAULTED CIRCUIT INDICATOR (Series 1514 Faulted Circuit Indicator, Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modification 40324.) ABB
7TAA207880R0006 FAULTED CIRCUIT INDICATOR (Series 1548 Overhead Faulted Circuit Indicators. Standard Offering, reclose dead time of 150 msec. (loss of current greater than 150 msec.), 3 Amp minimum load current required for reset. Customer Specific Modication 45019.) ABB
7TAA207450R0005 NEUTRAL CURRENT SENSOR W/ CONNECTOR (Series 1580 Fixed Capacitor Bank Neutral Sensing Indicator with contact output) ABB
7TAA207450R0004 FCI,NEUTRAL CURRENT,CONTACT OUTPUT (Series 1580 Fixed Capacitor Bank Neutral Sensing Indicator with contact output) ABB
7TAA207450R0000 CONTROLLER & TRANSMITTER ABB
7TAA207440R0045 1PH FCI 400A TRIP, TIME RESET (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay.Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point - 400 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0044 FCI 1PH 200A TRIP URD TIME RESET (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay.Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point - 200 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option F - Remote LED, removalbe fiber optic cable. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0043 FCI,AUTOMATIC TIME RESET 600A TRIP (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point - 600 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. Display Option T - Integral LED (always selected with code H under Indicator/Battery Options. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0042 FCI 3PH 800A TRIP REMOVABLE F/O CAB (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point of 800 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option F - Remote LED, removalbe fiber optic cable. Cable Clamp Size - Large - 2.36 inch to 3.55 inch cable diameter. Removable F/O cable.) ABB
7TAA207440R0041 FP AUTOMATIC TIME RESET FCI (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point of 800 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option E - Remote LED, fiber optic cable. Cable Clamp Size - Medium - 1.58 inch to 2.36 inch cable diameter.) ABB
7TAA207440R0040 FAULT INDICATOR 3PH AUTO 4-HR RESET (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point of 1000 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Medium - 1.58 inch to 2.36 inch cable diameter.) ABB
7TAA207440R0038 FAULTED CIRCUIT INDICATOR (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 800 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. Customer Specific Modification 39398.) ABB
7TAA207440R0037 3 PHASE, AUTOMATIC TIME RESET FCI (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 800 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Medium - 1.58 inch to 2.36 inch cable diameter.) ABB
7TAA207440R0036 FCI,3PH,HOT STICK, REMOTE LED 10' (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 600 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Medium - 1.58 inch to 2.36 inch cable diameter.) ABB
7TAA207440R0035 FCI, 3 PHASE, TIME RESET, 450A TRIP (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 450 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. Customer Specific Modification 39397.) ABB
7TAA207440R0034 THREE PH,AUTOMATIC TIME RESETFCI (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 450 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0033 FAULTED CIRCUIT INDICATOR (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 200 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. Customer Specific Modification 39400.) ABB
7TAA207440R0032 AUTOMATIC TIME RESET FCI,3 PHASE (Series 1543 Automatic Time Reset Faulted Circuit Indicator. Automatic Time Reset Faulted Circuit Indicator. Inrush trip delay, LED, non-replaceable battery, hotstick mounted. Remote LED display. 100 Amp. 3 Phase) ABB
7TAA207440R0031 1543 FCI (Series 1543 - Underground Faulted Circuit Indicator - Three Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 1000 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Medium - 1.58 inch to 2.36 inch cable diameter.) ABB
7TAA207440R0030 FAULTED CIRCUIT INDICATOR (Series 1542 - Underground Faulted Circuit Indicator - Two Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point of 200 Amps. Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. Customer Specific Modification 39399.) ABB
7TAA207440R0029 SINGLE PH FCI, 80A PU, REMOTE LED (Series 1541 Automatic Time Reset Faulted Circuit Indicator. Inrush trip delay, LED, non-replaceable battery, hotstick mounted. Remote LED display. Single Phase. 80 Amp.) ABB
7TAA207440R0028 1PH,AUTOMATIC,TIME RESET FCI (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay.Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point - 300 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0027 UNDERGROUND FCI (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay.Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point - 200 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0026 FCI,1P,INRUSH,10FT LED,100A,2HR RS (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay.Indication/Battery Option R - LED, replaceable battery, hotstick mounted. Trip Point - 100 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0025 FCI,3PH,800A TRIP,4HR RS, 20' LED (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point - 800 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 20 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0024 FCI,3PH,800A TRIP,4HR RS, 10' LED (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point - 800 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Medium - 1.58 inch to 2.36 inch cable diameter.) ABB
7TAA207440R0023 FCI,AUTOMATIC TIME RESET FCI (Series 1541 Automatic Time Reset Faulted Circuit Indicator. Inrush trip delay, LED, non-replaceable battery, hotstick mounted. Integral LED display. Single Phase. 600 Amp) ABB
7TAA207440R0022 1541 AUTOMATIC TIME RESET FCI (Series 1541 Automatic Time Reset Faulted Circuit Indicator. Inrush trip delay, LED, non-replaceable battery, hotstick mounted. Remote LED display. Single Phase. 400 Amp) ABB
7TAA207440R0021 1PH,AUTO TIME RESET FCI (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point - 400 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. 10 foot Remote LED Cable. Display Option R - Remote LED. Cable Clamp Size - Small - .63 inch to 1.58 inch cable diameter.) ABB
7TAA207440R0020 FAULT INDICATOR (Series 1541 - Underground Faulted Circuit Indicator - Single Phase. Inrush Restraint option F - Inrush Trip Delay. Indication/Battery Option H - LED, non-replaceable battery, hotstick mounted. Trip Point - 200 Amps, Reset Time Delay after Fault Occurrence option A - 4 hour automatic reset time delay. Customer Specific Modification - 39144.) ABB