7TAA266250R0005
|
AL BOLTED SUBSTATION GROUND STUD (Aluminum Bolted Substation Ground Stud - - Ground Stud to Pipe - 1-1/2 inch Pipe to 3, with Stainless Steel Hardware)
|
ABB
|
|
7TAA266250R0004
|
AL BOLTED SUBSTATION GROUND STUD (Aluminum Bolted Substation Ground Stud - - Ground Stud to Pipe - 1-1/2 inch Pipe to 3)
|
ABB
|
|
7TAA266250R0003
|
AL BOLTED SUBSTATION GROUND STUD (Aluminum Bolted Substation Ground Stud - - Ground Stud to Pipe - 1-1/4 inch Pipe to 3)
|
ABB
|
|
7TAA266250R0002
|
AL BOLTED SUBSTATION GROUND STUD (Aluminum Bolted Substation Ground Stud - - Ground Stud to Pipe - 1 inch Pipe to)
|
ABB
|
|
7TAA266250R0000
|
ABGS-100 X (Aluminum Bolted Ground Stud, 250-1000 AAC)
|
ABB
|
|
7TAA266240R0469
|
ALUMINUM BOLTED TERMINAL (Aluminum Bolted Two Conductor Terminal for Two Cables to Flat, 2 Cap Design, Conductor 1250-1600 Aluminum, 1113-1272 ACSR, 4 Hole, 4 x 4 inch Pad, Cable Spacing 13 inches, 90 Degree Bend)
|
ABB
|
|
7TAA266240R0468
|
ALUMINUM BOLTED TERMINAL TWO CABLES (Aluminum Bolted Two Conductor Terminal for Two Cables to Flat, 2 Cap Design, Conductor 1250-1600 Aluminum, 4 Hole, 4 x 4 inch Pad, Cable Spacing 13 inches)
|
ABB
|
|
7TAA266240R0467
|
ALUMINUM BOLTED TERMINAL (Aluminum Bolted Two Conductor Terminal for Two Cables to Flat, 2 Cap Design, Conductor 1500-2000 AAC, 1272-1590 ACSR, 4 Hole, 4 x 4 inch Pad)
|
ABB
|
|
7TAA266240R0465
|
ALUM BOLTED TERMINAL CABLES TO 4HNP (Aluminum Bolted Terminal, 2 Cable to Flat, 2 Cap Design, 1510.5-1600 AAC to 4 X 4 inch 4-Hole Pad. For BC Hydro)
|
ABB
|
|
7TAA266240R0464
|
ALUM BOLTED PIPE TERMINAL AT 45 (Bolted Aluminum Connector, Type ABN-45, Bolted Terminal, Pipe to Flat at 45 Degrees. 3 Inch 4-Hole NEMA Flat. SPS - Standard Pipe Size is 2. 3 inch X 5/8 inch thick, Amps is 1155.)
|
ABB
|
|
7TAA266240R0463
|
ALUM BOLTED TERMINAL AT 45 DEGREES (Bolted Aluminal Terminal, Pipe to Flat at 45 Degrees, 2 Hole NEMA Pad, SPS - Standard Pipe Size 3/4 inch, 3 inch X 1/2 inch Thick.)
|
ABB
|
|
7TAA266240R0462
|
ALUM BOLTED TERMINAL (Aluminum Bolted Substation Terminal - 2 Cables to Pad - Straight - Side-formed Pad - Dual Taps, Side-by-Side, Two Caps - 230kV Maximum - 800-3000 AAC 715.5-2500 ACSR to 4X4 inch, 4-hole Pad)
|
ABB
|
|
7TAA266240R0461
|
BOLTED TERMINAL FOR 1 INCH PIPE (Bolted Aluminum Connector, Type ABN, Bolted Terminal, Pipe to Flat. 4 Inch 4-Hole NEMA Flat. SPS is 1. 7-7/8 inch X 3 inch X 1/2 inch thick, Amps is 1155. E40M-90 is for special pad configuration.)
|
ABB
|
|
7TAA266240R0455
|
ALUMINUM TERMINAL (Aluminum Bolted Substation Terminal (60 Degree - Stainless Steel Hardware) - Pipe to Pad - 4 inch Pipe to 4 X 4 inch 4-hole Pad at 60 Degrees)
|
ABB
|
|
7TAA266240R0454
|
ALUMINUM TERMINAL (Bolted Aluminum Connector, Type A7MM1, Bolted Terminal, Two Cables to Flat, One-Cap Design. 4 INCH 4-Hole NEMA Flat. Cable Size AAC 1100-2500, Cable Size ACSR 1133-2300, Cable Diameter 1.209-1.823 inch, 8-7/8 inch X 4 inch X 7/8 inch thick. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides. SS is for Substitute with Stainless Steel Hardware.)
|
ABB
|
|
7TAA266240R0453
|
ALUMINUM TERMINAL, 90 DEG (Bolted Aluminum Connector, Type A7MM1-90, Bolted Terminal, Two Cables to Flat at 90 Degree, One-Cap Design. Cable Size AAC 1100-2500, Cable Size ACSR 1133-2300, Cable Diameter 1.209-1.823 inch, 4 inch X 7/8 inch. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides. SS is for Substitute with Stainless Steel Hardware.)
|
ABB
|
|
7TAA266240R0452
|
EXPANSION TERMINAL (Bolted Aluminum Connector, Type ABEPC - Bolted Expansion Terminal, Pipe to Flat, Center Formed. 4 inch 4-Hole NEMA Flat. Schedule 80 Pipe, SPS 4, 18 inch X 1 inch thick, AMPS 2000. SS is for Substitute with Stainless Steel Hardware.)
|
ABB
|
|
7TAA266240R0451
|
ALUMINUM TEE (Bolted Aluminum Connector, Type ABNT, Bolted Tee, Pipe to Flat. 4 Inch 4-Hole NEMA Flat. SPS is 4. 11-1/2 inch X 4 inch X 3/4 inch thick, Amps is 2000. SS is for Substitute with Stainless Steel Hardware. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides.)
|
ABB
|
|
7TAA266240R0450
|
BOLTED TERMINAL (Bolted Aluminum Connector, Type A7MM1-45, Bolted Terminal, Two Cables to Flat at 45 Degree, One-Cap Design. Cable Size AAC 556-1500, Cable Size ACSR 636-1272, Cable Diameter .856-1.412 inch, 3-5/8 inch X 7/8 inch. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides. E4560M is for special Pad Configuration.)
|
ABB
|
|
7TAA266240R0449
|
BOLTED TERMINAL (Bolted Aluminum Connector, Type ABNC, Bolted Terminal, Pipe to Flat, Center Formed. 4 Inch 4-Hole NEMA Flat. SPS is 5. 11-3/8 inch X 6-1/2 inch X 1 inch thick, Amps is 3080. Four 18MM Hole Pad.)
|
ABB
|
|
7TAA266240R0447
|
ALUM BOLTED TERMINAL CABLE TO 2HNP (Bolted Aluminum Connector, Type A7M - Bolted Terminal, Cable to Flat. 2-Hole NEMA Flat. Cable Size AAC 556-1500, Cable Size ACSR 636-1272, Cable Diameter .856-1.412 inch, 7-5/8 X 3-5/8 inch. 5/8 inch thick. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides. SSB is for substitute with stainless steel Bolt, Lock washer and Silicon Bronze Nut.)
|
ABB
|
|
7TAA266240R0446
|
ALUM CABLE TERMINAL TIN PLATED (Bolted Aluminum Connector, Type A6MT - Bolted Tee, Pipe to Cable. RUN SPS 1-1/2, Cable Size RUN ACC 250-1000, Cable Size RUN ACSR 300-795, Cable Diameter Min-Max .567-1.150, Dimensions 7-9/16 X 2-15/16 inch, Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. R is for Tin Plate.)
|
ABB
|
|
7TAA266240R0445
|
ALUMINUM BOLTED TERMINAL 2HNP@45 (Bolted Aluminum Connector, Type ABN-45, Bolted Terminal, Pipe to Flat at 45 Degrees. 3 Inch 4-Hole NEMA Flat. SPS is 3-1/2. 4-/4 inch X 7/8 inch thick, Amps is 600.)
|
ABB
|
|
7TAA266240R0444
|
ALUM BOLTED TERMINAL 4HNP @ 45 (Bolted Aluminum Connector, Type A7M-45, Bolted Terminal, Cable to Flat at 45 Degree. 4 inch, 4-Hole NEMA Flat. Cable Size AAC 1/0-400, Cable Size ACSR 1/0-336, Cable Diameter .368-.741 inch, 3 inch X 9/16 inch. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides.)
|
ABB
|
|
7TAA266240R0443
|
ALUM BOLTED TERMINAL 2HNP (Bolted Aluminum Connector, Type A7M - Bolted Terminal, Cable to Flat, Cable Size AAC 1100-2500, Cable Size ACSR 1113-2300, Cable Diameter 1.209-1.823 inch, 10-7/8 X 3-3/4 inch X 1/2 inch thick. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides.)
|
ABB
|
|
7TAA266240R0442
|
ALUM BOLT TERMINAL PIPE TO 6HNP (Bolted Aluminum Connector, Bolted Terminal, 4 inch Pipe to Flat. 6 Hole NEMA Pad, wide)
|
ABB
|
|
7TAA266240R0441
|
ALUM BOLTED TERMINAL 6HNP (Aluminum Bolted Substation Terminal (Straight - Side Formed Pad) - 2 Cables to Pad - 1100-2500AAC 1113-2300ACSR to 6 x 4 inch 6-hole Pad)
|
ABB
|
|
7TAA266240R0440
|
ALUM BOLTED TERMINAL 6HNP @90 (Aluminum Bolted Substation Terminal (90 Degree) - 2 Cables to Pad - 1100-2500AAC 1113-2300ACSR to 6 x 4 inch 6-hole Pad at 90 Degrees)
|
ABB
|
|
7TAA266240R0439
|
BOLTED ALUMINUM TERMINAL (Bolted Aluminum Connector, Type ABN-45, Bolted Terminal, Pipe to Flat at 45 Degrees. 4 Inch 4-Hole NEMA Flat. SPS is 4. 4-1/4 inch X 7/8 inch thick, Amps is 2460.)
|
ABB
|
|
7TAA266240R0436
|
ALUMINUM BOLTED TERMINAL (Bolted Aluminum Connector, Type A7MM1-45, Bolted Terminal, Two Cables to Flat at 45 Degree, One-Cap Design. Cable Size AAC 556-1500, Cable Size ACSR 636-1272, Cable Diameter .856-1.412 inch, 3-5/8 inch X 7/8 inch. Connectors supplied with clamping hardware in accordance with NEMA standard CC 1. All pads are finished on both sides.)
|
ABB
|