1SVR4

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
1SVR405501R4010 CR-S048VDC1R Pluggable interface relay 1c/o, A1-A2=48VDC, Output=6A/250VAC ABB
1SVR405501R3020 CR-S024VDC1RG Pluggable interface relay 1c/o, A1-A2=24VDC, Output=6A/250VAC (CR-S024VDC1RG Pluggable interface relay 1c/o, A1-A2=24VDC, Output=6A/250VAC gold-plated contacts) ABB
1SVR405501R3010 CR-S024VDC1R Pluggable interface relay 1c/o, A1-A2=24VDC, Output=6A/250VAC ABB
1SVR405501R2020 CR-S012VDC1RG Pluggable interface relay 1c/o, A1-A2=12VDC, Output=6A/250VAC (CR-S012VDC1RG Pluggable interface relay 1c/o, A1-A2=12VDC, Output=6A/250VAC gold-plated contacts) ABB
1SVR405501R2010 CR-S012VDC1R Pluggable interface relay 1c/o, A1-A2=12VDC, Output=6A/250VAC ABB
1SVR405501R1020 CR-S005VDC1RG Pluggable interface relay 1c/o, A1-A2=5VDC, Output=6A/250VAC (CR-S005VDC1RG Pluggable interface relay 1c/o, A1-A2=5VDC, Output=6A/250VAC gold-plated contacts) ABB
1SVR405501R1010 CR-S005VDC1R Pluggable interface relay 1c/o, A1-A2=5VDC, Output=6A/250VAC ABB
1SVR450334R0000 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC, L1/k-L1/l=5A,480-500VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 480-500 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 0.5-5 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450332R0100 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC,L1/k-L1/l=20A,380-440VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 380-440 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 2-20 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450332R0000 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC, L1/k-L1/l=5A,380-440VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 380-440 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 0.5-5 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450331R0100 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC,L1/k-L1/l=20A,220-240VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 220-240 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 2-20 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450331R0000 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC, L1/k-L1/l=5A,220-240VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 220-240 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 0.5-5 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450330R0100 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC,L1/k-L1/l=20A,110-130VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 110-130 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 2-20 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450330R0000 CM-LWN Motor load monitor, 2x1c/o L1-L2-L3=500VAC, L1/k-L1/l=5A,110-130VAC (The CM-LWN relay is from the CM motor load monitors range. This relay operates with a rated control supply voltage of 110-130 V AC, has a 2 x 1 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the closed-circuit principle. Its measuring principle is based on the evaluation of the phase shift between the voltage and the current in one phase of single- or three-phase asynchronous motors (squirrel cage). The measuring circuit is designed for measuring voltages of 110-500 V AC and measuring currents of 0.5-5 A AC. The window (over- and underload) monitoring allows setting of two individual threshold values, one for maximum load and one for minimim load. The hysteresis is fixed at 4 ?? related to the phase angle. The tripping delay is adjustable within a range of 0.2 to 2 s and the start-up delay within a range of 0.3 to 30 s. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450215R0100 CM-ESN Voltage monitoring relay 2c/o, B-C=1-100VAC/DC, 24-240VAC/DC (Voltage monitoring relay CM-ESN, monitoring of over- or undervoltage, width 45mm, 3 measuring ranges B1,2,3-C=1-100V AC / DC, A1-A2=24-240V AC / DC, 2 c/o (opened circuit principle)) ABB
1SVR450118R1000 CM-CT-A Snap-on fastener for DIN rail mounting of CM-CT (The CM-CT-A is accessory from the CM-CT range. It can be used as snap-on mounting for CM-CT current transformers on DIN rail.) ABB
1SVR450117R5400 CM-CT 600/5 Current transformer 5VA, class 1 (The CM-CT 600/5 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 600 A and a secondary rated current of 5 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 600/5 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450117R5200 CM-CT 400/5 Current transformer 5VA, class 1 (The CM-CT 400/5 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 400 A and a secondary rated current of 5 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 400/5 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450117R5100 CM-CT 300/5 Current transformer 5VA, class 1 (The CM-CT 300/5 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 300 A and a secondary rated current of 5 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 300/5 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450117R1400 CM-CT 600/1 Current transformer 5VA, class 1 (The CM-CT 600/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 600 A and a secondary rated current of 1 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 600/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450117R1300 CM-CT 500/1 Current transformer 5VA, class 1 (The CM-CT 500/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 500 A and a secondary rated current of 1 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 500/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450117R1200 CM-CT 400/1 Current transformer 5VA, class 1 (The CM-CT 400/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 400 A and a secondary rated current of 1 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 400/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450116R5400 CM-CT 200/5 Current transformer 5VA, class 1 (The CM-CT 200/5 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 200 A and a secondary rated current of 5 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 200/5 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450116R5100 CM-CT 75/5 Current transformer 1.5VA, class 1 (The CM-CT 75/5 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 75 A and a secondary rated current of 5 A. The burden of the current transformer is 1.5 VA and its precision is according to class 1. The CM-CT 75/5 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450116R1400 CM-CT 200/1 Current transformer 2.5VA, class 1 (The CM-CT 200/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 200 A and a secondary rated current of 1 A. The burden of the current transformer is 2.5 VA and its precision is according to class 1. The CM-CT 200/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450116R1300 CM-CT 150/1 Current transformer 2.5VA, class 1 (The CM-CT 150/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 150 A and a secondary rated current of 1 A. The burden of the current transformer is 2.5 VA and its precision is according to class 1. The CM-CT 150/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450116R1100 CM-CT 75/1 Current transformer 1.5VA, class 1 (The CM-CT 75/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 75 A and a secondary rated current of 1 A. The burden of the current transformer is 1.5 VA and its precision is according to class 1. The CM-CT 75/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450116R1000 CM-CT 50/1 Current transformer 1VA, class 1 (The CM-CT 50/1 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 50 A and a secondary rated current of 1 A. The burden of the current transformer is 1 VA and its precision is according to class 1. The CM-CT 50/1 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.) ABB
1SVR450099R1000 CM-KRN Contact protection relay 2c/o, w/o time delay, 24VAC/DC (The CM-KRN relay is from the CM contact protection relay range. This protection relay operates with a rated control supply voltage of 24 V AC / DC, has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A and works according to the open-circuit principle. It acts as two-position switch and protects and reduces load from sensitive control contacts. It can be used with or without latching function. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB
1SVR450099R0000 CM-KRN Contact protection relay 2c/o, w/o time delay, 24VAC (The CM-KRN relay is from the CM contact protection relay range. This protection relay operates with a rated control supply voltage of 24 V AC, has a 2 c/o (SPDT) output with contactst rated at 250 V / 4 A and works according to the open-circuit principle. It acts as two-position switch and protects and reduces load from sensitive control contacts. It can be used with or without latching function. A sealable transparent cover for protection against unauthorized changes is available as accessory.) ABB

Òîâàðû 271 - 300 èç 417
Íà÷àëî | Ïðåä. | 8 9 10 11 12 | Ñëåä. | Êîíåö Âñå