art.1SBL407001R4122 - AF96-30-22-41 24-60V50/60HZ Contactor (AF96 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electro | Quad Industry GmbH

Àðòèêóë: 1SBL407001R4122
Íàèìåíîâàíèå: AF96-30-22-41 24-60V50/60HZ Contactor (AF96 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block, side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated - Accessories: a wide range of accessories is available. Note: 2-stack contactors available in some countries: please consult your ABB representative.)
Ïðîèçâîäèòåëü: ABB


AF96-30-22-41

General Information

  • Extended Product Type:
    AF96-30-22-41
  • Product ID:
    1SBL407001R4122
  • EAN:
    3471523133402
  • Catalog Description:
    AF96-30-22-41 24-60V50/60HZ Contactor
  • Long Description:
    AF96 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block, side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated - Accessories: a wide range of accessories is available. Note: 2-stack contactors available in some countries: please consult your ABB representative.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    70 mm
  • Product Net Depth:
    149 mm
  • Product Net Height:
    125.5 mm
  • Product Net Weight:
    1.270 kg

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    2
  • Number of Auxiliary Contacts NC:
    2
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
    Auxiliary Circuit 50 / 60 Hz
    Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 ??C 130 A
    acc. to IEC 60947-5-1, q = 40 ??C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 ??C 130 A
    (690 V) 60 ??C 105 A
    (690 V) 70 ??C 90 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 60 ??C 96 A
    (380 / 400 V) 60 ??C 96 A
    (415 V) 60 ??C 96 A
    (440 V) 60 ??C 96 A
    (500 V) 60 ??C 80 A
    (690 V) 60 ??C 57 A
    (1000 V) 60 ??C 30 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 25 kW
    (380 / 400 V) 45 kW
    (400 V) 45 kW
    (415 V) 55 kW
    (440 V) 55 kW
    (500 V) 55 kW
    (690 V) 55 kW
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (400 / 440 V) 3 A
    (500 V) 2 A
    (690 V) 2 A
  • Rated Short-time Withstand Current (Icw):
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
  • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-15 1200 cycles per hour
    AC-2 / AC-4 150 cycles per hour
    AC-3 1200 cycles per hour
    DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (110 V) 0.55 A / 60 W
    (125 V) 0.55 A / 69 W
    (220 V) 0.27 A / 60 W
    (24 V) 6 A / 144 W
    (250 V) 0.27 A / 68 W
    (400 V) 0.15 A / 60 W
    (48 V) 2.8 A / 134 W
    (500 V) 0.13 A / 65 W
    (600 V) 0.1 A / 60 W
    (72 V) 1 A / 72 W
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 24 ... 60 V
    60 Hz 24 ... 60 V
  • Operate Time:
    Between Coil De-energization and NC Contact Closing 19 ... 105 ms
    Between Coil De-energization and NO Contact Opening 17 ... 100 ms
    Between Coil Energization and NC Contact Opening 38 ... 95 ms
    Between Coil Energization and NO Contact Closing 42 ... 100 ms
  • Connecting Capacity Main Circuit:
    Flexible with Insulated Ferrule 1/2x 6...50 mm??
    Flexible with Ferrule 1/2x 6...50 mm??
    Rigid 1x 6...70 mm??
    Rigid 2x 6...50 mm??
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm??
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm??
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm??
    Rigid 1/2x 1...2.5 mm??
  • Connecting Capacity Control Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm??
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm??
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm??
    Rigid 1/2x 1 ... 2.5 mm??
  • Wire Stripping Length:
    Main Circuit 17 mm
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60...+80 ??C
    Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 ??C
    Close to Contactor without Thermal O/L Relay -40 ... +70 ??C
  • Climatic Withstand:
    Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5 ... 300 Hz 3 g closed position / 3 g open position
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: A 25 g
    Closed, Shock Direction: B1 25 g
    Closed, Shock Direction: B2 15 g
    Closed, Shock Direction: C1 25 g
    Closed, Shock Direction: C2 25 g
    Open, Shock Direction: B1 5 g

Technical UL/CSA

  • Horsepower Rating UL/CSA:
    (120 V AC) Single Phase 7-1/2 Hp
    (240 V AC) Single Phase 20 Hp
    (200 ... 208 V AC) Three Phase 30 Hp
    (220 ... 240 V AC) Three Phase 30 Hp
    (440 ... 480 V AC) Three Phase 60 Hp
    (550 ... 600 V AC) Three Phase 75 Hp
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 11 in??lb
    Control Circuit 11 in??lb
    Main Circuit 53 in??lb

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    180 mm
  • Package Level 1 Length:
    150 mm
  • Package Level 1 Height:
    102 mm
  • Package Level 1 Gross Weight:
    1.27 kg
  • Package Level 1 EAN:
    3471523133402
  • Package Level 2 Units:
    6 piece
  • Package Level 2 Width:
    250 mm
  • Package Level 2 Length:
    300 mm
  • Package Level 2 Height:
    300 mm
  • Package Level 3 Units:
    144 piece

Classifications

  • Object Classification Code:
    Q
  • ETIM 4:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 6:
    EC000066 - Power contactor, AC switching
  • UNSPSC:
    39121529




Image 0 alt text

Categories

  • Products ?? Low Voltage Products and Systems ?? Control Products ?? Contactors ?? Block Contactors


Íàçàä â ðàçäåë