art.1SAZ211201R1051 - TA25DU-25 Thermal Overload Relay (The TA25DU-25 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has tri | Quad Industry GmbH

Àðòèêóë: 1SAZ211201R1051
Íàèìåíîâàíèå: TA25DU-25 Thermal Overload Relay (The TA25DU-25 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.)
Ïðîèçâîäèòåëü: ABB


TA25DU-25

General Information

  • Extended Product Type:
    TA25DU-25
  • Product ID:
    1SAZ211201R1051
  • EAN:
    4013614216633
  • Catalog Description:
    TA25DU-25 Thermal Overload Relay
  • Long Description:
    The TA25DU-25 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    44 mm
  • Product Net Height:
    80 mm
  • Product Net Depth:
    94 mm
  • Product Net Weight:
    0.17 kg

Popular Downloads

Technical

  • Setting Range:
    18 ... 25 A
  • Rated Operational Voltage:
    Auxiliary Circuit 440 V DC
    Auxiliary Circuit 500 V AC
    Main Circuit 690 V AC
  • Rated Operational Current (Ie):
    25 A
  • Rated Operational Current AC-3 (Ie):
    25 A
  • Rated Frequency (f):
    Auxiliary Circuit 50 Hz
    Auxiliary Circuit 60 Hz
    Auxiliary Circuit DC
    Main Circuit 60 Hz
    Main Circuit 50 Hz
    Main Circuit DC
  • Rated Impulse Withstand Voltage (Uimp):
    Auxiliary Circuit 6 kV
    Main Circuit 6 kV
  • Rated Insulation Voltage (Ui):
    690 V
  • Number of Poles:
    3
  • Number of Auxiliary Contacts NC:
    1
  • Number of Auxiliary Contacts NO:
    1
  • Number of Protected Poles:
    3
  • Conventional Free-air Thermal Current (Ith):
    Auxiliary Circuit NC 10 A
    Auxiliary Circuit NO 6 A
  • Rated Operational Current AC-15 (Ie):
    (120 V) NC 3 A
    (120 V) NO 1.5 A
    (240 V) NC 3 A
    (240 V) NO 1.5 A
    (400 V) NC 1.9 A
    (400 V) NO 1 A
    (440 V) NC 1 A
    (440 V) NO 1 A
    (500 V) NC 1 A
    (500 V) NO 1 A
  • Rated Operational Current DC-13 (Ie):
    (125 V) NC 0.25 A
    (125 V) NO 0.25 A
    (24 V) NC 1.25 A
    (24 V) NO 1.25 A
    (250 V) NC 0.12 A
    (250 V) NO 0.04 A
    (60 V) NC 0.25 A
    (60 V) NO 0.25 A
  • Degree of Protection:
    Housing IP20
    Main Circuit Terminals IP10
  • Pollution Degree:
    3
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm??
    Flexible 1/2x 0.75 ... 2.5 mm??
    Rigid 1/2x 0.75 ... 4 mm??
  • Connecting Capacity Main Circuit:
    Flexible with Ferrule 1/2x 1.5 ... 4 mm??
    Flexible 1/2x 1.5 ... 4 mm??
    Rigid 1/2x 1.5 ... 6 mm??
  • Tightening Torque:
    Auxiliary Circuit 1 ... 1.3 N??m
    Main Circuit 1.5 ... 1.9 N??m
  • Wire Stripping Length:
    Auxiliary Circuit 9 mm
    Main Circuit 12 mm
  • Recommended Screw Driver:
    Main Circuit Pozidriv 2
  • Mounting Position:
    Position 1 to 4
  • Power Loss:
    at Rated Operating Conditions per Pole 1.5 ... 2.9 W
  • Suitable For:
    A9
    A12
    A16
    A26
    A30
    A40
    AL9
    AL12
    AL16
    AL26
    AL30
    AL40
  • Standards:
    IEC/EN 60947-1
    IEC/EN 60947-4-1
    IEC/EN 60947-5-1
    UL 60947-1
    UL 60947-4-1

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +55 ??C
    Operation Compensated -25 ... +55 ??C
    Storage -40 ... +70 ??C
  • Ambient Air Temperature Compensation:
    Yes
  • Maximum Operating Altitude Permissible:
    2000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    11 ms Pulse 12g
  • RoHS Status:
    Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V AC
  • Ampere Rating UL/CSA:
    25 A
  • Contact Rating UL/CSA:
    (NC:) B600
    (NO:) C300
  • Connecting Capacity Main Circuit UL/CSA:
    Flexible 1/2x 16-8 AWG
    Stranded 1/2x 16-8 AWG
  • Connecting Capacity Auxiliary Circuit UL/CSA:
    Flexible 1/2x 18-14 AWG
    Stranded 1/2x 18-14 AWG
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 12 in??lb
    Main Circuit 12 in??lb

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    98 mm
  • Package Level 1 Height:
    82 mm
  • Package Level 1 Length:
    47 mm
  • Package Level 1 Gross Weight:
    0.19 kg
  • Package Level 2 Units:
    48 piece
  • Package Level 2 Width:
    280 mm
  • Package Level 2 Height:
    210 mm
  • Package Level 2 Length:
    395 mm
  • Package Level 2 Gross Weight:
    9.506 kg
  • Package Level 2 EAN:
    4013614442025

Classifications

  • Object Classification Code:
    F
  • E-nummer:
    3228574
  • ETIM 4:
    EC000106 - Thermal overload relay
  • ETIM 5:
    EC000106 - Thermal overload relay
  • ETIM 6:
    EC000106 - Thermal overload relay
  • eClass:
    7.0 27371501
  • UNSPSC:
    39121521




Image 0 alt text

Categories

  • Products >> Low Voltage Products and Systems >> Control Products >> Contactors >> Thermal Overload Relays


Íàçàä â ðàçäåë