1SAM1

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
1SAM150000R1013 MS325-20 Manual Motor Starter (The MS325-20 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 20 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 55 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1012 MS325-16 Manual Motor Starter (The MS325-16 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 16 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 60 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1011 MS325-12.5 Manual Motor Starter (The MS325-12.5 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 12.5 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 75 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1010 MS325-9 Manual Motor Starter (The MS325-9 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 9.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1009 MS325-6.3 Manual Motor Starter (The MS325-6.3 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 6.3 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1008 MS325-4 Manual Motor Starter (The MS325-4 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 4.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1007 MS325-2.5 Manual Motor Starter (The MS325-2.5 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 2.5 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1006 MS325-1.6 Manual Motor Starter (The MS325-1.6 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 1.6 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1005 MS325-1 Manual Motor Starter (The MS325-1 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 1.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1004 MS325-0.63 Manual Motor Starter (The MS325-0.63 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 0.63 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1003 MS325-0.4 Manual Motor Starter (The MS325-0.4 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 0.4 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1002 MS325-0.25 Manual Motor Starter (The MS325-0.25 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 0.25 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM150000R1001 MS325-0.16 Manual Motor Starter (The MS325-0.16 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 0.16 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.) ABB
1SAM101924R0013 MSOX-30 Driver Shaft (MSOX-30 Driver shaft, turned for fixing of external operator, 6x6) ABB
1SAM101924R0003 MSOX-32 Driver Shaft (MSOX-32 Driver shaft for fixing of external operator, 6x6) ABB
1SAM101923R0012 MSMNO Driver (MSMNO Driver w/o coding w. screw for manual motor staters, 6x6) ABB
1SAM101923R0002 MSMN Driver (MSMN Driver w. screw for manual motor staters, 6x6) ABB
1SAM101938R0004 S3-M3 Power Infeed Block (S3-M3 Power infeed block, UL508-type E) ABB
1SAM101938R0002 S3-M2 Power Infeed Block (S3-M2 Power infeed block, high) ABB
1SAM101938R0001 S3-M1 Power Infeed Block (S3-M1 Power infeed block, flat) ABB
1SAM101904R0003 SK-11 Signal Contact (SK-11 Signal contact 1NO+1NC) ABB
1SAM101904R0002 SK-01 Signal Contact ABB
1SAM101904R0001 SK-10 Signal Contact ABB
1SAM101905R0001 AS Connection Module ABB
1SAM101938R0003 BS3-3 Protection Cover (BS3-3 Protection cover for busbar empty places) ABB
1SAM101941R1001 DMS325-Y Door Mounting Kit (DMS325-Y door mounting kit is suitable for manual motor starter MS325. The combination of manual motor starter and door mounting kit allows to setup all required control and protection functions for single machine installations. The door mounting kit has a IP65 degree of protection and can be easily integrated in cubicals and machines. Additional mounting of auxiliary and signalling contacts, shunt trips and undervoltage release is possible. The handle is 3-times lockable in OFF position.) ABB
1SAM101941R1000 DMS325-G Door Mounting Kit (DMS325-G door mounting kit is suitable for manual motor starter MS325. The combination of manual motor starter and door mounting kit allows to setup all required control and protection functions for single machine installations. The door mounting kit has a IP65 degree of protection and can be easily integrated in cubicals and machines. Additional mounting of auxiliary and signalling contacts, shunt trips and undervoltage release is possible. The handle is 3-times lockable in OFF position.) ABB
1SAM150000R0009 Motor protection switch MS325- ABB
1SAM101943R0001 CK-11 Short Circuit Signaling Contact ABB
1SAM101933R0001 PA25 Soldering Print Adaptor (PA25 soldering print adapter for MS325) ABB

Òîâàðû 31 - 60 èç 72
Íà÷àëî | Ïðåä. | 1 2 3 | Ñëåä. | Êîíåö Âñå