art.1SAZ711201R1033 - T16-3.1 Thermal Overload Relay 2.30 ... 3.10 A | 1SAZ711201R1033 | T16-3.1 | Quad Industry GmbH

Àðòèêóë: 1SAZ711201R1033
Íàèìåíîâàíèå: T16-3.1 Thermal Overload Relay 2.30 ... 3.10 A | 1SAZ711201R1033 | T16-3.1
Ïðîèçâîäèòåëü: ABB


General Information
Extended Product Type:
T16-3.1
Product ID:
1SAZ711201R1033
EAN:
4013614397912
Catalog Description:
T16-3.1 Thermal Overload Relay
Long Description:
The T16-3.1 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the mini contactors or block contactors. Single mounting kits are available as accessory.
 
 
  Accessories
Identifier Type Description
1SAZ701901R0001 DB16 DB16 Single Mounting Kit
Ordering
EAN:
4013614397912
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Dimensions
Product Net Width:
45.0 mm
Product Net Height:
76.7 mm
Product Net Depth:
53.5 mm
Product Net Weight:
0.100 kg
Container Information
Package Level 1 Units:
1 piece
Package Level 1 Width:
48.0 mm
Package Level 1 Length:
82.0 mm
Package Level 1 Height:
63.0 mm
Package Level 1 Gross Weight:
0.112 kg
Package Level 2 Units:
72 piece
Package Level 2 Width:
280.0 mm
Package Level 2 Length:
395.0 mm
Package Level 2 Height:
210.0 mm
Package Level 2 Gross Weight:
8.450 kg
Package Level 2 EAN:
4013614440625
Technical
Setting Range:
2.30 ... 3.10 A
Rated Operational Voltage (Ue):
Main Circuit 690 V AC
Rated Operational Current (Ie):
3.10 A
Rated Operational Current AC-3 (Ie):
3.10 A
Rated Frequency (fr):
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit DC
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Auxiliary Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Number of Poles:
3
Number of Auxiliary Contacts NC:
1
Number of Auxiliary Contacts NO:
1
Conventional Free-air Thermal Current (Ith):
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
Rated Operational Current AC-15 (Ie):
(120V) NC 3 A
(240V) NC 3 A
(400V) NC 0.75 A
(500V) NC 0.75 A
(120V) NO 0.75 A
(240V) NO 0.75 A
(400V) NO 0.75 A
(500V) NO 0.75 A
Rated Operational Current DC-13 (Ie):
(24V) NC 1.25 A
(60V) NC 0.55 A
(125V) NC 0.55 A
(250V) NC 0.27 A
(500V) NC 0.15 A
(24V) NO 1.25 A
(60V) NO 0.55 A
(125V) NO 0.55 A
(250V) NO 0.27 A
(500V) NO 0.15 A
Degree of Protection:
IP20
Pollution Degree:
3
Connecting Capacity-Auxiliary Circuit:
Rigid 1/2x 0.75 ... 4 mm?
Flexible with Ferrule 1/2x 0.75 ... 4 mm?
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm?
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm?
Flexible 1/2x 0.75 ... 1 mm?
Flexible 1/2x 1 ... 2.5 mm?
Connecting Capacity-Main Circuit:
Stranded 1/2x 1 ... 4 mm?
Solid 1/2x 0.75 ... 1.5 mm?
Solid 1/2x 1.5 ... 4 mm?
Flexible with Ferrule 1/2x 0.75 ... 4 mm?
Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm?
Flexible 1/2x 0.75 ... 4 mm?
Tightening Torques:
Main Circuit 1.1 ... 1.5 N·m
Auxiliary Circuit 1 ... 1.5 N·m
Wire Stripping Length:
Main Circuit 12 mm
Auxiliary Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
Position 1 to 5
Power Loss:
Per Pole 1.1 ... 2.0 W
Suitable For:
B6
BC6
B7
BC7
VB6
VBC6
VB7
VBC7
AS09
AS12
AS16
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL508, CSA 22.2 No. 14
Environmental
Ambient Air Temperature:
Operation -25 …. +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 …+80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 22g
Resistance to Vibrations acc. to IEC 60068-2-6:
3g / 3 … 150 Hz
RoHS Status:
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Ampere Rating UL/CSA:
3.10 A
Connecting Capacity-Main Circuit UL/CSA:
Stranded 1/2x 18 ... 10 AWG
Flexible 1/2x 18 ... 12 AWG
Connecting Capacity-Auxiliary Circuit UL/CSA:
Stranded 1/2x 18 ... 12 AWG
Flexible 1/2x 18 ... 12 AWG
Tightening Torques UL/CSA:
Main Circuit 9 ... 13 in·lb
Auxiliary Circuit 9 ... 13 in·lb
Certificates and Declarations (Document Number)
ABS Certificate:
CB Certificate:
CCC Certificate:
DNV Certificate:
Data Sheet, Technical Information:
Data Sheet, Technical Information (Part 2):
Declaration of Conformity - CE:
Dimension Diagram:

Íàçàä â ðàçäåë