AF16Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF..Z contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. AF..Z contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF..Z contactors allow direct control by PLC-output тЙе 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz AF..Z contactors have built-in surge protection and do not require additional surge suppressors The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated for AF..Z-30-..-20 contactors. Only AF..Z-30-..-20 contactors need to respect the polarity on the coil terminals (A1+ and A2-). - Accessories: a wide range of accessories is available.
Ordering
EAN:
3471523113909
Minimum Order Quantity:
1 piece
Country of Origin:
France (FR)
Customs Tariff Number:
85369085
Dimensions
Product Net Width:
45 mm
Product Net Depth:
77 mm
Product Net Height:
86 mm
Product Net Weight:
0.310 kg
Container Information
Package Level 1 Units:
1 piece
Package Level 1 Width:
87 mm
Package Level 1 Length:
79 mm
Package Level 1 Height:
47 mm
Package Level 1 Gross Weight:
0.330 kg
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 ??C
Close to Contactor for Storage -60 ... +80 ??C
Close to Contactor without Thermal O/L Relay -40 ... +70 ??C
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Shock Direction: A 30 gn
Closed, Shock Direction: B1 25 gn
Open, Shock Direction: B1 5 gn
Shock Direction: B2 15 gn
Shock Direction: C1 25 gn
Shock Direction: C2 25 gn
Resistance to Vibrations acc. to IEC 60068-2-6:
5 ... 300 Hz 4 g Closed position / 2 g Open position
RoHS Status:
Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1