art.2104372-007 - XMTR,MV,1000"/6000 PSI,CSA,NO LCD,SP,269 (Multivariable, ABB 269CS, 1000 inch/6000 pounds,) | Quad Industry GmbH

Артикул: 2104372-007
Наименование: XMTR,MV,1000"/6000 PSI,CSA,NO LCD,SP,269 (Multivariable, ABB 269CS, 1000 inch/6000 pounds,)
Производитель: ABB


2104372-007

General Information

  • Product ID:
    2104372-007
  • ABB Type Designation:
    -
  • Catalog Description:
    XMTR,MV,1000"/6000 PSI,CSA,NO LCD,SP,269
  • Long Description:
    Multivariable, ABB 269CS, 1000 inch/6000 pounds,
    with local keys, without display, Pressure Transmitter Device

Additional Information

  • ABB Type Designation:
    -
  • Country of Origin:
    Germany (DE)
  • Customs Tariff Number:
    90262040
  • Gross Weight:
    0 kg
  • Invoice Description:
    XMTR,MV,1000"/6000 PSI,CSA,NO LCD,SP,269
  • Made To Order:
    No
  • Minimum Order Quantity:
    1 EA
  • Order Multiple:
    1 EA
  • Part Type:
    New
  • Product Name:
    -
  • Product Net Weight:
    0 kg
  • Quote Only:
    No
  • Selling Unit of Measure:
    each
  • Stocked At (Warehouses):
    USABB005EXPU
  • Technical Information:
    XMTR,MV,1000"/6000 PSI,CSA,NO LCD,SP,269 SERIES PN:2104372 -
    007
    ABB MINDEN #269CSL4KA5A5EMW59
    ********************************************************
    269CS -
    BASE NUMBER
    L -
    DIFFERENTIAL PRESSURE = 1000" WATER
    4 -
    6000 PSI (5945 PSI)
    K -
    SILICONE FLUID / HASTELLOY C276 DIAPHRAGM
    A -
    PROCESS FLANGES, 316 SST, HORIZONTAL
    1/4 -
    18 NPT -
    f DIRECT (7/16 UNF U.S.THREAD)
    5 -
    SST BOLTS / FLANGE, O -
    RINGS EPDM
    A -
    ALUMINUM BARREL HOUSING / 1/2 NPT
    5 -
    MODBUS OUTPUT, RS -
    485
    DRAIN/VENT, NOT SELECTED
    EM -
    ELECTRICAL CERTIFICATION, CSA EXPLOSION PROOF
    W59 -
    CUSTOM MODBUS CONFIGURATION:
    -
    Modbus Address = 1
    -
    Baud Rate = 9600
    -
    No Shift
    -
    Damping = .125
    -
    Static Pressure Response Delay = .125 (Sp Dampening)
    -
    Response Delay = 20 milliseconds
    -
    Device Mode = Operate
    -
    Leave unit in "user text" operating mode
    so unit will accept our names & units
    download from Xseries.
    -
    W/WITH SURGE PROTECTION





Назад в раздел