art.1SBL161001R3410 - A12-30-10 175V 50Hz / 208V 60Hz Contactor (A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation | Quad Industry GmbH

Артикул: 1SBL161001R3410
Наименование: A12-30-10 175V 50Hz / 208V 60Hz Contactor (A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.)
Производитель: ABB
Картинки описания: 1SFC101044F0202_720.jpg, 1SFC101043F0202_720.jpg, acrosstheline.jpg, CP_Block_Contactors.jpg, 1SBC101292F0010_720.jpg, 1SFC101043F0201_720.jpg


A12-30-10 175V 50Hz / 208V 60Hz

General Information

  • Extended Product Type:
    A12-30-10 175V 50Hz / 208V 60Hz
  • Product ID:
    1SBL161001R3410
  • EAN:
    3471522042347
  • Catalog Description:
    A12-30-10 175V 50Hz / 208V 60Hz Contactor
  • Long Description:
    A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    44 mm
  • Product Net Depth:
    74 mm
  • Product Net Height:
    74 mm
  • Product Net Weight:
    0.340 kg

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    0
  • Standards:
    Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
  • Rated Operational Voltage:
    Main Circuit 690 V
  • Rated Frequency (f):
    Supply Circuit 50 Hz
    Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 ??C 28 A
    acc. to IEC 60947-5-1, q = 40 ??C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 ??C 27 A
    (690 V) 55 ??C 25 A
    (690 V) 70 ??C 20 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 55 ??C 12 A
    (380 / 400 V) 55 ??C 12 A
    (415 V) 55 ??C 12 A
    (440 V) 55 ??C 12 A
    (500 V) 55 ??C 12 A
    (690 V) 55 ??C 9 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 3 kW
    (380 / 400 V) 5.5 kW
    (415 V) 5.5 kW
    (440 V) 5.5 kW
    (500 V) 7.5 kW
    (690 V) 7.5 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (380 / 440 V) 3 A
    (500 V) 2 A
    (690 V) 2 A
  • Short-Circuit Protective Devices:
    Auxiliary Circuit - gG Type Fuses 10 A
    gG Type Fuses 32 A
  • Rated Short-time Withstand Current (Icw):
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 15 min 28 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 s 280 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 30 s 70 A
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
  • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-2 / AC-4 300 cycles per hour
    AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (125 V) 1.1 / 138 A
    (24 V) 6 / 144 A
    (250 V) 0.55 / 138 A
    (48 V) 2.8 / 134 A
    (72 V) 2 / 144 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    10 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ?? тЙд 55 ??C) ??C
  • Rated Control Circuit Voltage (Uc):
    50 Hz 175 V
    60 Hz 208 V
  • Coil Consumption:
    Average Holding Value 50 Hz 8 V??A
    Average Holding Value 50 Hz 2 W
    Average Holding Value 60 Hz 8 V??A
    Average Holding Value 60 Hz 2 W
    Average Pull-in Value 50 Hz 70 V??A
    Average Pull-in Value 60 Hz 80 V??A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 10 ... 26 ms
    Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Connecting Capacity Main Circuit:
    Flexible with Cable End 0.75 ... 2.5 mm??
    Rigid Cable 1 ... 4 mm??
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Cable End 0.75 ... 2.5 mm??
    Rigid Cable 1 ... 4 mm??
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    M 3.5 (+,-) pozidriv 2 screws with cable clamp
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 ??C
    Close to Contactor for Storage -60 ... +80 ??C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 ??C
    Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 ??C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Shock Direction: A 20 g
    Closed, Shock Direction: B1 10 g
    Open, Shock Direction: B1 5 g
    Shock Direction: B2 15 g
    Shock Direction: C1 20 g
    Shock Direction: C2 20 g
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    78 mm
  • Package Level 1 Length:
    76 mm
  • Package Level 1 Height:
    47 mm
  • Package Level 1 Gross Weight:
    0.34 kg
  • Package Level 1 EAN:
    3471522042347
  • Package Level 2 Units:
    63 piece
  • Package Level 3 Units:
    1220 piece

Classifications

  • Object Classification Code:
    Q
  • ETIM 4:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 6:
    EC000066 - Power contactor, AC switching
  • UNSPSC:
    39121529




Image 0 alt text
Image 1 alt text
Image 2 alt text
Image 3 alt text
Image 4 alt text
Image 5 alt text

Categories

  • Products ?? Low Voltage Products and Systems ?? Control Products ?? Contactors ?? Block Contactors


Назад в раздел