art.1SBL183510R8100 - AL16-22-00RT 24V DC Contactor (AL16 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. The contactors can also | Quad Industry GmbH
Àðòèêóë: 1SBL183510R8100
Íàèìåíîâàíèå: AL16-22-00RT 24V DC Contactor (AL16 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. The contactors can also be used for many other applications such lighting... The AL..RT contactors are the Ring Tongue terminal version of the AL... range. The AL... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. AL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.)
Ïðîèçâîäèòåëü: ABB
AL16-22-00RT 24V DC
General Information
Extended Product Type:
AL16-22-00RT 24V DC
Product ID:
1SBL183510R8100
EAN:
3471522360915
Catalog Description:
AL16-22-00RT 24V DC Contactor
Long Description:
AL16 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. The contactors can also be used for many other applications such lighting... The AL..RT contactors are the Ring Tongue terminal version of the AL... range. The AL... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. AL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
acc. to IEC 60947-4-1, Open Contactors q = 40 ??C 30 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 ??C 30 A (690 V) 55 ??C 27 A (690 V) 70 ??C 23 A
Short-Circuit Protective Devices:
gG Type Fuses 32 A
Rated Short-time Withstand Current (Icw):
at 40 ??C Ambient Temp, in Free Air, from a Cold State 10 s 140 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 15 min 30 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Electrical Switching Frequency:
AC-1 600 cycles per hour
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Mechanical Durability:
10 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ?? òÉä 55 ??C) ??C
Rated Control Circuit Voltage (Uc):
DC Operation 24 V
Coil Consumption:
Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W
Operate Time:
Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms Between Coil De-energization and NC Contact Closing 16 ... 27 ms Between Coil Energization and NC Contact Opening 20 ... 70 ms
Rigid or Flexible with Cable Lug 0.75 ... 2.5 mm??
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting terminals (delivered in open position) Main poles:
M 3.5 (+,-) pozidriv 2 screw with conic washer
Terminal Type:
Ring-Tongue Terminals
Environmental
Ambient Air Temperature:
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 ??C Near Contactor for Operation in Free Air (Uc) -40 ... +70 ??C Close to Contactor for Storage -60 ... +80 ??C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
RoHS Status:
Following EU Directive 2002/95/EC August 18, 2005 and amendment