art.1SBL183010R8101 - AL16-30-01RT 24V DC Contactor (AL16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor | Quad Industry GmbH

Àðòèêóë: 1SBL183010R8101
Íàèìåíîâàíèå: AL16-30-01RT 24V DC Contactor (AL16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AL..RT contactors are the Ring Tongue terminal version of the AL... range. The AL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. AL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.)
Ïðîèçâîäèòåëü: ABB


AL16-30-01RT 24V DC

General Information

  • Extended Product Type:
    AL16-30-01RT 24V DC
  • Product ID:
    1SBL183010R8101
  • EAN:
    3471522360717
  • Catalog Description:
    AL16-30-01RT 24V DC Contactor
  • Long Description:
    AL16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AL..RT contactors are the Ring Tongue terminal version of the AL... range. The AL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. AL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    44 mm
  • Product Net Depth:
    97 mm
  • Product Net Height:
    78 mm
  • Product Net Weight:
    0.520 kg

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    0
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 690 V
    Auxiliary Circuit 690 V
  • Rated Frequency (f):
    Supply Circuit 50 Hz
    Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 ??C 30 A
    acc. to IEC 60947-5-1, q = 40 ??C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 ??C 30 A
    (690 V) 55 ??C 27 A
    (690 V) 70 ??C 23 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 55 ??C 17 A
    (380 / 400 V) 55 ??C 17 A
    (415 V) 55 ??C 17 A
    (440 V) 55 ??C 16 A
    (500 V) 55 ??C 14 A
    (690 V) 55 ??C 10 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 4 kW
    (380 / 400 V) 7.5 kW
    (415 V) 9 kW
    (440 V) 9 kW
    (500 V) 9 kW
    (690 V) 9 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (380 / 440 V) 3 A
    (500 V) 2 A
    (690 V) 2 A
  • Short-Circuit Protective Devices:
    Auxiliary Circuit - gG Type Fuses 10 A
    gG Type Fuses 32 A
  • Rated Short-time Withstand Current (Icw):
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 10 s 140 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 15 min 30 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
    at 40 ??C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A
  • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-2 / AC-4 300 cycles per hour
    AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (125 V) 1.1 / 138 A
    (24 V) 6 / 144 A
    (250 V) 0.55 / 138 A
    (48 V) 2.8 / 134 A
    (72 V) 2 / 144 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    6 kV
  • Mechanical Durability:
    10 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ?? òÉä 55 ??C) ??C
  • Rated Control Circuit Voltage (Uc):
    DC Operation 24 V
  • Coil Consumption:
    Average Holding Value, from Warm State 3 W
    Average Pull-in Value, from Cold State 3 W
  • Operate Time:
    Between Coil Energization and NO Contact Closing 50 ... 100 ms
    Between Coil De-energization and NO Contact Opening 10 ... 17 ms
    Between Coil De-energization and NC Contact Closing 16 ... 27 ms
    Between Coil Energization and NC Contact Opening 20 ... 70 ms
  • Connecting Capacity Main Circuit:
    Rigid Cable 0.75 ... 2.5 mm??
    Flexible with Cable Lug 0.75 ... 2.5 mm??
  • Connecting Capacity Auxiliary Circuit:
    Rigid or Flexible with Cable Lug 0.75 ... 2.5 mm??
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP10
  • Connecting terminals (delivered in open position) Main poles:
    M 3.5 (+,-) pozidriv 2 screw with conic washer
  • Terminal Type:
    Ring-Tongue Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60 ... +80 ??C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 ??C
    Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 ??C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: A 20 g
    Open, Shock Direction: A 10 g
    Closed, Shock Direction: B1 15 g
    Open, Shock Direction: B1 5 g
    Shock Direction: B2 10 g
    Closed, Shock Direction: C1 20 g
    Open, Shock Direction: C1 8 g
    Closed, Shock Direction: C2 14 g
    Open, Shock Direction: C2 8 g
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    86 mm
  • Package Level 1 Length:
    141 mm
  • Package Level 1 Height:
    51 mm
  • Package Level 1 Gross Weight:
    0.52 kg
  • Package Level 1 EAN:
    3471522360717
  • Package Level 2 Units:
    28 piece
  • Package Level 3 Units:
    336 piece

Classifications

  • Object Classification Code:
    Q
  • ETIM 4:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 6:
    EC000066 - Power contactor, AC switching
  • UNSPSC:
    39121529




Image 0 alt text
Image 1 alt text
Image 2 alt text
Image 3 alt text
Image 4 alt text
Image 5 alt text

Categories

  • Products ?? Low Voltage Products and Systems ?? Control Products ?? Contactors ?? Block Contactors


Íàçàä â ðàçäåë