static: 32 mm dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing
500 mm
Number of beams
2
Operating mode
Start/restart disable, relay monitor,
Angle of divergence
< 5 В°
Functional safety related parameters
Safety Integrity Level (SIL)
SIL 3
Performance level (PL)
PL e
Category
Cat. 4
Mission Time (TM)
20 a
PFHd
3.54 E-9
Indicators/operating means
Diagnostics display
7-segment display
Function display
LED red: per receiver channel off: interruption flashes: receiver continuously on: reception with sufficient stability control on the front plate: LED red: OSSD off LED green: OSSD on
Pre-fault indication
LED red next to receiver flashes
Electrical specifications
Operating voltage
24 V DC -15% / +25% , galvanically isolated
Input
Function input
Relay monitor, start release
Output
Safety output
2 separated fail safe semiconductor outputs
Signal output
1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off
Mechanical specifications
Protection degree
IP65
Connection
M16 cable gland , terminal compartment with cage-terminals