Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
BQ3B090YL
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B030QXBP
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL QUICK CONNECT LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B070
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B090
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B015C
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B045H
|
3P 45A 240V CB _
|
Siemens
|
BQ3B060L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B060HC
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B020
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B090H
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B040QL
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B100HL
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQH FRAME; 240 VAC AT 60 HZ; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120/240 VAC; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 2.37 INCH D X 4 INCH H _
|
Siemens
|
BQ3B100HL
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQH FRAME; 240 VAC AT 60 HZ; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120/240 VAC; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 2.37 INCH D X 4 INCH H _
|
Siemens
|
BQ3B02000S07
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B015H
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B080L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B035L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ2B02000S07
|
BREAKER SHUNT TRIP, STANDARD; 24 V AC VOLTAGE; APPROVAL UL; USED ON BQ CIRCUIT BREAKER _
|
Siemens
|
BQ3B020L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B030L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B03000S01
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _
|
Siemens
|
BQ3B040HL
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B01500S01
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _
|
Siemens
|
BQ3B050H00S01
|
3P 50A 240V CB _
|
Siemens
|
BQ3B030QXBP
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL QUICK CONNECT LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B030LBP
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ2B02000S07
|
BREAKER SHUNT TRIP, STANDARD; 24 V AC VOLTAGE; APPROVAL UL; USED ON BQ CIRCUIT BREAKER _
|
Siemens
|
Q360E
|
3P 60A 240V CB _
|
Siemens
|
BQ3B040
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B100H
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
Òîâàðû
91 - 120 èç 176
Íà÷àëî
|
Ïðåä.
|
2
3
4
5
6
|
Ñëåä. |
Êîíåö
| Âñå
|