| LOAD FEEDER FUSELESS REVERSING DUTY, AC 400V, SZ S00, 5,5. . .8A, DC 24V SCREW CONNECTION FOR BUSBAR SYSTEMS 60MM TYPE OF COORDINATION 1, IQ = 150KA 1NC (CONTACTOR) |
|
General technical data: |
product brand name | | SIRIUS |
product designation | | non-fused load feeders 3RA2 |
Design of the product | | reversing starter |
Size of the load feeder | | S00 |
Protection class IP / on the front | | IP20 |
Degree of pollution | | 3 |
Insulation voltage / rated value | V | 690 |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -55… +80 |
| °C | -55… +80 |
| °C | -20… +60 |
Impulse voltage resistance / rated value | kV | 6 |
Active power loss / per conductor / typical | W | 3.5 |
Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | Q |
- according to DIN EN 61346-2
| | Q |
Type of assignement | | 1 |
Mechanical operating cycles as operating time / of the contactor | | |
| | 10,000,000 |
Manufacturer article number | | |
- of the circuit-breakers included in the scope of supply
| | 3RV2011-1HA10 |
- of the contactor included in the scope of supply
| | 3RT2015-1BB42 |
- of the RS applied assembly kit
| | 8US1250-5AS10 |
- of the link module included in the scope of supply
| | 3RA1921-1DA00 |
- of the busbar adapter included in the scope of supply
| | 8US1251-5DS10 |
Design of the switching contact | | mechanical |
Type of the motor protection | | bimetal |
Adjustable response current | | |
- of the current-dependent overload release
| A | 5.5… 8 |
|
Communication: |
Product function / bus-communication | | No |
Protocol / will be supported | | |
| | No |
| | No |
| | No |
Product extension / function module for communication | | No |
|
Main circuit: |
Number of poles / for main current circuit | | 3 |
Number of NC contacts / for main contacts | | 0 |
Number of NO contacts / for main contacts | | 3 |
Operating voltage / at AC-3 / rated value / maximum | V | 690 |
Operating current | | |
- at AC-1 / at 400 V / rated value
| A | 8 |
- at AC-2 / at 400 V / rated value
| A | 6.5 |
- at AC-3 / at 400 V / rated value
| A | 6.5 |
- at AC-4 / at 400 V / rated value
| A | 6.5 |
Service power | | |
- at AC-2 / at 400 V / rated value
| W | 3,000 |
| | |
| W | 3,000 |
| W | 4,000 |
| W | 5,500 |
- at AC-4 / at 400 V / rated value
| W | 3,000 |
Off-load operating frequency | 1/h | 10,000 |
Frequency of operation | | |
- at AC-1 / according to IEC 60947-6-2 / maximum
| 1/h | 1,000 |
- at AC-2 / according to IEC 60947-6-2 / maximum
| 1/h | 750 |
- at AC-3 / according to IEC 60947-6-2 / maximum
| 1/h | 750 |
- at AC-4 / according to IEC 60947-6-2 / maximum
| 1/h | 250 |
|
Control circuit: |
Type of voltage / of the controlled supply voltage | | DC |
Control supply voltage frequency | | |
| Hz | 0 |
Control supply voltage / 1 | | |
| V | 24 |
Holding power / of the solenoid / for DC | W | 4 |
|
Auxiliary circuit: |
Product extension / auxiliary switch | | Yes |
Number of NC contacts / for auxiliary contacts | | 1 |
Number of NO contacts / for auxiliary contacts | | 0 |
Number of change-over switches / for auxiliary contacts | | 0 |
|
Inputs/ Outputs: |
Number of digital inputs | | 0 |
|
Short-circuit: |
Product function / short circuit protection | | Yes |
Design of the short-circuit protection | | circuit-breakers |
Breaking capacity limit short-circuit current (lcu) | | |
| A | 100,000 |
| A | 42,000 |
| A | 4,000 |
|
Installation/mounting/dimensions: |
Built in orientation | | vertical |
Type of mounting | | for snapping onto 60 mm busbar systems |
Width | mm | 90 |
Height | mm | 200 |
Depth | mm | 155.1 |