HHED62B110L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED62B025L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED62B125L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED63B015L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED62B125L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED62B020L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED63B040
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED62B080L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _
|
Siemens
|
HHED63M125
|
CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _
|
Siemens
|
HHED62B020
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _
|
Siemens
|
HHED63B025
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _
|
Siemens
|
HHED63M040
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B090L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B045L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED62M025
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _
|
Siemens
|
HHED63B050LAC
|
50A 3P 600V CB _
|
Siemens
|
HHED63B040L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B090L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B050
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED62B050L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _
|
Siemens
|
HHED63B080L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B070
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63M030
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B100L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B020LSN
|
CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _
|
Siemens
|
HHED62M015
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _
|
Siemens
|
HHED62B045
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED62B015L
|
THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _
|
Siemens
|
HHED63M060
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HHED63B030L
|
THERMAL MAGNETIC; 3 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _
|
Siemens
|