Catalogs > Safety Products Catalog > Logic > Safety Relays > Next Generation Safety Relays > Guardmaster® Safety Relays — DI, DIS, SI, CI, GLP, EM, and EMD
Guardmaster® Safety Relays — DI, DIS, SI, CI, GLP, EM, and EMD
Introduction | Specifications | Product Selection | Typical Configuration |
Accessories | Approximate Dimensions | Block Diagrams | Typical Wiring Diagram(s) |
Dual Input Relay (DI)
Safety Outputs (N.O.): 13-14, 23-24
|
Dual Input Solid State Output Relay (DIS)
Safety Outputs (PNP N.O.): 14 & 24 (1.5 A each max), 34 & 44 (0.5 A each max, for high capacitive loads)
|
Single Input Relay (SI)
Safety Outputs (N.O.): 13-14, 23-24
|
Single Input Relay Compatible Layout (CI)
Safety Outputs (N.O.): 13-14, 23-24, 33-34
|
Guardlocking with Proximity Sensors (GLP)
Safety Outputs (PNP N.O.): L11 (Single Wire Safety)
|
Expansion Module Relay (EM)
Safety Outputs (N.O.): 13-14, 23-24, 33-34, 43-44
|
Expansion Module Delayed Output Relay (EMD)
Delayed Safety Outputs (N.O.): 17-18, 27-28, 37-38,47-48
|
Common Terminals
Terminals | Relay | Description |
A1, A2 | All | Power |
S12, S22 | DI, DIS, SI, CI | IN1: Safety input 1 |
S32, S42 | DI, DIS | IN2: Safety input 2 |
S11, S21 | DI, DIS, SI, CI | Test outputs for safety inputs |
S34 | DI, DIS, SI, CI | Monitoring feedback loop for reset |
S44 | GLP | Lock request and reset |
S54 | GLP | Unlock request |
Y32 | DI, DIS, SI, GLP | Auxiliary PNP semiconductor output |
41-42 | CI | Auxiliary N.C. relay output |
X32 | EM, EMD | Feedback PNP semiconductor output |
L12 | DI, DIS, EM, EMD | Single wire safety input |
L11 | All | Single wire safety output |
B1, B2 | EMD | Configuration for retriggering/jogging |
51, L61 | GLP | Lock command to solenoid |
X14, X24 | GLP | Multifunction safety outputs |
AP, P12, P22 | GLP | Proximity sensor power and inputs |
Note:Output terminals described by image. |
Auxiliary/Feedback Output Behavior
Unit Status | DI, DIS, SI | CI | EM, EMD |
Y32 | 41-42 | X32 | |
Active & healthy | Off | Open | Off |
Inactive & healthy | 24V DC | Closed | 24V DC |
Fault | 24V DC | Closed | Off |
Unit Status | GLP | |
Y32 | ||
Cat 1 Stop | Off upon unlock request | 24V DC active & healthy |
Safe Limited Speed | 24V DC upon unlock request | Off active & healthy |
Fault | Off | Off |