PL4-F25-N4-K - Inductive sensor | PL4-F25-N4-K - Quad Industry GmbH

Артикул: PL4-F25-N4-K
Наименование: Inductive sensor | PL4-F25-N4-K
Производитель: Pepperl-Fuchs



  • For installation in housing
  • PL4... with 2 valve connections
  • Pluggable cage clamp terminals
  • Valve LEDs disconnectable (wire jumper)
  • Satisfies machinery directive
  • EC-Type Examination Certificate TГњV99 ATEX 1479X

Datasheet as PDF in following languages:


Technical Data: PL4-F25-N4-K

General specifications
Switching element functionDC Dual NC
Rated operating distance3 mm
Installationflush mountable
Output polarityNAMUR
Assured operating distance0 ... 2.43 mm
Reduction factor rAl 0.5
Reduction factor rCu
Reduction factor r304 1
Reduction factor rSt37 1.2
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Operating voltage5 ... 25 V
Switching frequency0 ... 100 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA
Switching state indicationLED, yellow
Valve status indication LED, yellow
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
Electromagnetic compatibilityNE 21:2007
Ambient conditions
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Storage temperature-40 ... 100 В°C (-40 ... 212 В°F)
Mechanical specifications
Connection (system side)Cage tension spring terminals
Core cross-section (system side)up to 2.5 mm2
Connection (valve side)Cage tension spring terminals
Core cross-section (valve side)up to 2.5 mm2
Housing materialPBT
Sensing facePBT
ATEX 1G
Specific conditions
Lead insertionThe connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also IEC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of IEC 60079-14, must be used.
ATEX 2G
Specific conditions
Lead insertionThe connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also IEC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of IEC 60079-14, must be used.
General information
Use in the hazardous areasee instruction manuals
Category1G; 2G; 3G