up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Nominal ratings
Nominal voltage
8 V DC
Switching frequency
0 ... 200 Hz
Hysteresis
typ. 0.1 %
Suitable for 2:1 technology
yes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected
≤ 1 mA
Measuring plate detected
≥ 3 mA
Functional safety related parameters
MTTFd
7660 a
Mission Time (TM)
20 a
Diagnostic Coverage (DC)
0 %
Approvals and certificates
FM approval
Control drawing
116-0165F
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
CCC approval
CCC approval / marking not required for products rated ≤36 V