General specifications |
Switching element function | DC Dual NC |
Rated operating distance | 3 mm |
Installation | flush mountable |
Output polarity | NAMUR |
Assured operating distance | 0 ... 2.4 mm |
Reduction factor rAl | 0.35 |
Reduction factor rCu | 0.3 |
Reduction factor r304 | 0.75 |
Reduction factor rSt37 | 1 |
Reduction factor rBrass | 0.45 |
Nominal ratings |
Nominal voltage | 8 V |
Switching frequency | 0 ... 3 kHz |
Hysteresis | typ. 5 % |
Short-circuit protection | yes |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Current consumption | |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
Switching state indication | LED, yellow |
Valve status indication | LED, yellow |
Compliance with standards and directives |
Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Mechanical specifications |
Connection (system side) | Cage tension spring terminals |
Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid |
Connection (valve side) | Cage tension spring terminals |
Core cross-section (valve side) | 1.5/2.5 mm2 flexible/rigid |
Housing material | PBT |
Sensing face | PBT |
Protection degree | IP67 |
Tightening torque, housing screws | 1 Nm |
Tightening torque, cable gland | M20 x 1.5 ; max. 7 Nm M12 x 1.5 ; max. 3 Nm |
Note | LED switch-off |
ATEX 1G |
Specific conditions | |
| Lead insertion | The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also IEC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of IEC 60079-14, must be used. |
ATEX 2G |
Specific conditions | |
| Lead insertion | The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also IEC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of IEC 60079-14, must be used. |
General information |
Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 3G |