General specifications |
Switching element function | NAMUR, NC |
Rated operating distance | 4 mm |
Installation | flush |
Output polarity | NAMUR |
Assured operating distance | 0 ... 3.24 mm |
Reduction factor rAl | 0.41 |
Reduction factor rCu | 0.39 |
Reduction factor r304 | 0.78 |
Nominal ratings |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
Switching frequency | 0 ... 1500 Hz |
Hysteresis | 1 ... 15 typ. 5 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | yes |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Current consumption | |
| Measuring plate not detected | min. 2.2 mA |
| Measuring plate detected | ≤ 1 mA |
Switching state indication | Multihole-LED, yellow |
Functional safety related parameters |
MTTFd | 3010 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives |
Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
Approvals and certificates |
FM approval | |
| Control drawing | 116-0165F |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Mechanical specifications |
Connection type | Connector M12 x 1 , 4-pin |
Core cross-section | - |
Housing material | Stainless steel 1.4305 / AISI 303 |
Sensing face | PBT |
Housing diameter | 12 mm |
Protection degree | IP67 |
General information |
Scope of delivery | 2 self locking nuts in scope of delivery |
Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 3G; 3D |