G2 flat module 2 inputs (NPN) and 2 electronic outputs
General specifications
Slave type
Standard slave
UL File Number
E87056
Indicators/operating means
LED FAULT
error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply
LED PWR
AS-Interface voltage; LED green
LED AUX
ext. auxiliary voltage UAUX ; LED green
LED IN
switching state (input); 2 LED yellow
LED OUT
Switching state (output); 2 LED yellow
Electrical specifications
Auxiliary voltage (output)
24 V DC ± 15 % PELV
Rated operating voltage
26.5 ... 31.6 V from AS-Interface
Rated operating current
≤ 40 mA (without sensors) / max. 190 mA
Protection class
III
Input
Number/Type
2 inputs for 2- or 3-wire sensors (NPN), DC alternative 1 input for 4-wire sensor (NPN), DC
Supply
from AS-Interface
Voltage
21 ... 31 V
Current loading capacity
≤ 150 mA (TB ≤ 40 В°C), ≤ 120 mA (TB ≤ 60 В°C), short-circuit protected
Input current
≤ 8 mA (limited internally)
Switching point
0 (unattenuated)
≤ 1.5 mA
1 (attenuated)
≥ 4.5 mA
Output
Number/Type
2 electronic outputs, NPN
Supply
from external auxiliary voltage UAUX
Current
1 A per output
Voltage
≥ (UAUX - 0.5 V)
Programming instructions
Profile
S-3.F
IO code
3
ID code
F
Data bits (function via AS-Interface)
inputoutput
D0
IN1-
D1
IN2-
D2
-OUT3
D3
-OUT4
Parameter bits (programmable via AS-i)
function
P0
communication monitoring P0 = 1 (basic setting), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition