63000203 - S200-M4C1-M12 - Protective switch - Quad Industry GmbH

Àðòèêóë: 63000203
Íàèìåíîâàíèå: S200-M4C1-M12 - Protective switch
Ïðîèçâîäèòåëü: Leuze electronic


Part description S200-M4C1-M12 - Protective switch
Part no. 63000203



  • Technical features

    • Basic data
      • SeriesS200
    • Characteristic parameters
      • Service life20 years, EN ISO 13849-1
      • Mechanical life time1.000.000 actuation cycles, IEC 6047-5-1
      • B10d2.000.000 number of cycles
      • Usage category at DC 13Ue 24 V, Ie 2 A, EN 60947-5-1
      • Usage category at AC 15Ue 24 V, Ie 2 A, EN 60947-5-1
    • Electrical equipment
      • Contact equipment2NC + 1NO
      • Contact openingForce-fit
      • Short circuit protected500 V, 2 A, type gG, IEC 60269-1
      • Contact protectionEarthing
      • Performance data
        • Rated insulation voltage30 V AC, 36 V DC
        • Conventional thermal current, max.2 A
    • Connection
      • Number of connections1 Piece(s)
      • Connection 1
        • Type of connectionConnector
        • FunctionContact connection
        • Thread sizeM12
        • MaterialMetal
        • No. of pins8 Piece(s)
    • Mechanical data
      • DesignCube
      • Dimension40 mm x 38 mm x 109.5 mm
      • Housing materialMetal, ZAMAK
      • Electrical contact materialSilver alloy
      • Net weight310 g
      • Housing colorRed, gray
      • Type of fasteningThrough-hole mounting
      • Switch typeInterlock device without guard interlocking, EN 1088
      • Switching principleCreep contact
      • Approach actuation directions4 x side (90°), 1 x top
      • Approach speed0 ... 0.5 m/s
      • Actuation frequency, max.3.600 per hour, IEC 6047-5-1
      • External actuatorAC-AHxx, series, straight, angled, resilient, alignable
      • Actuation force (pull-out)10 N
      • Actuating path with forced separation8.8 mm
      • Recoil tolerance4.5 mm
    • Environmental data
      • Ambient temperature, operation-25 ... 80 °C
    • Certifications
      • Protection classIP 67
      • CertificationsIMQ, CE, c UL US
      • Degree of contaminationEN 60947-1
      • Degree of contamination, external3
    • Functions
      • FunctionsLocking device without guard interlocking in acc. with EN 1088, Integration in control circuits up to category 4 in accordance with EN ISO 13849
  • Downloads

  • Part data of: 2013-11-24 21:03:00



    Íàçàä â ðàçäåë