| TIME RELAY, MOUNT. ON-DELAY 1 W, 7 TIME SETTING RANGES, 0.05 S...100 H, AC/DC 12. .240 V, WIDE RANGE SUPPLY VOLTAGE |
|
General technical data: |
product brand name | | SIRIUS |
product designation | | timing relay |
Adjustable time | s | 0.05… 360,000 |
Protection class IP | | |
| | IP40 |
| | IP20 |
Resistance against shock | | 15g / 11 ms |
Degree of pollution | | 2 |
Built in orientation | | any |
Supply voltage / strictly required / auxiliary voltage | | No |
Product function | | |
| | No |
- with auxiliary voltage / pulse-shaping
| | No |
- at the relay outputs / changeover delayed/without delay
| | No |
Product component / semi-conductor output | | No |
Product extension | | |
- optional / remote control
| | No |
- strictly required / remote control
| | No |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -40… +70 |
| °C | -25… +55 |
| °C | -40… +70 |
Relative humidity | | |
| % | 15… 85 |
EMC immunity to interference / according to IEC 60947-1 | | corresponds to degree of severity 3 |
EMC emitted interference / according to IEC 60947-1 | | IEC61000-6-3 (residential area) |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV network connection / 1 kV control connection |
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
Resistance against vibration | | 10 ... 55 Hz / 0.35 mm |
Impulse voltage resistance / rated value | V | 4,000 |
Insulation voltage / rated value | V | 300 |
Active power loss / total / typical | W | 2 |
Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | K |
- according to DIN EN 61346-2
| | K |
|
Switching Function: |
Switching function | | |
| | No |
- firmly clocked beginning with pulse
| | No |
- impuls variably clocked start with pause
| | No |
| | No |
- variably clocked start with impulse
| | No |
| | |
| | No |
| | No |
- slow-operating/instantaneous contact
| | No |
- making pulse contact/instantaneous contact
| | No |
- firmly clocked beginning with pause
| | No |
| | |
- in an additive way slow-operating
| | No |
- temporary line fault/instantaneous contact
| | No |
- without auxiliary voltage / relapse delayed
| | No |
| | Yes |
| | |
- relapse delayed/instantaneous contact
| | No |
- slow-operating/relapse delayed/instantaneous contact
| | No |
- firmly clocked beginning with pause/instantaneous contact
| | No |
Switching function / with auxiliary voltage / pulse modelling/instantaneous contact | | No |
| | |
| | No |
- slow-operating/instantaneous contact
| | No |
|
Control circuit: |
Type of voltage / of the controlled supply voltage | | AC/DC |
Control supply voltage frequency / 1 | | |
| Hz | 50 |
| Hz | 60 |
Control supply voltage / 1 | | |
| V | 12… 240 |
| V | 12… 240 |
| V | 12… 240 |
Operating range factor control supply voltage rated value / of the solenoid | | |
| | 0.85 |
| | 1.1 |
|
Auxiliary circuit: |
Operating current / of the auxiliary contacts | | |
| A | 3 |
| A | 3 |
|