6SL3225-0BH33-7UA1
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-7UA0
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-7AA1
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-7AA0
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-0UA1
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-0UA0
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-0AA1
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH33-0AA0
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH32-2UA1
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH32-2UA0
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH32-2AA1
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH32-2AA0
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-5UA1
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-5UA0
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-5AA1
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-5AA0
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-1UA1
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-1UA0
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-1AA1
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH31-1AA0
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH27-5UA1
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 11KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH27-5UA0
|
SINAMICS G120 POWER MODULE PM260 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC660-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 11KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BH27-5AA1
|
SINAMICS G120 POWER MODULE PM260 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC500-690V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 11KW FOR 140% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE37-5UA0
|
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE37-5AA0
|
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE35-5UA0
|
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE35-5AA0
|
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE34-5UA0
|
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE34-5AA0
|
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|
Siemens
|
6SL3225-0BE33-7UA0
|
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 45KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 499 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP (siemens)
|