| SIMATIC S7-300, ANALOG MODULE SM 334, OPTICALLY ISOLATED, FOR EXPANDED TEMPERATURE RANGE 4 AI/2 AO, 12 BIT 0-10 V, PT100 (CLIMAT RANGE -120 - 155 DEGR.) 20 PIN |
|
Supply voltage |
Load voltage L+ |
Rated value (DC) | 24 V |
Input current |
from load voltage L+ (without load), max. | 80 mA |
from backplane bus 5 V DC, max. | 60 mA |
Power losses |
Power loss, typ. | 2 W |
Analog inputs |
Number of analog inputs | 4 |
Number of analog inputs for voltage measurement | 2 |
Number of analog inputs for resistance measurement | 4 |
Cycle time (all channels) max. | 85 ms |
Input ranges |
Voltage | Yes |
Resistance thermometer | Yes |
Resistance | Yes |
Input ranges (rated values), voltages |
0 to +10 V | Yes |
Input resistance (0 to 10 V) | 100 kΩ |
Input ranges (rated values), resistance thermometers |
Pt 100 | Yes; only climatic range |
Input ranges (rated values), resistors |
0 to 10000 ohms | Yes |
Analog outputs |
Number of analog outputs | 2 |
Voltage output, short-circuit protection | Yes |
Voltage output, short-circuit current, max. | 10 mA |
Output ranges, voltage |
0 to 10 V | Yes |
Load impedance (in rated range of output) |
with voltage outputs, min. | 2.5 kΩ |
with voltage outputs, capacitive load, max. | 1 µF |
Cable length |
Cable length, shielded, max. | 100 m |
Analog value creation |
Integrations and conversion time/ resolution per channel |
Resolution with overrange (bit including sign), max. | 12 bit |
Integration time, ms | 85 ms |
Settling time |
for resistive load | 0.8 ms |
for capacitive load | 0.8 ms |
Encoder |
Connection of signal encoders |
for resistance measurement with 2-conductor connection | Yes |
for resistance measurement with 3-conductor connection | Yes |
for resistance measurement with 4-conductor connection | Yes |
Errors/accuracies |
Operational limit in overall temperature range |
Voltage, relative to input area | +/- 0,7 % |
Impedance, relative to input area | +/- 3,5 % |
Resistance-type thermometer, relative to input area | +/- 1 % |
Voltage, relative to output area | +/- 1 % |
Basic error limit (operational limit at 25 °C) |
Voltage, relative to input area | +/- 0,5 % |
Impedance, relative to input area | +/- 2,8 % |
Resistance-type thermometer, relative to input area | +/- 0,8 % |
Voltage, relative to output area | +/- 0,85 % |
Galvanic isolation |
Galvanic isolation analog inputs |
between the channels and the backplane bus | Yes |
Galvanic isolation analog outputs |
between the channels and the backplane bus | Yes |
Isolation |
Isolation checked with | 500 V DC |
Connection method |
required front connector | 20-pin |
Dimensions |
Width | 40 mm |
Height | 125 mm |
Depth | 120 mm |
Weight |
Weight, approx. | 200 g |
Status | Mar 12, 2012 |